Last synced on 3 April 2026 at 11:13 pm

Antiserum, Blastomyces Dermatitidis, Other

Page Type
Product Code
Regulation Medical Specialty
Microbiology
Review Panel
Microbiology
Submission Type
510(K) Exempt
Device Classification
Class 2
Regulation Number
866.3060
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 866.3060 <em>Blastomyces dermatitidis</em> serological reagents

§ 866.3060 Blastomyces dermatitidis serological reagents.

(a) Identification. Blastomyces dermatitidis serological reagents are devices that consist of antigens and antisera used in serological tests to identify antibodies to Blastomyces determatitidis in serum. The identification aids in the diagnosis of blastomycosis caused by the fungus Blastomyces dermatitidis. Blastomycosis is a chronic granulomatous (tumor-like) disease, which may be limited to the skin or lung or may be widely disseminated in the body resulting in lesions of the bones, liver, spleen, and kidneys.

(b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 866.9.

[47 FR 50823, Nov. 9, 1982, as amended at 63 FR 59226, Nov. 3, 1998]

Antiserum, Blastomyces Dermatitidis, Other

Page Type
Product Code
Regulation Medical Specialty
Microbiology
Review Panel
Microbiology
Submission Type
510(K) Exempt
Device Classification
Class 2
Regulation Number
866.3060
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 866.3060 <em>Blastomyces dermatitidis</em> serological reagents

§ 866.3060 Blastomyces dermatitidis serological reagents.

(a) Identification. Blastomyces dermatitidis serological reagents are devices that consist of antigens and antisera used in serological tests to identify antibodies to Blastomyces determatitidis in serum. The identification aids in the diagnosis of blastomycosis caused by the fungus Blastomyces dermatitidis. Blastomycosis is a chronic granulomatous (tumor-like) disease, which may be limited to the skin or lung or may be widely disseminated in the body resulting in lesions of the bones, liver, spleen, and kidneys.

(b) Classification. Class II (special controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 866.9.

[47 FR 50823, Nov. 9, 1982, as amended at 63 FR 59226, Nov. 3, 1998]