NP Cement HV Genta;NP Cement LV Genta;NP Cement HV System Genta;NP Cement LV System Genta
Applicant
Cossington, Ltd.
Product Code
LOD · Orthopedic
Decision Date
Mar 5, 2015
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 888.3027
Device Class
Class 2
Attributes
Therapeutic
Intended Use
NP Cements Genta/NP Cements System Genta are intended for the fixation of prosthesis to living bone in the second stage of a two-stage revision for total joint arthroplasty after the initial infection has been cleared.
Device Story
NP Cements Genta and NP Cements System Genta are radiopaque PMMA bone cements containing gentamicin and green color additives; designed for fixation of prostheses to living bone. NP Cements Genta are supplied as powder/liquid components for manual mixing. NP Cements System Genta are supplied in a closed, syringe-like device integrating a mixing chamber and extrusion mechanism, including a vacuum tube and cannula. Used by surgeons in clinical settings during orthopedic revision procedures. The device functions by polymerizing in situ to secure prosthetic components to bone. Benefits include mechanical fixation and local antibiotic delivery to aid in the management of post-infection revision arthroplasty.
Clinical Evidence
Bench testing only. Performance data included chemical composition, thermal properties, and mechanical properties (modulus, flexural properties, static compression/bending, fatigue, fracture toughness, viscoelasticity). Biocompatibility evaluated per ISO 10993. Sterilization and shelf-life validated per international standards.
Technological Characteristics
PMMA-based bone cement containing gentamicin sulfate and barium sulfate. Components: PMMA, MMA, benzoyl peroxide, N,N-Dimethyl-p-toluidine, hydroquinone. Supplied as manual mix or integrated syringe-like delivery system. Sterilization: Gamma-ray (manual powder) or Ethylene Oxide (system powder); Filtration (liquid). Complies with FDA Class II Special Controls Guidance for PMMA Bone Cement.
Indications for Use
Indicated for patients undergoing the second stage of a two-stage revision for total joint arthroplasty following the clearance of an initial infection.
Regulatory Classification
Identification
Polymethylmethacrylate (PMMA) bone cement is a device intended to be implanted that is made from methylmethacrylate, polymethylmethacrylate, esters of methacrylic acid, or copolymers containing polymethylmethacrylate and polystyrene. The device is intended for use in arthroplastic procedures of the hip, knee, and other joints for the fixation of polymer or metallic prosthetic implants to living bone.
Special Controls
*Classification.* Class II (special controls). The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Polymethylmethacrylate (PMMA) Bone Cement.”
K242216 — GENTAFIX® (1, 3, 3MV) · Teknimed Sas · Dec 18, 2024
K092773 — CEMEX GENTA, GENTA SYSTEM AND GENTA SYSTEM FAST · Tecres S.P.A. · Nov 24, 2009
K033596 — CEMEX GENTA BONE CEMENT; CEMEX GENTA SYSTEM BONE CEMENT · Exactech, Inc. · May 10, 2004
K043403 — CEMEX SYSTEM GENTA FAST BONE CEMENT · Exactech, Inc. · Dec 28, 2004
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is a stylized image of three human profiles facing to the right, stacked on top of each other. The profiles are rendered in a simple, line-art style.
Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002
March 5. 2015
Cossington Limited % Diane Mandell Horwitz, Ph.D. Mandell Horwitz Consultants, LLC 2995 Steven Martin Drive Fairfax, Virginia 22031
Re: K143100
Trade/Device Name: NP Cements Genta / NP Cement System Genta Regulation Number: 21 CFR 888.3027 Regulation Name: Polymethylmethacrylate (PMMA) bone cement Regulatory Class: Class II Product Code: LOD, MBB Dated: January 23, 2015 Received: January 23, 2015
Dear Dr. Horwitz:
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug. and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set
{1}------------------------------------------------
Page 2 - Diane Mandell Horwitz, Ph.D.
forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address
http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm.
Sincerely vours.
Mark N. Melkerson -S
Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
## 4.0 Indications for Use
### DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration
## Indications for Use
510(k) Number (if known)
K143100
Device Name NP Cements Genta / NP Cement System Genta
Indications for Use (Describe)
NP Cements Genta / NP Cement System Genta are intended for the fixation of prosthesis to living bone in the second stage of a two-stage revision for total joint arthroplasty after the initial infection has been cleared.
Type of Use (Select one or both, as applicable)
2 Prescription Use (Part 21 CFR 801 Subpart D)
Over-The-Counter Use (21 CFR 801 Subpart C)
PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED.
### FOR FDA USE ONLY
Concurrence of Center for Devices and Radiological Health (CDRH) (Signature)
This section applies only to requirements of the Paperwork Reduction Act of 1995,
### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW."
The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to:
> Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov
"An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number."
FORM FDA 3881 (1/14)
PSC" Pablishing Survices (301) 447-6740 EJ
Form Approved: OMB No, 0910-0120 Expiration Date: January 31, 2017 See PRA Statement below.
{3}------------------------------------------------
# 510(k) SUMMARY OF SAFETY AND EFFECTIVENESS
#### GENERAL INFORMATION 1
#### Submitter and Owner of the 510(k) 1.1
Cossington Ltd 1 Princeton Mews Kingston Upon Thames Surrey KT2 6PT United Kingdom
#### Official Correspondent 1.2
Diane Mandell Horwitz, PhD, RAC Regulatory affairs Consultants Mandell Horwitz Consultants, LLC 2995 Steven Martin Drive Fairfax, Virginia 20031
Telephone: (703) 307-2921 Fax: (703) 242-1117 E-mail: dmh@mandellhorwitzconsulting.com
#### 1.3 Devices Subject of this 510(k)
NP Cements Genta - Low and High Viscosity NP Cements System Genta- Low and High Viscosity
#### 1.4 Date of Preparation
October 16, 2014
#### NAME OF THE DEVICE AND CLASSIFICATION INFORMATION 2
This traditional 510(k) has been submitted for the following devices.
- NP Cements Genta - Low and High Viscosity
- NP Cements System Genta Low and High Viscosity ●
#### 2.1 Trade/Proprietary Name
As of the date of this application, the Sponsor has not yet developed a trade name for the new bone cements.
{4}------------------------------------------------
#### 2.2 Common/Usual Name
PMMA bone cement with antibiotic for orthopedics PMMA bone cement with antibiotic for orthopedics within a syringe-like device system
#### 2.3 Classification Information
| Classification Name: | Polymethylmethacrylate (PMMA) Bone Cement |
|----------------------------|-----------------------------------------------------|
| Classification Regulation: | 21 CFR § 888.3027 |
| Regulatory Class: | Class II |
| Product Code: | LOD – Bone Cement<br>MBB – Bone Cement, Antibiotics |
| Panel: | Orthopedic |
#### PREDICATE DEVICE 3
The predicate device is as follows:
- Tecres Cemex Genta HV, which was cleared originally through 510(k) application . K033596 and then subsequently through 510(k) application K092773.
#### DEVICE DESCRIPTION ব
The NP Cements Genta and NP Cements System Genta are PMMA, radiopaque bone cements, containing gentamicin and color additives to impart a green color, designed for the fixation of prosthesis to the living bone. The devices contain the same individual chemical constituents, but are supplied in different ways:
- 1. NP Cements Genta are a traditional bone cement product. The liquid is contained in a vial and the powder in a sachet; these components are packaged in unitary blister with Tyvek lid, which is placed in an aluminum bag. The components are manually mixed immediately prior to use.
- 2. NP Cements System Genta stores the powder and liquid components separately within a closed syringe-like device that serve as both mixing chamber and extrusion device. The device is provided with a vacuum tube and a cannula with the pusher rod. The product is packaged in a double blister, the external blister is sealed with a Tyyek lid, and then placed in an aluminum bag.
The devices are sold disposable and sterile. The NP Cements Genta are available in a low and high viscosity version. The NP Cements System Genta are also available in a low and high viscosity version.
{5}------------------------------------------------
# 5 INDICATIONS FOR USE
Below is the indication for use for each bone cement.
NP Cements Genta/NP Cements System Genta are intended for the fixation of prosthesis to living bone in the second stage of a two-stage revision for total joint arthroplasty after the initial infection has been cleared.
#### COMPARISON OF THE INTENDED USE WITH THE PREDICATE DEVICE く
The NP Cements Genta and the NP Cements System Genta have the same indication for use statements (other than the identification of the trade name) as the predicate device, and thus have the same intended use, as shown in Table 1.
| Device | Indication for Use |
|-----------------------------------------------------------|----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Cossington<br>NP Cement Genta /<br>NP Cement System Genta | NP Cements Genta/NP Cements System Genta are intended for the fixation of<br>prosthesis to living bone in the second stage of a two-stage revision for total joint<br>arthroplasty after the initial infection has been cleared. |
| Tecres Cemex Genta HV<br>(K033596 and K092773) | Cemex Genta HV is intended for the fixation of prosthesis to living bone in the<br>second stage of a two-stage revision for total joint arthroplasty after the initial<br>infection has been cleared. |
| | | Table 1: Comparison of the Indication Statement with the Predicate Device |
|--|--|---------------------------------------------------------------------------|
| | | |
### 7 COMPARISON OF THE TECHNOLOGICAL CHARACTERISTICS WITH THE PREDICATE DEVICE
The NP Cements Genta and NP Cements System Genta share many of the same technological characteristics compared to the predicate Cemex Genta HV, including important considerations such as the same materials, and mechanical and chemical-physical performances. There are, however, some differences in the shelf life, method of sterilization of the powder component, the presence of colored pigments and how the device is supplied to the surgeon for the system version. These comparisons are summarized in Table 2.
| Characteristics | Cossington<br>NP Cements Genta<br>NP Cements System Genta | Tecres<br>Cemex Genta HV<br>K033596 and K092773 | Comparison |
|------------------|--------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------|------------|
| Main Components | Polymethylmethacrylate<br>(PMMA)<br>Methylmethacrylate (MMA)<br>Gentamicin Sulphate<br>Barium Sulphate | Polymethylmethacrylate<br>(PMMA)<br>Methylmethacrylate (MMA)<br>Gentamicin Sulphate<br>Barium Sulphate | Same |
| Other Components | Benzoyl peroxide<br>N,N-Dimethyl-p-toluidine<br>Hydroquinone | Benzoyl peroxide<br>N,N-Dimethyl-p-toluidine<br>Hydroquinone | Same |
| Coloring Agents | Pigments | None | Different |
# Table 2: Comparison of the Technological Characteristics with the Predicate Device
{6}------------------------------------------------
| Characteristics | Cossington<br>NP Cements Genta<br>NP Cements System Genta | Tecres<br>Cemex Genta HV<br>K033596 and K092773 | Comparison |
|------------------------------------------------|-----------------------------------------------------------|-------------------------------------------------|---------------------------------------------|
| Mixing/Application | Manual<br>Syringe-like device (System<br>version) | Manual | Same for manual:<br>different for<br>system |
| Powder Sterilization<br>Method | Gamma-ray irradiation (manual)<br>Ethylene oxide (system) | Ethylene Oxide | Same for manual:<br>different for<br>system |
| Sterility Assurance<br>Level (SAL) -<br>Powder | 10-6 | 10-6 | Same |
| Liquid Sterilization<br>Method | Filtration | Filtration | Same |
| SAL - Liquid | 10-3 | 10-3 | Same |
| Shelf Life | 2 years | 5 years | Different |
# 8 PERFORMANCE DATA
This 510(k) submission provided performance data to establish the substantial equivalence of the new bone cements to the predicate bone cement. Performance testing was conducted in accordance with the "FDA Class II Special Controls Guidance Document: Polymethylmethacrylate (PMMA) Bone Cement; Guidance for Industry and FDA" dated July 17, 2002. The following is a summary of the performance data.
Sterilization and Shelf Life: The devices are sterilized using standard methods and the sterilization cycles have been validated following international standards. The shelf life of the devices has been established in ongoing stability studies.
Biocompatibility: Biocompatibility testing of the NP Cements Genta and NP Cements System Genta has been performed to show the device materials are safe, biocompatible and suitable for their intended use. Both ISO 10993 and FDA Draft Guidance "Use of International Standard ISO 10993. Biological Evaluation of Medical Devices Part 1: Evaluation and Testing" have been taken into account to evaluate the biocompatibility of the device materials.
Performance Testing (Chemical, Material and Mechanical): Performance testing was performed to characterize the bone cements in accordance with special controls guidance document. This testing included the following:
- Mixing and application characteristics (e.g., dough time, setting time)
- Chemical composition (e.g., residuals, molecular weight and polymer structure, glass . transition temperature)
- Thermal properties (e.g., polymerization temperature) ●
- . Mechanical properties (e.g., modulus and flexural properties, static compression and bending, fatigue testing, fracture toughness and viscoelasticity)
{7}------------------------------------------------
The performance data demonstrate that the new devices are substantially equivalent to the predicate device, and meet the requirements of the Special Controls Guidance document.
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.