Miscellaneous
QHG
Defect Measurement Tool
2
Product Code
NQO
Prosthesis, Spinous Process Spacer/Plate
3
Product Code
HTM
Stimulator, Osteogenesis, Electric, Battery-Operated, Invasive
3
Product Code
HWF
Prosthesis, Ligament
3
Product Code
LML
Ligaments And Tendons, Synthetic
3
Product Code
LMN
Ceramics, Calcium Triphosphate/Hydroxypatite, Non-Load Bearing Uses
3
Product Code
LOE
Stimulator, Invasive Bone Growth
3
Product Code
LOF
Stimulator, Bone Growth, Non-Invasive
3
Product Code
LPF
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic, Cemented
3
Product Code
LPQ
Stimulator, Ultrasound And Muscle, For Use Other Than Applying Therapeutic Deep
3
Product Code
LWA
Prosthesis, Ligament, Ptfe
3
Product Code
LXC
Monitor, Pressure, Intracompartmental
U
Product Code
LXY
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Polymer/Metal/Polymer
3
Product Code
LZJ
Prosthesis, Toe (Metatarsophalangeal), Joint, Metal/Polymer, Semi-Constrained
U
Product Code
MBD
Prosthesis, Knee, Patello/Femorotibial, Unconstrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
3
Product Code
MBJ
Fastener, Fixation, Biodegradable, Hard Tissue
3
Product Code
MBS
Filler, Bone Void, Non-Osteoinduction
3
Product Code
MCV
Spinal Pedicle Screw, Fixation, Appliance System
3
Product Code
MDI
Prosthesis, Rib Replacement
U
Product Code
MJO
Prosthesis, Intervertebral Disc
3
Product Code
MJT
Prosthesis, Shoulder, Humeral (Bipolar Hemi-Shoulder) Metal/Polymer, Cemented Or Uncemented
3
Product Code
MOZ
Acid, Hyaluronic, Intraarticular
3
Product Code
MPK
Semi-Constrained Metal/Polymer Finger Joint Prosthesis
F
Product Code
MPW
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction
3
Product Code
MQO
Prosthetic Disc Nucleus Device
N
Product Code
MRA
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic/Metal, Cemented Or Uncemented
3
Product Code
MRW
System, Facet Screw Spinal Device
U
Product Code
NBN
Generator, Shock-Wave, For Pain Relief
3
Product Code
NCO
Implant, Cartilage, For Articular Cartilage Repair
3
Product Code
NEG
Finger Semi-Constrained Pyrolytic Carbon Uncemented Prosthesis
3
Product Code
NEK
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold With Metal Prosthesis, Osteoinduction
3
Product Code
NJL
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Metal/Polymer, Mobile Bearing
3
Product Code
NOX
Filler, Bone Void, Synthetic Peptide
3
Product Code
NRA
Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing
3
Product Code
NTG
Prosthesis, Ankle, Uncemented, Non-Constrained
3
Product Code
NVR
Intervertebral Fusion Device With Bone Graft, Solid-Sphere, Lumbar
U
Product Code
NXT
Prosthesis, Hip, Semi-Constrained, Metal/Metal, Resurfacing
3
Product Code
OJZ
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction - Hde
F
Product Code
OKD
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction - Hde, Long Bone Nonunion
F
Product Code
OME
Extracorporeal Shock Wave Treatment
3
Product Code
OMX
High Demand, Revision, Semi-Constrained, Pyrolytic Carbon, Uncemented Finger Prosthesis
F
Product Code
OVO
Prosthesis, Hip, Semi-Constrained, Ceramic-On-Metal Articulation
3
Product Code
OYR
Filler, Bone Void, Recombinant Platelet-Derived Growth Factor
N
Product Code
PBU
Bone Void Filler, Syringe
N
Product Code
PFM
Hemibridge System
N
Product Code
PGM
Growing Rod System
U
Product Code
PGN
Growing Rod System- Magnetic Actuation
U
Product Code
PIX
Elbow Joint Metal/Polymer, Constrained, Porous Coated, Uncemented Prosthesis
N
Product Code
PJY
Osseoanchored Prostheses For The Rehabilitation Of Transfemoral Amputees
3
Product Code
PNW
Prosthesis, Metatarsophalangeal Joint Cartilage Replacement Implant
3
Product Code
PWG
Spinal Fixation System
N
Product Code
QCG
Filler, Bone Void, Calcium Compound, Lower Extremity Use, Use On Bone Marrow Lesions
N
Product Code
QES
Reherniation Reduction Device
3
Product Code
QGP
Posterior Ratcheting Rod System
N
Product Code
QHP
Vertebral Body Tethering System
N
Product Code
QNN
Talus Spacer
F
Product Code
QRR
Filler, Bone Void, Calcium Compound Containing Gentamicin
2
Product Code
QJD
Absorbable Metallic Bone Fixation Fastener
2
Product Code
QKW
Shoulder Joint Humeral (Hemi-Shoulder) Ceramic Head/Metallic Stem Cemented Or Uncemented Prosthesis
2
Product Code
QVV
Medial Knee Implanted Shock Absorber
2
Product Code
QWL
Intraoperative Surgical Angle Measurement Tool
2
Product Code
QRU
Implant, Resorbable, For Articular Osteochondral Repair
3
Product Code
QWK
Prosthesis, Posterior Spinal Elements
3
Product Code
QYQ
Prosthesis, Total Talus Replacement With Soft Tissue Attachment Sites, Metal
F
Product Code
QZO
Wearable Vibration Device For Orthopedic Use
2
Product Code
QZY
Spinal Fusion Device With Quaternary Ammonium Compound Coating
2
Product Code
QZZ
Limb And Joint Salvage Device With Coating For Bacteria Reduction
2
Product Code
QVL
Absorbable Gel For Intraoperative Use In Spine Surgery
2
Product Code
SFA
Prosthesis, Finger, Semi-Constrained, Metal/Polymer
3
Product Code
Submissions with No Product Code
Miscellaneous
K
25
2846
TaperSet™ Hip System
Cleared 510(K)
K
25
2020
TunnelVision Endoscopic Soft Tissue Release System and the HBL Blade Assembly
Cleared 510(K)
K
25
2221
Inset Reverse Total Shoulder System
Cleared 510(K)
K
24
2237
Jewel Soft Tissue Reinforcement Device (102-6005)
Cleared 510(K)
K
24
3461
Calibrate Interbody Systems
Cleared 510(K)
K
24
2307
ACHIEVE Partial Knee System
Cleared 510(K)
K
24
2272
CORIOGRAPH Pre-Op Planning and Modeling Services
Cleared 510(K)
K
86
4488
SWANSON TITANIUM CONDYLAR IMPLANT
Cleared 510(K)
K
87
0213
MODIFIED PROFILE FEMORAL HIP
Cleared 510(K)
K
87
0174
MCCUTCHEN FEMORAL HIP PROSTHESIS
Cleared 510(K)
P
83
0055
LCS® Total Knee System
OK30
PMA Approval
P
96
0047
HOWMEDICA OSTEONICS CONSTRAINED ACETABULAR INSERT & TRIDENT CONSTRAINED ACETABULAR INSERT
APPR
PMA Approval
P
97
0015
INTERFIX THREADED FUSION DEVICE
APPR
PMA Approval
P
97
0015
INTER FIX THREADED FUSION DEVICE
APPR
PMA Approval
P
97
0015
INTER FIX III THREADED FUSION DEVICE
APPR
PMA Approval
P
96
0047
OSTEONICS CONSTRAINED ACETABULAR INSERT
APPR
PMA Approval
P
97
0015
INTER FIX RP THREADED FUSION DEVICE
APPR
PMA Approval
P
97
0015
INTER FIX THREADED FUSION DEVICE
APPR
PMA Approval
P
97
0015
INTER FIX RP THREADED FUSION DEVICE
APPR
PMA Approval
P
97
0015
INTER FIX THREADED FUSION DEVICE
APPR
PMA Approval
P
97
0015
NOVUS TM LC THREADED INTERBODY FUSION DEVICE (TIBFD)
APPR
PMA Approval
P
97
0015
NOVUS (TM) LC INTERBODY FUSION DEVICE
APPR
PMA Approval
P
96
0047
OSTEONICS CONSTRAINED ACETABULAR INSERT
APPR
PMA Approval
K
86
2755
DUNN ANTERIOR DISTRACTION SYSTEM
Cleared 510(K)
K
86
4331
TRI-LOCK LONG STEM MODULAR NECK
Cleared 510(K)
K
86
4788
EXACTECH TOTAL HIP INSTRUMENTS
Cleared 510(K)
K
86
3271
FASCICULATED S ROD
Cleared 510(K)
K
86
3239
FASCICULATED BOAT ROD
Cleared 510(K)
K
86
3215
FASCICULATED I ROD
Cleared 510(K)
K
86
4631
MOORE'S STRAIGHT & THOMPSON'S CURVED STEM PROSTHE.
Cleared 510(K)
K
86
4337
SEGMENTAL SPINAL INSTRUMENTATION SYSTEM
Cleared 510(K)
K
86
4508
HOWSE II TOTAL HIP REPLACEMENT SYSTEM
Cleared 510(K)
K
86
4372
OSTEONICS MC1 METAL-BACK ACETABULAR CUP/PMMA SPACE
Cleared 510(K)
K
86
4423
RAYLOR(TM) OSTEOTOMES
Cleared 510(K)
K
86
4340
WILLIAMS ORTHOPAEDIC SURGICAL INSTRUMENTS
Cleared 510(K)
K
86
3896
AUSTIN MOORE HIP PROSTHESIS
Cleared 510(K)
K
86
3854
P.M.D. INTRAMEDULLARY CEMENT RESTRICTOR PLUG
Cleared 510(K)
K
86
3554
THACKRAY CRUCIATE SPARING KNEE CS-1
Cleared 510(K)
K
86
3528
BICONDYLAR TOE PROSTHESIS
Cleared 510(K)
K
86
2157
OMC ORTHOMET CANNULATED SCREW
Cleared 510(K)
K
86
2945
DOWNS SURGICAL TITANIUM AUTOCOMPRESSION PLATES
Cleared 510(K)
K
86
1183
INTRAMEDULLARY ROD
Cleared 510(K)
K
86
2752
C.S.M. HIP
Cleared 510(K)
K
86
1826
KIRSCHNER PROXIMAL FEMUR TOTAL HIP SYSTEM
Cleared 510(K)
K
86
1450
SCHURMAN/CARTER HIP PROSTHESIS POROUS COATED
Cleared 510(K)
K
86
0207
S-ROM 135 POROUS COATED FEMORAL STEM COLLAR
Cleared 510(K)
K
86
0163
BICONDYLAR TOE PROSTHESIS
Cleared 510(K)
K
86
1292
CASTALERT
Cleared 510(K)
K
86
1043
SPINAL EXCURSION METER
Cleared 510(K)
K
85
4621
ISOSTATION KNEE MACHINE (K-100)
Cleared 510(K)
K
85
4943
OMKNEE SYSTEM, POROUS COATED
Cleared 510(K)
K
85
5148
THARIES FIBER
Cleared 510(K)
K
85
2137
FENLIN TOTAL SHOULDER
Cleared 510(K)
K
86
0074
SCHULTZ METACARPOPHALANGEAL JOINT PROSTHESIS
Cleared 510(K)
K
85
5123
KMW HIP PROSTHESIS POROUS COATED
Cleared 510(K)
K
85
1864
SPINAL STABILIZING UNIT
Cleared 510(K)
K
85
1409
UNILOC TOTAL HIP PROSTHESIS
Cleared 510(K)
K
85
4248
GOODLEY POLYAXIAL CERVICAL TRACTION UNIT
Cleared 510(K)
K
85
4191
MECRON UNCEMENTED STRUCTURED STEM HIP
Cleared 510(K)
K
85
3437
H-H HUNTER TENDON ROD
Cleared 510(K)
K
85
3764
TENDON LEADER
Cleared 510(K)
K
85
3205
PROXIMAL POROCOAT MODIFIED MEDICAL ASPECT AML HIP
Cleared 510(K)
K
85
0255
DOW CORNING WRIGHT TITANIUM WRIST JOINT GROMMET
Cleared 510(K)
K
85
1206
SHOULDER-HOLDER
Cleared 510(K)
K
84
3013
H-H TENDEON IMPLANT
Cleared 510(K)
K
84
3778
MAYO ELBOW II
Cleared 510(K)
K
84
2626
HIP PROSTHESIS PACK
Cleared 510(K)
K
84
1517
CLOUTIER II TOTAL KNEE W/BEADED SURF
Cleared 510(K)
K
84
0271
CEMENTLESS HIP PROSTHESIS
Cleared 510(K)
K
84
1022
SRC TOTAL KNEE
Cleared 510(K)
K
84
1300
ANTRUM NEEDLE-WOLF TYPE
Cleared 510(K)
K
84
1125
HUCKSTEPS STAPLES
Cleared 510(K)
K
83
3461
HS4 HEAD/NECK FEMORAL PROSTHESES
Cleared 510(K)
K
83
2740
FEMORAL FRACTURE ORTHOSIS
Cleared 510(K)
K
83
1708
MICRO-STRUCTURED SURFACE HIP PROSTHESIS
Cleared 510(K)
K
83
1426
ORTHOPEDIC/NALEBUFF FINGER INSTRUMENTS
Cleared 510(K)
K
82
3059
DOSIMETRY RELEASE OF RADIATION STERIL.
Cleared 510(K)
K
82
0218
PRE-STERILIZATION OF VITALLIUM ALLOY
Cleared 510(K)
K
82
0899
MECRON VOORHOEVE TITANIUM SHEATH
Cleared 510(K)
K
82
0958
DIGILOG SYSTEM
Cleared 510(K)
K
82
0719
THE ICR KNEE
Cleared 510(K)
K
81
3094
ACETABULAR CEMENT COMPRESSOR
Cleared 510(K)
K
81
2440
POWER PACK
Cleared 510(K)
K
81
2439
DUAL MPC CHARGER
Cleared 510(K)
K
81
1961
VISITEC NEEDLE RANGE (ORTHOPAEDIC)
Cleared 510(K)
K
81
1119
WEBER/STUEHMER HIP JOINT ENDOPROSTHESIS
Cleared 510(K)
K
81
1201
EFTEKHAR ACETABULAR STANDOFF
Cleared 510(K)
K
81
0644
HOFFMAN HOOP DEVICE
Cleared 510(K)
K
81
0518
CAST HIPPED VITALLIUM
Cleared 510(K)
K
80
3093
SLIT CATHETER SYSTEM
Cleared 510(K)
K
80
3029
TLC SUPPORT PRODUCTS
Cleared 510(K)
K
80
2106
LEWIS TRAPEZO METACARPAL PROSTHESIS
Cleared 510(K)
K
80
1934
WORRELL PATELLA FEMORAL SHIELD
Cleared 510(K)
K
80
1313
COMPRESSION MOLDING OF UHMWPE
Cleared 510(K)
K
80
0948
DOODLE BRUSH
Cleared 510(K)
K
79
1757
CERVICAL ORTHOPEDIC PILLOW
Cleared 510(K)
K
78
1937
PROTHESIS, METACARPAL
Cleared 510(K)
K
78
1343
RESURFACE PROSHESIS
Cleared 510(K)
K
78
1135
INGROWN TOENAIL APPLIANCE, OR
Cleared 510(K)
K
78
1112
CAST WEDGE, YANCEY
Cleared 510(K)
K
77
0856
PROSTHESIS, TRAPEZIUM & TRAPEZIUM TRIAL
Cleared 510(K)
K
77
0501
KNEE CUFF FOR EXPRESSING FLUID
Cleared 510(K)
K
77
0124
PRE-ROLLED IMPERVIOUS STOCKINETTE
Cleared 510(K)
K
77
0079
KESSELL TOTAL SHOULDER
Cleared 510(K)
K
76
1222
BENZOIN ISOBUTYL ETHER
Cleared 510(K)
K
76
1092
INGUINAL COMPRESSIVE DEVICE (ICD)
Cleared 510(K)
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
Subpart E—Neurological Surgical Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
OR
/
OR-misc
/
no-product-code
/
K854621
View Source
ISOSTATION KNEE MACHINE (K-100)
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K854621
510(k) Type
Traditional
Applicant
ISOTECHNOLOGIES, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
3/7/1986
Days to Decision
109 days
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Miscellaneous
QHG
Defect Measurement Tool
NQO
Prosthesis, Spinous Process Spacer/Plate
HTM
Stimulator, Osteogenesis, Electric, Battery-Operated, Invasive
HWF
Prosthesis, Ligament
LML
Ligaments And Tendons, Synthetic
LMN
Ceramics, Calcium Triphosphate/Hydroxypatite, Non-Load Bearing Uses
LOE
Stimulator, Invasive Bone Growth
LOF
Stimulator, Bone Growth, Non-Invasive
LPF
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic, Cemented
LPQ
Stimulator, Ultrasound And Muscle, For Use Other Than Applying Therapeutic Deep
LWA
Prosthesis, Ligament, Ptfe
LXC
Monitor, Pressure, Intracompartmental
LXY
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Polymer/Metal/Polymer
LZJ
Prosthesis, Toe (Metatarsophalangeal), Joint, Metal/Polymer, Semi-Constrained
MBD
Prosthesis, Knee, Patello/Femorotibial, Unconstrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
MBJ
Fastener, Fixation, Biodegradable, Hard Tissue
MBS
Filler, Bone Void, Non-Osteoinduction
MCV
Spinal Pedicle Screw, Fixation, Appliance System
MDI
Prosthesis, Rib Replacement
MJO
Prosthesis, Intervertebral Disc
MJT
Prosthesis, Shoulder, Humeral (Bipolar Hemi-Shoulder) Metal/Polymer, Cemented Or Uncemented
MOZ
Acid, Hyaluronic, Intraarticular
MPK
Semi-Constrained Metal/Polymer Finger Joint Prosthesis
MPW
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction
MQO
Prosthetic Disc Nucleus Device
MRA
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic/Metal, Cemented Or Uncemented
MRW
System, Facet Screw Spinal Device
NBN
Generator, Shock-Wave, For Pain Relief
NCO
Implant, Cartilage, For Articular Cartilage Repair
NEG
Finger Semi-Constrained Pyrolytic Carbon Uncemented Prosthesis
NEK
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold With Metal Prosthesis, Osteoinduction
NJL
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Metal/Polymer, Mobile Bearing
NOX
Filler, Bone Void, Synthetic Peptide
NRA
Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing
NTG
Prosthesis, Ankle, Uncemented, Non-Constrained
NVR
Intervertebral Fusion Device With Bone Graft, Solid-Sphere, Lumbar
NXT
Prosthesis, Hip, Semi-Constrained, Metal/Metal, Resurfacing
OJZ
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction - Hde
OKD
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction - Hde, Long Bone Nonunion
OME
Extracorporeal Shock Wave Treatment
OMX
High Demand, Revision, Semi-Constrained, Pyrolytic Carbon, Uncemented Finger Prosthesis
OVO
Prosthesis, Hip, Semi-Constrained, Ceramic-On-Metal Articulation
OYR
Filler, Bone Void, Recombinant Platelet-Derived Growth Factor
PBU
Bone Void Filler, Syringe
PFM
Hemibridge System
PGM
Growing Rod System
PGN
Growing Rod System- Magnetic Actuation
PIX
Elbow Joint Metal/Polymer, Constrained, Porous Coated, Uncemented Prosthesis
PJY
Osseoanchored Prostheses For The Rehabilitation Of Transfemoral Amputees
PNW
Prosthesis, Metatarsophalangeal Joint Cartilage Replacement Implant
PWG
Spinal Fixation System
QCG
Filler, Bone Void, Calcium Compound, Lower Extremity Use, Use On Bone Marrow Lesions
QES
Reherniation Reduction Device
QGP
Posterior Ratcheting Rod System
QHP
Vertebral Body Tethering System
QNN
Talus Spacer
QRR
Filler, Bone Void, Calcium Compound Containing Gentamicin
QJD
Absorbable Metallic Bone Fixation Fastener
QKW
Shoulder Joint Humeral (Hemi-Shoulder) Ceramic Head/Metallic Stem Cemented Or Uncemented Prosthesis
QVV
Medial Knee Implanted Shock Absorber
QWL
Intraoperative Surgical Angle Measurement Tool
QRU
Implant, Resorbable, For Articular Osteochondral Repair
QWK
Prosthesis, Posterior Spinal Elements
QYQ
Prosthesis, Total Talus Replacement With Soft Tissue Attachment Sites, Metal
QZO
Wearable Vibration Device For Orthopedic Use
QZY
Spinal Fusion Device With Quaternary Ammonium Compound Coating
QZZ
Limb And Joint Salvage Device With Coating For Bacteria Reduction
QVL
Absorbable Gel For Intraoperative Use In Spine Surgery
SFA
Prosthesis, Finger, Semi-Constrained, Metal/Polymer
Submissions with No Product Code
K
25
2846
TaperSet™ Hip System
K
25
2020
TunnelVision Endoscopic Soft Tissue Release System and the HBL Blade Assembly
K
25
2221
Inset Reverse Total Shoulder System
K
24
2237
Jewel Soft Tissue Reinforcement Device (102-6005)
K
24
3461
Calibrate Interbody Systems
K
24
2307
ACHIEVE Partial Knee System
K
24
2272
CORIOGRAPH Pre-Op Planning and Modeling Services
K
86
4488
SWANSON TITANIUM CONDYLAR IMPLANT
K
87
0213
MODIFIED PROFILE FEMORAL HIP
K
87
0174
MCCUTCHEN FEMORAL HIP PROSTHESIS
P
83
0055
LCS® Total Knee System
P
96
0047
HOWMEDICA OSTEONICS CONSTRAINED ACETABULAR INSERT & TRIDENT CONSTRAINED ACETABULAR INSERT
P
97
0015
INTERFIX THREADED FUSION DEVICE
P
97
0015
INTER FIX THREADED FUSION DEVICE
P
97
0015
INTER FIX III THREADED FUSION DEVICE
P
96
0047
OSTEONICS CONSTRAINED ACETABULAR INSERT
P
97
0015
INTER FIX RP THREADED FUSION DEVICE
P
97
0015
INTER FIX THREADED FUSION DEVICE
P
97
0015
INTER FIX RP THREADED FUSION DEVICE
P
97
0015
INTER FIX THREADED FUSION DEVICE
P
97
0015
NOVUS TM LC THREADED INTERBODY FUSION DEVICE (TIBFD)
P
97
0015
NOVUS (TM) LC INTERBODY FUSION DEVICE
P
96
0047
OSTEONICS CONSTRAINED ACETABULAR INSERT
K
86
2755
DUNN ANTERIOR DISTRACTION SYSTEM
K
86
4331
TRI-LOCK LONG STEM MODULAR NECK
K
86
4788
EXACTECH TOTAL HIP INSTRUMENTS
K
86
3271
FASCICULATED S ROD
K
86
3239
FASCICULATED BOAT ROD
K
86
3215
FASCICULATED I ROD
K
86
4631
MOORE'S STRAIGHT & THOMPSON'S CURVED STEM PROSTHE.
K
86
4337
SEGMENTAL SPINAL INSTRUMENTATION SYSTEM
K
86
4508
HOWSE II TOTAL HIP REPLACEMENT SYSTEM
K
86
4372
OSTEONICS MC1 METAL-BACK ACETABULAR CUP/PMMA SPACE
K
86
4423
RAYLOR(TM) OSTEOTOMES
K
86
4340
WILLIAMS ORTHOPAEDIC SURGICAL INSTRUMENTS
K
86
3896
AUSTIN MOORE HIP PROSTHESIS
K
86
3854
P.M.D. INTRAMEDULLARY CEMENT RESTRICTOR PLUG
K
86
3554
THACKRAY CRUCIATE SPARING KNEE CS-1
K
86
3528
BICONDYLAR TOE PROSTHESIS
K
86
2157
OMC ORTHOMET CANNULATED SCREW
K
86
2945
DOWNS SURGICAL TITANIUM AUTOCOMPRESSION PLATES
K
86
1183
INTRAMEDULLARY ROD
K
86
2752
C.S.M. HIP
K
86
1826
KIRSCHNER PROXIMAL FEMUR TOTAL HIP SYSTEM
K
86
1450
SCHURMAN/CARTER HIP PROSTHESIS POROUS COATED
K
86
0207
S-ROM 135 POROUS COATED FEMORAL STEM COLLAR
K
86
0163
BICONDYLAR TOE PROSTHESIS
K
86
1292
CASTALERT
K
86
1043
SPINAL EXCURSION METER
K
85
4621
ISOSTATION KNEE MACHINE (K-100)
K
85
4943
OMKNEE SYSTEM, POROUS COATED
K
85
5148
THARIES FIBER
K
85
2137
FENLIN TOTAL SHOULDER
K
86
0074
SCHULTZ METACARPOPHALANGEAL JOINT PROSTHESIS
K
85
5123
KMW HIP PROSTHESIS POROUS COATED
K
85
1864
SPINAL STABILIZING UNIT
K
85
1409
UNILOC TOTAL HIP PROSTHESIS
K
85
4248
GOODLEY POLYAXIAL CERVICAL TRACTION UNIT
K
85
4191
MECRON UNCEMENTED STRUCTURED STEM HIP
K
85
3437
H-H HUNTER TENDON ROD
K
85
3764
TENDON LEADER
K
85
3205
PROXIMAL POROCOAT MODIFIED MEDICAL ASPECT AML HIP
K
85
0255
DOW CORNING WRIGHT TITANIUM WRIST JOINT GROMMET
K
85
1206
SHOULDER-HOLDER
K
84
3013
H-H TENDEON IMPLANT
K
84
3778
MAYO ELBOW II
K
84
2626
HIP PROSTHESIS PACK
K
84
1517
CLOUTIER II TOTAL KNEE W/BEADED SURF
K
84
0271
CEMENTLESS HIP PROSTHESIS
K
84
1022
SRC TOTAL KNEE
K
84
1300
ANTRUM NEEDLE-WOLF TYPE
K
84
1125
HUCKSTEPS STAPLES
K
83
3461
HS4 HEAD/NECK FEMORAL PROSTHESES
K
83
2740
FEMORAL FRACTURE ORTHOSIS
K
83
1708
MICRO-STRUCTURED SURFACE HIP PROSTHESIS
K
83
1426
ORTHOPEDIC/NALEBUFF FINGER INSTRUMENTS
K
82
3059
DOSIMETRY RELEASE OF RADIATION STERIL.
K
82
0218
PRE-STERILIZATION OF VITALLIUM ALLOY
K
82
0899
MECRON VOORHOEVE TITANIUM SHEATH
K
82
0958
DIGILOG SYSTEM
K
82
0719
THE ICR KNEE
K
81
3094
ACETABULAR CEMENT COMPRESSOR
K
81
2440
POWER PACK
K
81
2439
DUAL MPC CHARGER
K
81
1961
VISITEC NEEDLE RANGE (ORTHOPAEDIC)
K
81
1119
WEBER/STUEHMER HIP JOINT ENDOPROSTHESIS
K
81
1201
EFTEKHAR ACETABULAR STANDOFF
K
81
0644
HOFFMAN HOOP DEVICE
K
81
0518
CAST HIPPED VITALLIUM
K
80
3093
SLIT CATHETER SYSTEM
K
80
3029
TLC SUPPORT PRODUCTS
K
80
2106
LEWIS TRAPEZO METACARPAL PROSTHESIS
K
80
1934
WORRELL PATELLA FEMORAL SHIELD
K
80
1313
COMPRESSION MOLDING OF UHMWPE
K
80
0948
DOODLE BRUSH
K
79
1757
CERVICAL ORTHOPEDIC PILLOW
K
78
1937
PROTHESIS, METACARPAL
K
78
1343
RESURFACE PROSHESIS
K
78
1135
INGROWN TOENAIL APPLIANCE, OR
K
78
1112
CAST WEDGE, YANCEY
K
77
0856
PROSTHESIS, TRAPEZIUM & TRAPEZIUM TRIAL
K
77
0501
KNEE CUFF FOR EXPRESSING FLUID
K
77
0124
PRE-ROLLED IMPERVIOUS STOCKINETTE
K
77
0079
KESSELL TOTAL SHOULDER
K
76
1222
BENZOIN ISOBUTYL ETHER
K
76
1092
INGUINAL COMPRESSIVE DEVICE (ICD)
Subpart B—Diagnostic Devices
Subpart D—Prosthetic Devices
Subpart E—Neurological Surgical Devices
Subpart E—Surgical Devices
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
OR
/
OR-misc
/
no-product-code
/
K854621
View Source
ISOSTATION KNEE MACHINE (K-100)
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K854621
510(k) Type
Traditional
Applicant
ISOTECHNOLOGIES, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
3/7/1986
Days to Decision
109 days