PLUM A+ INFUSION SYSTEM WITH HOSPIRA MEDNET SOFTWARE , AND PLUM A+3 INFUSION SYSTEM WITH HOSPIRA MEDNET SOFTWARE

K042081 · Hospira, Inc. · FRN · Aug 24, 2004 · General Hospital

Device Facts

Record IDK042081
Device NamePLUM A+ INFUSION SYSTEM WITH HOSPIRA MEDNET SOFTWARE , AND PLUM A+3 INFUSION SYSTEM WITH HOSPIRA MEDNET SOFTWARE
ApplicantHospira, Inc.
Product CodeFRN · General Hospital
Decision DateAug 24, 2004
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 880.5725
Device ClassClass 2
AttributesTherapeutic, 3rd-Party Reviewed

Indications for Use

The Plum A+® and Plum A+®3 Infusion System with Hospira MedNet™ Software is indicated for use in parenteral, enteral and epidural therapies and the administration of whole blood and blood products.

Device Story

Electromechanical infusion pumps (single-channel Plum A+; triple-channel Plum A+3) utilize stepper motors and inline cassettes to meter IV fluids via dedicated administration sets. Modifications add Ethernet/wireless communication via I/O modules, asset management, and server-based drug library software. User interface enhancements include dynamic font sizing, additional dose units, and clinician-controlled clinical care area (CCA) selection. Used in clinical settings by healthcare providers for standard, piggyback, or concurrent fluid delivery. Networked connectivity enables remote drug library management and asset tracking. Backwards compatible with existing pump hardware via field-installable I/O modules.

Clinical Evidence

Bench testing only. No clinical data presented.

Technological Characteristics

Electromechanical infusion pump; stepper motor actuation; inline cassette fluid metering. Connectivity: Ethernet/wireless I/O modules. Compliance: IEC 60601-1-2 2nd Edition. Software: Drug library management, asset management, server-based capability. Backwards compatible with existing Plum A+ hardware.

Indications for Use

Indicated for patients requiring parenteral, enteral, or epidural therapies, or administration of whole blood and blood products.

Regulatory Classification

Identification

An infusion pump is a device used in a health care facility to pump fluids into a patient in a controlled manner. The device may use a piston pump, a roller pump, or a peristaltic pump and may be powered electrically or mechanically. The device may also operate using a constant force to propel the fluid through a narrow tube which determines the flow rate. The device may include means to detect a fault condition, such as air in, or blockage of, the infusion line and to activate an alarm.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ AUG 2 4 2004 K\$\phi\$42081 (f. 102) ## 5 510(k) SUMMARY - 1. Submitted by: Hospira, Inc. Phone:(224) 212-4803 D-389 Bldg. H2 Fax: (224) 212-5401 275 N. Field Drive Lake Forest, IL 60045 Contact: Thomas Kozma, Ph.D. 2. Date Prepared: June 30, 2004 3. Name/Classification Infusion Pump, Class II of Device: 80 FRN - 21 CFR Parts 880.5725 4. Trade Name of Plum A+® Infusion System with Hospira MedNet™ Proposed Device: Software Plum A+ 3 Infusion System with Hospira MedNet™ Software Abbott Plum A+® Infusion Pump with HPL/RS Plug-and-5. Predicate Devices: Play Module (K031185) Abbott Plum A+3™ Multichannel Infusion Pump (K021350) ## 6. Proposed Device Description: The Plum A+® and A+®3 Infusion Systems with MedNet™ Software are electromechanical infusion pumps that use a stepper motor in conjunction with an inline cassette to meter IV fluids through dedicated intravenous administration sets. The infusion pumps and administration sets are manufactured and distributed by Hospira, Inc. The Plum A+® Infusion System is a single channel pump and Plum A+®3 Infusion System is a triple channel pump. The subject devices are modifications of the predicate infusion pumps. The modifications provide networked (Ethernet wired and wireless) communication capability through new input/output (I/O) modules as well as enhancement of the optional drug library software (on CD-ROMs) to include an asset management function and have resident server software capability. In addition, enhancements are being made to the user interface of the infusion pumps. These enhancements include adding additional dose units, eliminating trailing zeros after a decimal point, dynamic font sizing to allow longer drug and clinical care area (CCA) names and allowing the clinician to change the CCA as required. In addition, the Plug 'n Play (I/O) Module is backwards compatible so that the modifications described above can be applied to existing Plum A+® pumps. The I/O {1}------------------------------------------------ K442431 (P.2 of 2) Modules and peripheral modules are backwards compatible to existing Plum A+3™ pumps and can be inserted at a factory-authorized site. All new factory released infusion systems will be in compliance with IEC 60601-1-2 2nd Edition. Both the predicate and the proposed devices can be used for standard, piggyback, or concurrent fluid delivery using the dedicated administration sets currently marketed under K98159. No changes to these dedicated administration sets have been made or are required in order to be used with the subject devices. ## 7. Statement of Intended Use: The Plum A+® and Plum A+®3 Infusion System with Hospira MedNet™ Software is indicated for use in parenteral, enteral and epidural therapies and the administration of whole blood and blood products. These are the same indications for use as the predicate devices. ## 8. Summary of Technological Characteristics of New Device Compared to Predicate Device The subject and predicate devices are similar in design, materials of construction, components, intended use, labeling and manufacturing processes. The proposed modifications do not raise new issues of safety and/or effectiveness. Therefore, these infusion systems are substantially equivalent to the predicate infusion pumps. The claim for substantial equivalence is supported by the information provided in the 510(k) submission. {2}------------------------------------------------ Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract image of an eagle or bird-like figure with three curved lines representing its wings or body. Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 AUG 2 4 2004 Hospira, Incorporated C/O Mr. Ned E. Devine Responsible Third Party Official Entela, Incorporated 3033 Madison Avenue SE Grand Rapids, Michigan 49548 Re: K042081 Trade/Device Name: Plum A+® Infusion System with Hospira MedNet™ Software and Plum A+6'3 Infusion System with Hospira MedNet™ Software Regulation Number: 880.5725 Regulation Name: Infusion Pump Regulatory Class: II Product Code: FRN Dated: August 12, 2004 Received: August 16, 2004 Dear Mr. Devine: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device merodice comments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general approvisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting (1 writ) it har be found in the Code of Federal Regulations. Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Ecderal Register. {3}------------------------------------------------ Page 2 - Mr. Devine Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements mean that I DA nas made a decemmaries and regulations administered by other Federal agencies. of the Act of ally I ederal states and reguirements, including, but not limited to: registration 1 ou inust comply with an are labeling (21 CFR Part 801); good manufacturing practice allu listing (21 CF R Part 067), abouting systems (QS) regulation (21 CFR Part 820); and if requirements as set form in the qualifical control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) ITIS letter whilanow yourse of substantial equivalence of your device of your device to a premarket notification. - 11 vevice results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), 11 you desire specific at 100 Tompliance at (301) 594-4618. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the may obtain of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html Sincerely yours, Chiu Lin, Ph.D. Chiu Lin, Ph.D. Director Division of Anesthesiology, General Hospital, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ 510(k) Number (if known) Plum A+® Infusion System with Hospira MedNet™ Software Device Name: Plum A+®3 Infusion System with Hospira MedNet™ Software Indications for Use: Plum A+® and Plum A+ 3 Infusion Systems with Hospira MedNet™ Software . Tam A . administration of whole blood and blood products. Prescription Use × (Part 21 CFR 801 Subpart D) . . AND/OR Over-The-Counter Use (Part 21 CFR 807 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) inta Lilian (Division Sign-Off) (Division of Anesthesiology, General Hospital, Infection Control, Dental Devices 510(k) Number: _______________________________________________________________________________________________________________________________________________________________ Page 1 of 1
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...