HFW · Clamp, Umbilical

Obstetrics/Gynecology · 21 CFR 884.4530 · Class 2

Overview

Product CodeHFW
Device NameClamp, Umbilical
Regulation21 CFR 884.4530
Device ClassClass 2
Review PanelObstetrics/Gynecology

Identification

An obstetric-gynecologic specialized manual instrument is one of a group of devices used during obstetric-gynecologic procedures to perform manipulative diagnostic and surgical functions (e.g., dilating, grasping, measuring, and scraping), where structural integrity is the chief criterion of device performance. This type of device consists of the following:(1) An amniotome is an instrument used to rupture the fetal membranes. (2) A circumcision clamp is an instrument used to compress the foreskin of the penis during circumcision of a male infant. (3) An umbilical clamp is an instrument used to compress the umbilical cord. (4) A uterine curette is an instrument used to scrape and remove material from the uterus. (5) A fixed-size cervical dilator is any of a series of bougies of various sizes used to dilate the cervical os by stretching the cervix. (6) A uterine elevator is an instrument inserted into the uterus used to lift and manipulate the uterus. (7) A gynecological surgical forceps is an instrument with two blades and handles used to pull, grasp, or compress during gynecological examination. (8) A cervical cone knife is a cutting instrument used to excise and remove tissue from the cervix. (9) A gynecological cerclage needle is a looplike instrument used to suture the cervix. (10) A hook-type contraceptive intrauterine device (IUD) remover is an instrument used to remove an IUD from the uterus. (11) A gynecological fibroid screw is an instrument used to hold onto a fibroid. (12) A uterine sound is an instrument used to determine the depth of the uterus by inserting it into the uterine cavity. (13) A cytological cervical spatula is a blunt instrument used to scrape and remove cytological material from the surface of the cervix or vagina. (14) A gynecological biopsy forceps is an instrument with two blades and handles used for gynecological biopsy procedures. (15) A uterine tenaculum is a hooklike instrument used to seize and hold the cervix or fundus. (16) An internal pelvimeter is an instrument used within the vagina to measure the diameter and capacity of the pelvis. (17) A nonmetal vaginal speculum is a nonmetal instrument used to expose the interior of the vagina. (18) A fiberoptic nonmetal vaginal speculum is a nonmetal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.

Classification Rationale

(1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Special Controls

*Classification.* (1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Recent Cleared Devices (20 of 36)

Showing 20 most recent of 36 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K041332JOEY CLAMP OPENING TOOLMaternus, Inc.Jun 25, 2004SESE
K033846KAEN YIH UMBILICAL CORD CLAMPKaen Yih Enterprise Co., Ltd.Mar 11, 2004SESE
K020718SECURLINE UMBILICAL CORD CLAMP #3505 STERILE #3515 NON-STERILEPrecision Dynamics Corp.Jun 3, 2002SESE
K021055BUSSE UMBILICAL CORD CLAMP CUTTERBusse Hospital Disposables, Inc.Apr 29, 2002SESE
K012917DYNAREX UMBILICAL CORD LAMP, MODELS 6833 AND 6833-BDynarex Corp.Nov 28, 2001SESE
K011621KOALA CLAMP, KOALA CLAMP AND CUTTERMaternus, Inc.Aug 10, 2001SESE
K010695KOALA CLAMPMaternus, Inc.May 3, 2001SESE
K010835POSI-GRIP UMBILICAL CORD CLAMP, STERILE, MODEL 384, POSI-GRIP UMBILICAL CORD CLAMP, NON-STERILE, MODEL 385Busse Hospital Disposables, Inc.Apr 30, 2001SESE
K000227UMBICUTPollak (Intl.), Ltd.Apr 27, 2000SESE
K994367UMBILICAL CORD CLAMPMedical Sales Co.Mar 17, 2000SESE
K994263SECURLINE UMBILICAL CORD CLAMP CLIPPER #3540Precision Dynamics Corp.Jan 24, 2000SESE
K990737'ECURLINE UMBILICAL CORD CLAMP #3500Precision Dynamics Corp.Apr 6, 1999SESE
K983204HARWILL MEDICAL U-KLIP UMBILICAL CLAMPHarwill Medical (Pty) , Ltd.Feb 26, 1999SESE
K974227HOSPITAL'S CLAMPGpsDec 12, 1997SESE
K963223EZ-CIRCPhyllis Adams, Rn, Npc, MsnApr 23, 1997SESE
K963889QFC UMBILICAL CLAMPQfc IndustriesApr 18, 1997SESE
K963428UMBILICAL CLAMP AND CUTTERR.O.S.T. Medical Development, Inc.Apr 1, 1997SESE
K945841BIRTH THEFT INFANT IDENTIFICATION AND PROTECTION UMBILICAL CORD CLAMPW G M Corp.May 30, 1995SESE
K951140KORDKLAMP UMBILICAL CORD CLAMP APPLICATORBalagan Medical, Inc.May 25, 1995SESE
K933763SAVE-T-BREATH AMBILICAL CORD CLAMPSave-T-Breath Distributors C.C.Aug 29, 1994SESE

Top Applicants

Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...