FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Clinical Chemistry Test Systems
CFR Sub-Part
Subpart B—Diagnostic Devices
CFR Sub-Part
Subpart B—Obstetrical and Gynecological Diagnostic Devices
CFR Sub-Part
Subpart C—Cardiovascular Monitoring Devices
CFR Sub-Part
Subpart C—Obstetrical and Gynecological Monitoring Devices
CFR Sub-Part
Subpart D—Cardiovascular Prosthetic Devices
CFR Sub-Part
Subpart D—Obstetrical and Gynecological Prosthetic Devices
CFR Sub-Part
Subpart D—Physical Medicine Prosthetic Devices
CFR Sub-Part
Subpart D—Prosthetic Devices
CFR Sub-Part
Subpart E—Obstetrical and Gynecological Surgical Devices
CFR Sub-Part
HER
Pelvimeter, External
1
Product Code
FHG
Bell, Circumcision
2
Product Code
FHJ
Shield, Circumcision
2
Product Code
HCY
Curette, Uterine
1
Product Code
HCZ
Forceps, Surgical, Gynecological
2
Product Code
HDA
Forceps, Obstetrical
2
Product Code
HDB
Extractor, Vacuum, Fetal
2
Product Code
HDC
Tenaculum, Uterine
2
Product Code
HDD
Table, Obstetrical, Ac-Powered (And Accessories)
2
Product Code
HDE
Hook, Fibroid, Gynecological
1
Product Code
HDF
Speculum, Vaginal, Metal
1
Product Code
HDG
Speculum, Vaginal, Metal, Fiberoptic
1
Product Code
HDH
Needle, Cerclage, Gynecological
1
Product Code
HDI
Hook, Destructive, Obstetrical
2
Product Code
HDJ
Scissors, Umbilical
1
Product Code
HDK
Scissors, Episiotomy
1
Product Code
HDL
Retractor, Vaginal
1
Product Code
HDM
Packer, Uterine
1
Product Code
HDN
Dilator, Cervical, Expandable
3
Product Code
HDP
Elevator, Uterine
2
Product Code
HDQ
Dilator, Cervical, Fixed Size
1
Product Code
HDY
Dilator, Cervical, Hygroscopic-Laminaria
2
Product Code
HDZ
Knife, Cervical Cone
2
Product Code
HFB
Forceps, Biopsy, Gynecological
1
Product Code
HFG
Coagulator, Laparoscopic, Unipolar (And Accessories)
2
Product Code
HFH
Coagulator, Hysteroscopic (And Accessories)
2
Product Code
HFI
Coagulator, Culdoscopic (And Accessories)
2
Product Code
HFW
Clamp, Umbilical
2
Product Code
HFX
Clamp, Circumcision
2
Product Code
HFZ
Craniotribe
2
Product Code
HGA
Cranioclast
2
Product Code
HGC
Clamp, Uterine
1
Product Code
HGD
Applicator, Vaginal
1
Product Code
HGE
Amniotome
1
Product Code
HGI
Electrocautery, Gynecologic (And Accessories)
2
Product Code
HHF
Remover, Intrauterine Device, Contraceptive, Hook-Type
1
Product Code
HHG
Dilator, Cervical, Vibratory
3
Product Code
HHM
Sound, Uterine
1
Product Code
HHN
Cleidoclast
2
Product Code
HHO
Screw, Fibroid, Gynecological
2
Product Code
HHP
Table, Obstetrical, Manual (And Accessories)
2
Product Code
HHR
Laser, Surgical, Gynecologic
2
Product Code
HHT
Spatula, Cervical, Cytological
2
Product Code
HIB
Speculum, Vaginal, Nonmetal
2
Product Code
HIC
Speculum, Vaginal, Nonmetal, Fiberoptic
2
Product Code
HIM
Electrocautery, Endoscopic And Accessories
2
Product Code
HIN
Coagulator-Cutter, Endoscopic, Bipolar (And Accessories)
2
Product Code
KNA
Instrument, Manual, Specialized Obstetric-Gynecologic
2
Product Code
KNB
Instrument, Destructive, Fetal, Obstetric
2
Product Code
KNC
Table, Obstetric (And Accessories)
2
Product Code
KNF
Coagulator-Cutter, Endoscopic, Unipolar (And Accessories)
2
Product Code
KOH
Instrument, Manual, General Obstetric-Gynecologic
1
Product Code
LBX
Pelvimeter, Internal
2
Product Code
LKF
Cannula, Manipulator/Injector, Uterine
2
Product Code
K
25
3403
FemVue® Controlled Saline-Air Device (FSA-300)
2
Cleared 510(K)
K
25
2260
RELIEEV HSG Catheter (HSG7FA1)
2
Cleared 510(K)
K
24
2002
FemVue MINI Saline-Air Device
2
Cleared 510(K)
K
24
0364
RELIEEV Uterine Manipulator Injector (CUMI 5.0)
2
Cleared 510(K)
K
24
1693
FemChec Controlled Saline-Air Device (FCD-250)
2
Cleared 510(K)
K
22
2798
Rejoni Intrauterine Catheter
2
Cleared 510(K)
K
22
3064
ALLY II Uterine Positioning System™ (UPS)
2
Cleared 510(K)
K
22
0202
Uterine ElevatOR PRO with OccludOR Balloon
2
Cleared 510(K)
K
21
2505
DUMI ManipulatOR
2
Cleared 510(K)
K
18
1770
Intrauterine Access Balloon Catheter, Selective Salpingography Catheter
2
Cleared 510(K)
K
18
0300
Margolin HSG Cannula, Goldstein Sonohysterography Catheter
2
Cleared 510(K)
K
18
0291
Cook Silicone Balloon HSG Catheter
2
Cleared 510(K)
K
17
2846
Uterine Manipulator
2
Cleared 510(K)
K
17
1604
Rösch Thurmond Fallopian Tube Catheterization Set, Fallopian Tube Catheterization Set, and Fallopian Tube Catheterization Wire Guide with Platinum Tip
2
Cleared 510(K)
K
16
3214
Unicare System, Unicare Manipulator
2
Cleared 510(K)
K
16
0217
uVue HSG/SHG Catheter
2
Cleared 510(K)
K
15
3092
Ally Uterine Positioning System
2
Cleared 510(K)
K
15
0519
ManipulatOR PRO, ManipulatOR
2
Cleared 510(K)
K
14
2545
SonoFlow Sonohysterography and Sonohysterosalpingography Device
2
Cleared 510(K)
K
14
3415
Air Bubble Based Infuser (ABBI)
2
Cleared 510(K)
K
14
2716
VCARE
2
Cleared 510(K)
K
14
2164
MANIPULATOR; MANIPULATOR PRO
2
Cleared 510(K)
K
14
1523
ALLY UPS
2
Cleared 510(K)
K
13
1781
CLEARVIEW TOTAL
2
Cleared 510(K)
K
13
0758
KRONNER SIDE-KICK UTERINE MANIPULATOR HOLDER
2
Cleared 510(K)
K
12
2820
VIKY UP
2
Cleared 510(K)
K
12
3258
THE ADVANCE CATHETER FOR HSG AND SIS
2
Cleared 510(K)
K
10
2898
BELLOTA SONOHYSTEROGRAPHY CATHETER WITH CERVICAL CONE, BELLOTA SONOHYSTEROGRAPHY CATHETER WITHOUT CERVICAL CONE
2
Cleared 510(K)
K
11
0993
FEMCHEC PRESSURE MANAGEMET DEVICE
2
Cleared 510(K)
K
11
0288
FEMVUE SALINE-AIR DEVICE
2
Cleared 510(K)
K
09
2983
PANPAC HSG CATHETER SET
2
Cleared 510(K)
K
09
2969
H/S CATHETER SET 5 FRENCH, MODEL 61-5005F, H/S CATHETER SET 7 FRENCH, MODEL 61-5007F
2
Cleared 510(K)
K
10
0662
FEMVUE CORNUAL BALLOON CATHETER
2
Cleared 510(K)
K
09
2984
PANPAC UTERINE INECTOR, MODEL UI-4.0, UI-2.0
2
Cleared 510(K)
K
09
3556
VCARE DX
2
Cleared 510(K)
K
09
2980
PANPAC UTERINE MANIPULATOR INJECTOR, MODEL UMI 4.5
2
Cleared 510(K)
K
08
3594
EZ HSG CATHETER.FOAMSEAL CATHETER
2
Cleared 510(K)
K
08
3690
FEMVUE(TM) CATHETER SYSTEM
2
Cleared 510(K)
K
07
1405
PROBE HOLDER SYSTEM
2
Cleared 510(K)
K
07
1907
VCARE RETRACTOR/ELEVATOR
2
Cleared 510(K)
K
06
3611
SALINE/ CONTRAST MEDIA INFUSION CATHETER
2
Cleared 510(K)
K
06
1679
WALLACE ARTIFICIAL INSEMINATION CATHETER
2
Cleared 510(K)
K
04
1062
INTRAUTERINE VENOGRAM NEEDLE SET
2
Cleared 510(K)
K
04
0238
SOFTSEAL HSG CATHETER
2
Cleared 510(K)
K
04
1094
HSG CATHETER SET
2
Cleared 510(K)
K
03
2835
H/S CATHETER SET
2
Cleared 510(K)
K
02
3051
INTRAUTERINE DELIVERY SYSTEM - INJECTOR
2
Cleared 510(K)
K
02
2503
UTERINE INJECTOR
2
Cleared 510(K)
K
02
1272
SIB CATHETER, MODEL 61-7005
2
Cleared 510(K)
K
02
0954
H/S PROCEDURE TRAY (5F), H/S PROCEDURE TRAY (7F), H/S ELLIPTOSPHERE PROCEDURE TRAY & MULTIPURPOSE PROCEDURE TRAY
2
Cleared 510(K)
K
02
0292
UTERINE INJECTOR
2
Cleared 510(K)
K
02
0951
H/S CATHETER SET (5F), MODEL 61-5005; H/S CATHETER SET (7F), MODEL 61-5007
2
Cleared 510(K)
K
01
3972
H/S ELLIPTOSPHERE CATHETER SET, MODEL 61-4005
2
Cleared 510(K)
K
01
3491
HSG CATHETER SET, 5F MODEL RGS0947, HSG CATHETER SET, 7F, MODEL R65-948
2
Cleared 510(K)
K
01
3437
SF SH CATHETER, MODEL R65-945
2
Cleared 510(K)
K
01
0296
UTERINE MANIPULATOR INJECTOR CANNULA, MODEL R57-450
2
Cleared 510(K)
K
01
0056
UTERINE MANIPULATOR INJECTOR CANNULA, STERILE, MODEL R 57-450
2
Cleared 510(K)
K
00
0433
PBN HYSTERO-SALPINGOGRAPHY CATHETER SET
2
Cleared 510(K)
K
00
1115
ULTRA CATHETER SET
2
Cleared 510(K)
K
97
4357
UTERINE MANIPULATOR/INJECTOR
2
Cleared 510(K)
K
97
0492
INTRAUTERINE INSEMINATION AND SONOHYSTEROGRAPHY CATHETER
2
Cleared 510(K)
K
96
1752
H/S CATHETER SET(61-3005, 61-3007, 61-3605, 61-3607)
2
Cleared 510(K)
K
95
5446
CONMED VCARE RETRACTOR/ELEVATOR
2
Cleared 510(K)
K
95
5508
ROSCH -THURMOND FALLOPIAN TUBE CATHETERIZATION SET
2
Cleared 510(K)
K
94
6220
CONMED VCARE (VAGINAL-CERVICAL AHLUQALIA'S RETRACTOR-ELEVATOR) RETRACTOR/ELEVATOR
2
Cleared 510(K)
K
95
3034
H/S CATHETER SET(61-3005, 61-3007, 61-3605, 61-3607)
2
Cleared 510(K)
K
94
3494
HSG CATHETER SET FOR HYSTERSALPINGOGRAPHY
2
Cleared 510(K)
K
93
1167
OVAMED FALLOPIAN OSTIAL ACCESS CATHETER
2
Cleared 510(K)
K
94
3448
LUMIN
2
Cleared 510(K)
K
93
1122
OVAMED HSG CATHETER
2
Cleared 510(K)
K
93
2394
BERNSTEIN(TM) UTERINE MANIPULATOR
2
Cleared 510(K)
K
94
1458
UTERINE MANIPULATOR/INJECTOR WITH SPRING
2
Cleared 510(K)
K
94
1457
UTERINE INJECTOR WITH SPRING
2
Cleared 510(K)
K
93
5023
GODAT UTERINE MANIPULATOR INJECTOR
2
Cleared 510(K)
K
93
3981
CERVICAL CATHETER
2
Cleared 510(K)
K
93
3723
CONCEPTUS UTERINE CATHETER
2
Cleared 510(K)
K
94
0681
CLEARVIEW UTERINE MANIPULATOR
2
Cleared 510(K)
K
93
0867
AUTO SUTURE DISPOSABLE UTERINE MANIPULATOR
2
Cleared 510(K)
K
93
2115
ROWDEN UTERINE MANIPULATOR INJECTOR AND RUMI
2
Cleared 510(K)
K
93
1814
DMI UTERINE MOBILIZER/ELEVATOR/CANNULA
2
Cleared 510(K)
K
93
5434
OBSTETRIC-GYNECOLOGIC SPECIALIZED MANUAL INSTRUMENT
2
Cleared 510(K)
K
93
2432
KRONNER REINFORCING STYLETTE
2
Cleared 510(K)
K
93
0038
CANNULA: KAHN, JARCO, CORSON AND RATCHET
2
Cleared 510(K)
K
91
1887
MAJOLI UTERINE MANIPULATOR/INJECTOR
2
Cleared 510(K)
K
90
4079
BARD UTERINE MANIPULATOR
2
Cleared 510(K)
K
90
2975
TWIN BALLOON INJECTOR
2
Cleared 510(K)
K
77
2230
CANNULA, PERFUSION, FALLOPIAN TUBE
2
Cleared 510(K)
LLW
Laser, Neodymium:Yag For Gynecologic Use
2
Product Code
MDG
System, Intrafallopian Cannula
2
Product Code
MLS
Labor And Delivery Kit
2
Product Code
MLT
Pelvic Exam Kit
2
Product Code
MOV
Catheters, Salpingography
2
Product Code
MPU
Source, Chemiluminescent Light
2
Product Code
NBZ
Clamp And Cutter, Umbilical
2
Product Code
NMG
Forceps, Biopsy, Gynecological, Reprocessed
2
Product Code
OHC
Obstetrical Vacuum Delivery Kit
2
Product Code
PBQ
Fixation, Non-Absorbable Or Absorbable, For Pelvic Use
2
Product Code
OHG
Circumcision Tray
2
Product Code
PFJ
Catheter, Balloon, Dilation Of Cervical Canal Prior To Labor
2
Product Code
OHL
Pap Smear Kit
2
Product Code
OJF
Hysterectomy Kit
2
Product Code
PGK
Cannula, Injector, Uterine, Endometrial Biopsy
2
Product Code
PKN
Dilator, Cervical, Synthetic, Osmotic
2
Product Code
OKU
Emergency Obstetrical Kit
1
Product Code
OKV
Obstetrical Kit
2
Product Code
OKY
Cytology Kit
2
Product Code
OQY
Intrauterine Tamponade Balloon
2
Product Code
PMU
Containment System, Laparoscopic Power Morcellation, With Instrument Port
2
Product Code
PON
Catheter, Balloon, Dilation Of Cervical Canal
2
Product Code
PUA
Tenaculum, Uterine, Exempt
2
Product Code
PVR
D&C Tray
2
Product Code
PVX
Vaginal Examination Tray
2
Product Code
PWB
Fetal Head Elevator
2
Product Code
PWI
Instrumentation, Surgical Mesh, Urogynecologic, Transvaginal Repair Of Pelvic Organ Prolapse
2
Product Code
PWK
Instrumentation, Surgical Mesh, Urogynecologic, Transabdominal Repair Of Pelvic Organ Prolapse
2
Product Code
Subpart F—Obstetrical and Gynecological Therapeutic Devices
CFR Sub-Part
Subpart F—Therapeutic Devices
CFR Sub-Part
Subpart G—Assisted Reproduction Devices
CFR Sub-Part
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
OB
/
subpart-e—obstetrical-and-gynecological-surgical-devices
/
LKF
/
K021272
View Source
SIB CATHETER, MODEL 61-7005
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K021272
510(k) Type
Special
Applicant
Ackrad Laboratories
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
5/21/2002
Days to Decision
29 days
Submission Type
Summary
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Miscellaneous
Subpart B—Clinical Chemistry Test Systems
Subpart B—Diagnostic Devices
Subpart B—Obstetrical and Gynecological Diagnostic Devices
Subpart C—Cardiovascular Monitoring Devices
Subpart C—Obstetrical and Gynecological Monitoring Devices
Subpart D—Cardiovascular Prosthetic Devices
Subpart D—Obstetrical and Gynecological Prosthetic Devices
Subpart D—Physical Medicine Prosthetic Devices
Subpart D—Prosthetic Devices
Subpart E—Obstetrical and Gynecological Surgical Devices
HER
Pelvimeter, External
FHG
Bell, Circumcision
FHJ
Shield, Circumcision
HCY
Curette, Uterine
HCZ
Forceps, Surgical, Gynecological
HDA
Forceps, Obstetrical
HDB
Extractor, Vacuum, Fetal
HDC
Tenaculum, Uterine
HDD
Table, Obstetrical, Ac-Powered (And Accessories)
HDE
Hook, Fibroid, Gynecological
HDF
Speculum, Vaginal, Metal
HDG
Speculum, Vaginal, Metal, Fiberoptic
HDH
Needle, Cerclage, Gynecological
HDI
Hook, Destructive, Obstetrical
HDJ
Scissors, Umbilical
HDK
Scissors, Episiotomy
HDL
Retractor, Vaginal
HDM
Packer, Uterine
HDN
Dilator, Cervical, Expandable
HDP
Elevator, Uterine
HDQ
Dilator, Cervical, Fixed Size
HDY
Dilator, Cervical, Hygroscopic-Laminaria
HDZ
Knife, Cervical Cone
HFB
Forceps, Biopsy, Gynecological
HFG
Coagulator, Laparoscopic, Unipolar (And Accessories)
HFH
Coagulator, Hysteroscopic (And Accessories)
HFI
Coagulator, Culdoscopic (And Accessories)
HFW
Clamp, Umbilical
HFX
Clamp, Circumcision
HFZ
Craniotribe
HGA
Cranioclast
HGC
Clamp, Uterine
HGD
Applicator, Vaginal
HGE
Amniotome
HGI
Electrocautery, Gynecologic (And Accessories)
HHF
Remover, Intrauterine Device, Contraceptive, Hook-Type
HHG
Dilator, Cervical, Vibratory
HHM
Sound, Uterine
HHN
Cleidoclast
HHO
Screw, Fibroid, Gynecological
HHP
Table, Obstetrical, Manual (And Accessories)
HHR
Laser, Surgical, Gynecologic
HHT
Spatula, Cervical, Cytological
HIB
Speculum, Vaginal, Nonmetal
HIC
Speculum, Vaginal, Nonmetal, Fiberoptic
HIM
Electrocautery, Endoscopic And Accessories
HIN
Coagulator-Cutter, Endoscopic, Bipolar (And Accessories)
KNA
Instrument, Manual, Specialized Obstetric-Gynecologic
KNB
Instrument, Destructive, Fetal, Obstetric
KNC
Table, Obstetric (And Accessories)
KNF
Coagulator-Cutter, Endoscopic, Unipolar (And Accessories)
KOH
Instrument, Manual, General Obstetric-Gynecologic
LBX
Pelvimeter, Internal
LKF
Cannula, Manipulator/Injector, Uterine
K
25
3403
FemVue® Controlled Saline-Air Device (FSA-300)
K
25
2260
RELIEEV HSG Catheter (HSG7FA1)
K
24
2002
FemVue MINI Saline-Air Device
K
24
0364
RELIEEV Uterine Manipulator Injector (CUMI 5.0)
K
24
1693
FemChec Controlled Saline-Air Device (FCD-250)
K
22
2798
Rejoni Intrauterine Catheter
K
22
3064
ALLY II Uterine Positioning System™ (UPS)
K
22
0202
Uterine ElevatOR PRO with OccludOR Balloon
K
21
2505
DUMI ManipulatOR
K
18
1770
Intrauterine Access Balloon Catheter, Selective Salpingography Catheter
K
18
0300
Margolin HSG Cannula, Goldstein Sonohysterography Catheter
K
18
0291
Cook Silicone Balloon HSG Catheter
K
17
2846
Uterine Manipulator
K
17
1604
Rösch Thurmond Fallopian Tube Catheterization Set, Fallopian Tube Catheterization Set, and Fallopian Tube Catheterization Wire Guide with Platinum Tip
K
16
3214
Unicare System, Unicare Manipulator
K
16
0217
uVue HSG/SHG Catheter
K
15
3092
Ally Uterine Positioning System
K
15
0519
ManipulatOR PRO, ManipulatOR
K
14
2545
SonoFlow Sonohysterography and Sonohysterosalpingography Device
K
14
3415
Air Bubble Based Infuser (ABBI)
K
14
2716
VCARE
K
14
2164
MANIPULATOR; MANIPULATOR PRO
K
14
1523
ALLY UPS
K
13
1781
CLEARVIEW TOTAL
K
13
0758
KRONNER SIDE-KICK UTERINE MANIPULATOR HOLDER
K
12
2820
VIKY UP
K
12
3258
THE ADVANCE CATHETER FOR HSG AND SIS
K
10
2898
BELLOTA SONOHYSTEROGRAPHY CATHETER WITH CERVICAL CONE, BELLOTA SONOHYSTEROGRAPHY CATHETER WITHOUT CERVICAL CONE
K
11
0993
FEMCHEC PRESSURE MANAGEMET DEVICE
K
11
0288
FEMVUE SALINE-AIR DEVICE
K
09
2983
PANPAC HSG CATHETER SET
K
09
2969
H/S CATHETER SET 5 FRENCH, MODEL 61-5005F, H/S CATHETER SET 7 FRENCH, MODEL 61-5007F
K
10
0662
FEMVUE CORNUAL BALLOON CATHETER
K
09
2984
PANPAC UTERINE INECTOR, MODEL UI-4.0, UI-2.0
K
09
3556
VCARE DX
K
09
2980
PANPAC UTERINE MANIPULATOR INJECTOR, MODEL UMI 4.5
K
08
3594
EZ HSG CATHETER.FOAMSEAL CATHETER
K
08
3690
FEMVUE(TM) CATHETER SYSTEM
K
07
1405
PROBE HOLDER SYSTEM
K
07
1907
VCARE RETRACTOR/ELEVATOR
K
06
3611
SALINE/ CONTRAST MEDIA INFUSION CATHETER
K
06
1679
WALLACE ARTIFICIAL INSEMINATION CATHETER
K
04
1062
INTRAUTERINE VENOGRAM NEEDLE SET
K
04
0238
SOFTSEAL HSG CATHETER
K
04
1094
HSG CATHETER SET
K
03
2835
H/S CATHETER SET
K
02
3051
INTRAUTERINE DELIVERY SYSTEM - INJECTOR
K
02
2503
UTERINE INJECTOR
K
02
1272
SIB CATHETER, MODEL 61-7005
K
02
0954
H/S PROCEDURE TRAY (5F), H/S PROCEDURE TRAY (7F), H/S ELLIPTOSPHERE PROCEDURE TRAY & MULTIPURPOSE PROCEDURE TRAY
K
02
0292
UTERINE INJECTOR
K
02
0951
H/S CATHETER SET (5F), MODEL 61-5005; H/S CATHETER SET (7F), MODEL 61-5007
K
01
3972
H/S ELLIPTOSPHERE CATHETER SET, MODEL 61-4005
K
01
3491
HSG CATHETER SET, 5F MODEL RGS0947, HSG CATHETER SET, 7F, MODEL R65-948
K
01
3437
SF SH CATHETER, MODEL R65-945
K
01
0296
UTERINE MANIPULATOR INJECTOR CANNULA, MODEL R57-450
K
01
0056
UTERINE MANIPULATOR INJECTOR CANNULA, STERILE, MODEL R 57-450
K
00
0433
PBN HYSTERO-SALPINGOGRAPHY CATHETER SET
K
00
1115
ULTRA CATHETER SET
K
97
4357
UTERINE MANIPULATOR/INJECTOR
K
97
0492
INTRAUTERINE INSEMINATION AND SONOHYSTEROGRAPHY CATHETER
K
96
1752
H/S CATHETER SET(61-3005, 61-3007, 61-3605, 61-3607)
K
95
5446
CONMED VCARE RETRACTOR/ELEVATOR
K
95
5508
ROSCH -THURMOND FALLOPIAN TUBE CATHETERIZATION SET
K
94
6220
CONMED VCARE (VAGINAL-CERVICAL AHLUQALIA'S RETRACTOR-ELEVATOR) RETRACTOR/ELEVATOR
K
95
3034
H/S CATHETER SET(61-3005, 61-3007, 61-3605, 61-3607)
K
94
3494
HSG CATHETER SET FOR HYSTERSALPINGOGRAPHY
K
93
1167
OVAMED FALLOPIAN OSTIAL ACCESS CATHETER
K
94
3448
LUMIN
K
93
1122
OVAMED HSG CATHETER
K
93
2394
BERNSTEIN(TM) UTERINE MANIPULATOR
K
94
1458
UTERINE MANIPULATOR/INJECTOR WITH SPRING
K
94
1457
UTERINE INJECTOR WITH SPRING
K
93
5023
GODAT UTERINE MANIPULATOR INJECTOR
K
93
3981
CERVICAL CATHETER
K
93
3723
CONCEPTUS UTERINE CATHETER
K
94
0681
CLEARVIEW UTERINE MANIPULATOR
K
93
0867
AUTO SUTURE DISPOSABLE UTERINE MANIPULATOR
K
93
2115
ROWDEN UTERINE MANIPULATOR INJECTOR AND RUMI
K
93
1814
DMI UTERINE MOBILIZER/ELEVATOR/CANNULA
K
93
5434
OBSTETRIC-GYNECOLOGIC SPECIALIZED MANUAL INSTRUMENT
K
93
2432
KRONNER REINFORCING STYLETTE
K
93
0038
CANNULA: KAHN, JARCO, CORSON AND RATCHET
K
91
1887
MAJOLI UTERINE MANIPULATOR/INJECTOR
K
90
4079
BARD UTERINE MANIPULATOR
K
90
2975
TWIN BALLOON INJECTOR
K
77
2230
CANNULA, PERFUSION, FALLOPIAN TUBE
LLW
Laser, Neodymium:Yag For Gynecologic Use
MDG
System, Intrafallopian Cannula
MLS
Labor And Delivery Kit
MLT
Pelvic Exam Kit
MOV
Catheters, Salpingography
MPU
Source, Chemiluminescent Light
NBZ
Clamp And Cutter, Umbilical
NMG
Forceps, Biopsy, Gynecological, Reprocessed
OHC
Obstetrical Vacuum Delivery Kit
PBQ
Fixation, Non-Absorbable Or Absorbable, For Pelvic Use
OHG
Circumcision Tray
PFJ
Catheter, Balloon, Dilation Of Cervical Canal Prior To Labor
OHL
Pap Smear Kit
OJF
Hysterectomy Kit
PGK
Cannula, Injector, Uterine, Endometrial Biopsy
PKN
Dilator, Cervical, Synthetic, Osmotic
OKU
Emergency Obstetrical Kit
OKV
Obstetrical Kit
OKY
Cytology Kit
OQY
Intrauterine Tamponade Balloon
PMU
Containment System, Laparoscopic Power Morcellation, With Instrument Port
PON
Catheter, Balloon, Dilation Of Cervical Canal
PUA
Tenaculum, Uterine, Exempt
PVR
D&C Tray
PVX
Vaginal Examination Tray
PWB
Fetal Head Elevator
PWI
Instrumentation, Surgical Mesh, Urogynecologic, Transvaginal Repair Of Pelvic Organ Prolapse
PWK
Instrumentation, Surgical Mesh, Urogynecologic, Transabdominal Repair Of Pelvic Organ Prolapse
Subpart F—Obstetrical and Gynecological Therapeutic Devices
Subpart F—Therapeutic Devices
Subpart G—Assisted Reproduction Devices
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
OB
/
subpart-e—obstetrical-and-gynecological-surgical-devices
/
LKF
/
K021272
View Source
SIB CATHETER, MODEL 61-7005
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K021272
510(k) Type
Special
Applicant
Ackrad Laboratories
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
5/21/2002
Days to Decision
29 days
Submission Type
Summary