QHG
Defect Measurement Tool
2
Product Code
NQO
Prosthesis, Spinous Process Spacer/Plate
3
Product Code
HTM
Stimulator, Osteogenesis, Electric, Battery-Operated, Invasive
3
Product Code
HWF
Prosthesis, Ligament
3
Product Code
LML
Ligaments And Tendons, Synthetic
3
Product Code
LMN
Ceramics, Calcium Triphosphate/Hydroxypatite, Non-Load Bearing Uses
3
Product Code
LOE
Stimulator, Invasive Bone Growth
3
Product Code
LOF
Stimulator, Bone Growth, Non-Invasive
3
Product Code
LPF
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic, Cemented
3
Product Code
LPQ
Stimulator, Ultrasound And Muscle, For Use Other Than Applying Therapeutic Deep
3
Product Code
LWA
Prosthesis, Ligament, Ptfe
3
Product Code
LXC
Monitor, Pressure, Intracompartmental
U
Product Code
LXY
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Polymer/Metal/Polymer
3
Product Code
LZJ
Prosthesis, Toe (Metatarsophalangeal), Joint, Metal/Polymer, Semi-Constrained
U
Product Code
MBD
Prosthesis, Knee, Patello/Femorotibial, Unconstrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
3
Product Code
MBJ
Fastener, Fixation, Biodegradable, Hard Tissue
3
Product Code
MBS
Filler, Bone Void, Non-Osteoinduction
3
Product Code
MCV
Spinal Pedicle Screw, Fixation, Appliance System
3
Product Code
MDI
Prosthesis, Rib Replacement
U
Product Code
MJO
Prosthesis, Intervertebral Disc
3
Product Code
P
20
0022
Simplify® Cervical Artificial Disc
APPR
PMA Approval
P
17
0036
M6-C Artificial Cervical Disc
APPR
PMA Approval
P
12
0024
ACTIVL ARTIFICIAL DISC
APPR
PMA Approval
P
09
0029
PRESTIGE LP CERVICAL DISC
APPR
PMA Approval
P
11
0009
MOBI-C CERVICAL DISC PROSTHESIS (TWO-LEVEL INDICATION)
APPR
PMA Approval
P
11
0002
MOBI-C CERVICAL DISC PROSTHESIS (ONE-LEVEL INDICATION)
APPR
PMA Approval
P
10
0012
NUVASIVE PCM CERVICAL DISC SYSTEM
APWD
PMA Approval
P
10
0003
SECURE-C ARTIFICIAL CERVICAL DISC
APPR
PMA Approval
P
06
0023
BRYAN CERVICAL DISC PROSTHESIS
APPR
PMA Approval
P
07
0001
PRODISC TM-C TOTAL DISC REPLACEMENT
APPR
PMA Approval
Show All 13 Submissions
MJT
Prosthesis, Shoulder, Humeral (Bipolar Hemi-Shoulder) Metal/Polymer, Cemented Or Uncemented
3
Product Code
MOZ
Acid, Hyaluronic, Intraarticular
3
Product Code
MPK
Semi-Constrained Metal/Polymer Finger Joint Prosthesis
F
Product Code
MPW
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction
3
Product Code
MQO
Prosthetic Disc Nucleus Device
N
Product Code
MRA
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic/Metal, Cemented Or Uncemented
3
Product Code
MRW
System, Facet Screw Spinal Device
U
Product Code
NBN
Generator, Shock-Wave, For Pain Relief
3
Product Code
NCO
Implant, Cartilage, For Articular Cartilage Repair
3
Product Code
NEG
Finger Semi-Constrained Pyrolytic Carbon Uncemented Prosthesis
3
Product Code
NEK
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold With Metal Prosthesis, Osteoinduction
3
Product Code
NJL
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Metal/Polymer, Mobile Bearing
3
Product Code
NOX
Filler, Bone Void, Synthetic Peptide
3
Product Code
NRA
Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing
3
Product Code
NTG
Prosthesis, Ankle, Uncemented, Non-Constrained
3
Product Code
NVR
Intervertebral Fusion Device With Bone Graft, Solid-Sphere, Lumbar
U
Product Code
NXT
Prosthesis, Hip, Semi-Constrained, Metal/Metal, Resurfacing
3
Product Code
OJZ
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction - Hde
F
Product Code
OKD
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction - Hde, Long Bone Nonunion
F
Product Code
OME
Extracorporeal Shock Wave Treatment
3
Product Code
OMX
High Demand, Revision, Semi-Constrained, Pyrolytic Carbon, Uncemented Finger Prosthesis
F
Product Code
OVO
Prosthesis, Hip, Semi-Constrained, Ceramic-On-Metal Articulation
3
Product Code
OYR
Filler, Bone Void, Recombinant Platelet-Derived Growth Factor
N
Product Code
PBU
Bone Void Filler, Syringe
N
Product Code
PFM
Hemibridge System
N
Product Code
PGM
Growing Rod System
U
Product Code
PGN
Growing Rod System- Magnetic Actuation
U
Product Code
PIX
Elbow Joint Metal/Polymer, Constrained, Porous Coated, Uncemented Prosthesis
N
Product Code
PJY
Osseoanchored Prostheses For The Rehabilitation Of Transfemoral Amputees
3
Product Code
PNW
Prosthesis, Metatarsophalangeal Joint Cartilage Replacement Implant
3
Product Code
PWG
Spinal Fixation System
N
Product Code
QCG
Filler, Bone Void, Calcium Compound, Lower Extremity Use, Use On Bone Marrow Lesions
N
Product Code
QES
Reherniation Reduction Device
3
Product Code
QGP
Posterior Ratcheting Rod System
N
Product Code
QHP
Vertebral Body Tethering System
N
Product Code
QNN
Talus Spacer
F
Product Code
QRR
Filler, Bone Void, Calcium Compound Containing Gentamicin
2
Product Code
QJD
Absorbable Metallic Bone Fixation Fastener
2
Product Code
QKW
Shoulder Joint Humeral (Hemi-Shoulder) Ceramic Head/Metallic Stem Cemented Or Uncemented Prosthesis
2
Product Code
QVV
Medial Knee Implanted Shock Absorber
2
Product Code
QWL
Intraoperative Surgical Angle Measurement Tool
2
Product Code
QRU
Implant, Resorbable, For Articular Osteochondral Repair
3
Product Code
QWK
Prosthesis, Posterior Spinal Elements
3
Product Code
QYQ
Prosthesis, Total Talus Replacement With Soft Tissue Attachment Sites, Metal
F
Product Code
QZO
Wearable Vibration Device For Orthopedic Use
2
Product Code
QZY
Spinal Fusion Device With Quaternary Ammonium Compound Coating
2
Product Code
QZZ
Limb And Joint Salvage Device With Coating For Bacteria Reduction
2
Product Code
QVL
Absorbable Gel For Intraoperative Use In Spine Surgery
2
Product Code
SFA
Prosthesis, Finger, Semi-Constrained, Metal/Polymer
3
Product Code
Submissions with No Product Code
Miscellaneous
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
Subpart E—Neurological Surgical Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 3 April 2026 at 11:13 pm
OR
/
OR-misc
/
MJO
/
P200022
View Source
Simplify® Cervical Artificial Disc
Page Type
PMA Approval
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
Loading...
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Miscellaneous
QHG
Defect Measurement Tool
NQO
Prosthesis, Spinous Process Spacer/Plate
HTM
Stimulator, Osteogenesis, Electric, Battery-Operated, Invasive
HWF
Prosthesis, Ligament
LML
Ligaments And Tendons, Synthetic
LMN
Ceramics, Calcium Triphosphate/Hydroxypatite, Non-Load Bearing Uses
LOE
Stimulator, Invasive Bone Growth
LOF
Stimulator, Bone Growth, Non-Invasive
LPF
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic, Cemented
LPQ
Stimulator, Ultrasound And Muscle, For Use Other Than Applying Therapeutic Deep
LWA
Prosthesis, Ligament, Ptfe
LXC
Monitor, Pressure, Intracompartmental
LXY
Prosthesis, Knee, Patello/Femorotibial, Semi-Constrained, Uncemented, Polymer/Metal/Polymer
LZJ
Prosthesis, Toe (Metatarsophalangeal), Joint, Metal/Polymer, Semi-Constrained
MBD
Prosthesis, Knee, Patello/Femorotibial, Unconstrained, Uncemented, Porous, Coated, Polymer/Metal/Polymer
MBJ
Fastener, Fixation, Biodegradable, Hard Tissue
MBS
Filler, Bone Void, Non-Osteoinduction
MCV
Spinal Pedicle Screw, Fixation, Appliance System
MDI
Prosthesis, Rib Replacement
MJO
Prosthesis, Intervertebral Disc
P
20
0022
Simplify® Cervical Artificial Disc
P
17
0036
M6-C Artificial Cervical Disc
P
12
0024
ACTIVL ARTIFICIAL DISC
P
09
0029
PRESTIGE LP CERVICAL DISC
P
11
0009
MOBI-C CERVICAL DISC PROSTHESIS (TWO-LEVEL INDICATION)
P
11
0002
MOBI-C CERVICAL DISC PROSTHESIS (ONE-LEVEL INDICATION)
P
10
0012
NUVASIVE PCM CERVICAL DISC SYSTEM
P
10
0003
SECURE-C ARTIFICIAL CERVICAL DISC
P
06
0023
BRYAN CERVICAL DISC PROSTHESIS
P
07
0001
PRODISC TM-C TOTAL DISC REPLACEMENT
Show All 13 Submissions
MJT
Prosthesis, Shoulder, Humeral (Bipolar Hemi-Shoulder) Metal/Polymer, Cemented Or Uncemented
MOZ
Acid, Hyaluronic, Intraarticular
MPK
Semi-Constrained Metal/Polymer Finger Joint Prosthesis
MPW
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction
MQO
Prosthetic Disc Nucleus Device
MRA
Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Ceramic/Metal, Cemented Or Uncemented
MRW
System, Facet Screw Spinal Device
NBN
Generator, Shock-Wave, For Pain Relief
NCO
Implant, Cartilage, For Articular Cartilage Repair
NEG
Finger Semi-Constrained Pyrolytic Carbon Uncemented Prosthesis
NEK
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold With Metal Prosthesis, Osteoinduction
NJL
Prosthesis, Knee, Patellofemorotibial, Semi-Constrained, Metal/Polymer, Mobile Bearing
NOX
Filler, Bone Void, Synthetic Peptide
NRA
Prosthesis, Knee, Femorotibial, Unicompartmental, Semi-Constrained, Metal/Polymer, Mobile Bearing
NTG
Prosthesis, Ankle, Uncemented, Non-Constrained
NVR
Intervertebral Fusion Device With Bone Graft, Solid-Sphere, Lumbar
NXT
Prosthesis, Hip, Semi-Constrained, Metal/Metal, Resurfacing
OJZ
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction - Hde
OKD
Filler, Recombinant Human Bone Morphogenetic Protein, Collagen Scaffold, Osteoinduction - Hde, Long Bone Nonunion
OME
Extracorporeal Shock Wave Treatment
OMX
High Demand, Revision, Semi-Constrained, Pyrolytic Carbon, Uncemented Finger Prosthesis
OVO
Prosthesis, Hip, Semi-Constrained, Ceramic-On-Metal Articulation
OYR
Filler, Bone Void, Recombinant Platelet-Derived Growth Factor
PBU
Bone Void Filler, Syringe
PFM
Hemibridge System
PGM
Growing Rod System
PGN
Growing Rod System- Magnetic Actuation
PIX
Elbow Joint Metal/Polymer, Constrained, Porous Coated, Uncemented Prosthesis
PJY
Osseoanchored Prostheses For The Rehabilitation Of Transfemoral Amputees
PNW
Prosthesis, Metatarsophalangeal Joint Cartilage Replacement Implant
PWG
Spinal Fixation System
QCG
Filler, Bone Void, Calcium Compound, Lower Extremity Use, Use On Bone Marrow Lesions
QES
Reherniation Reduction Device
QGP
Posterior Ratcheting Rod System
QHP
Vertebral Body Tethering System
QNN
Talus Spacer
QRR
Filler, Bone Void, Calcium Compound Containing Gentamicin
QJD
Absorbable Metallic Bone Fixation Fastener
QKW
Shoulder Joint Humeral (Hemi-Shoulder) Ceramic Head/Metallic Stem Cemented Or Uncemented Prosthesis
QVV
Medial Knee Implanted Shock Absorber
QWL
Intraoperative Surgical Angle Measurement Tool
QRU
Implant, Resorbable, For Articular Osteochondral Repair
QWK
Prosthesis, Posterior Spinal Elements
QYQ
Prosthesis, Total Talus Replacement With Soft Tissue Attachment Sites, Metal
QZO
Wearable Vibration Device For Orthopedic Use
QZY
Spinal Fusion Device With Quaternary Ammonium Compound Coating
QZZ
Limb And Joint Salvage Device With Coating For Bacteria Reduction
QVL
Absorbable Gel For Intraoperative Use In Spine Surgery
SFA
Prosthesis, Finger, Semi-Constrained, Metal/Polymer
Submissions with No Product Code
Subpart B—Diagnostic Devices
Subpart D—Prosthetic Devices
Subpart E—Neurological Surgical Devices
Subpart E—Surgical Devices
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
OR
/
OR-misc
/
MJO
/
P200022
View Source
Simplify® Cervical Artificial Disc
Page Type
PMA Approval
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.