HKY · Tonometer, Manual

Ophthalmic · 21 CFR 886.1930 · Class 2

Overview

Product CodeHKY
Device NameTonometer, Manual
Regulation21 CFR 886.1930
Device ClassClass 2
Review PanelOphthalmic
3rd-Party ReviewableYes

Identification

A tonometer and accessories is a manual device intended to measure intraocular pressure by applying a known force on the globe of the eye and measuring the amount of indentation produced (Schiotz type) or to measure intraocular tension by applanation (applying a small flat disk to the cornea). Accessories for the device may include a tonometer calibrator or a tonograph recording system. The device is intended for use in the diagnosis of glaucoma.

Classification Rationale

Class II.

Recent Cleared Devices (20 of 56)

Showing 20 most recent of 56 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K241447iCare ST500 (TA04)Icare Finland OYSep 27, 2024SESE
K233516Tono-Vera® Tonometer and Ocu-Dot® Tonometer Probes (16305, 16306, 16318)Reichert, Inc.May 1, 2024SESE
K234037CATS-L Tonometer™ PrismCats Tonometer, LLCFeb 9, 2024SESE
K232143Applanation Tonometer HT-5000Huvitz Co., Ltd.Oct 23, 2023SESE
K220852iCare IC200Icare Finland OYOct 6, 2022SESE
K211355iCare HOME2Icare Finland OYJan 25, 2022SESE
K203850CATS®-D Tonometer PrismCats Tonometer, LLCJun 14, 2021SESE
K200966Icare HOME TonometerIcare Finland OYMay 7, 2020SESE
K190316Icare ic200Icare Finland OYJan 14, 2020SESE
K191314Sunkingdom Applanation Tonometer SK-R, SK-T, SK-QChongqing Sunkingdom Medical Instrument Co., Ltd.Dec 19, 2019SESE
K182491Applanation tonometer AT-2Takagi Seiko Co., Ltd.Dec 10, 2018SESE
K180839AT 030Carl Zeiss Meditec, AGJun 7, 2018SESE
K173904CATS Tonometer PrismCats Tonometer, LLCMar 9, 2018SESE
K172728Applanation tonometer AT-1Takagi Seiko Co., Ltd.Oct 17, 2017SESE
K163343Icare HOME tonometerIcare Finland OYMar 21, 2017SESE
K153694Icare ic100Icare Finland OYApr 19, 2016SESE
K142263Applanation TonometerShanghai Mediworks Precision Instruments Co. , Ltd.Apr 15, 2016SESE
K151491Falck Medical Multifunction Tonometer, FAT1Falck Medical, Inc.Jan 15, 2016SESE
K152644KEELER DISPOSABLE TONOMATE, KEELER DISPOSABLE TONOMATE, BOX OF 100Keeler LimitedDec 31, 2015SESE
K152308Sensor Medical Single Use Tonometer PrismSensor Medical Technology, LLCOct 13, 2015SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...