FRC · Indicator, Biological Sterilization Process

General Hospital · 21 CFR 880.2800 · Class 2

Overview

Product CodeFRC
Device NameIndicator, Biological Sterilization Process
Regulation21 CFR 880.2800
Device ClassClass 2
Review PanelGeneral Hospital
3rd-Party ReviewableYes

Identification

Biological sterilization process indicator: A device intended for use by a health care provider to accompany products being sterilized through a sterilization procedure and to monitor adequacy of sterilization. The device consists of a known number of microorganisms, of known resistance to the mode of sterilization, in or on a carrier and enclosed in a protective package. Subsequent growth or failure of the microorganisms to grow under suitable conditions indicates the adequacy of sterilization. Physical/chemical sterilization process indicator: A device intended for use by a health care provider to accompany products being sterilized through a sterilization procedure and to monitor one or more parameters of the sterilization process. The adequacy of the sterilization conditions as measured by these parameters is indicated by a visible change in the device.

Classification Rationale

Class II (performance standards).

Recent Cleared Devices (20 of 206)

Showing 20 most recent of 206 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K260766Celerity 5 HP Biological Indicator (LCB052)STERIS CorporationApr 8, 2026SESE
K252680Celerity™ 20 HP Biological IndicatorSTERIS CorporationSep 24, 2025SESE
K251122Terragene® Bionova® BT20 Biological IndicatorTerrageneAug 4, 2025SESE
K251452Celerity 5 HP Biological Indicator (LCB052); Celerity 5 HP Challenge Pack (LCB059); Celerity 20 HP Biological Indicator (LCB044); Celerity 20 HP Challenge Pack (LCB045)SterisJun 6, 2025SESE
K250061Celerity IncubatorSTERIS CorporationFeb 6, 2025SESE
K250044Celerity 5 HP Biological Indicator (LCB052); Celerity 5 HP Challenge Pack (LCB059); Celerity 20 HP Biological Indicator (LCB044); Celerity 20 HP Challenge Pack (LCB045)STERIS CorporationFeb 6, 2025SESE
K2435013M™ Attest™ Super Rapid Steam Extended Cycle Clear Challenge Pack 1492PCDE; 3M™ Attest™ Auto-reader 490; 3M™ Attest™ Auto-reader 490H; 3M™ Attest™ Mini Auto-reader 490M3M CompanyJan 28, 2025SESE
K242453Terragene® Bionova® Photon Process Challenge Device with unique-point integrator (PCD225-2);Terragene® Bionova® Photon Process Challenge Device with moving-front integrator (PCD225-C)Terragene S.A.Dec 12, 2024SESE
K2425383M™ Attest™ Super Rapid Readout Biological Indicator 1493; 3M™ Attest™ Super Rapid Steam Gravity Clear Challenge Pack 1493PCDG; 3M™ Attest™ Auto-reader 490; 3M™ Attest™ Auto-reader 490H; 3M™ Attest™ Mini Auto-reader 490M3M CompanyNov 25, 2024SESE
K2419593M™ Attest™ Super Rapid Steam Clear Challenge Pack (1492PCD); 3M™ Attest™ Auto-reader (490); 3M™ Attest™ Auto-reader (490H); 3M™ Attest™ Mini Auto-reader (490M)3M CompanyOct 18, 2024SESE
K231383Terragene® Bionova® Self-Contained Biological Indicator (BT95), Terragene® Bionova® Self-Contained Biological Indicator (BT96), Terragene® Chemdye® Chemical Process Indicator (CD42), Terragene® Cintape® Chemical Process Indicator Tape (CT40)Terragene S.A.Sep 18, 2024SESE
K2417103M™ Attest™ Super Rapid Readout Biological Indicator 1492V; 3M™ Attest™ Auto-reader 490; 3M™ Attest™ Auto-reader 490H; 3M™ Attest™ Mini Auto-reader 490M3M CompanySep 12, 2024SESE
K2415423M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge Pack 1295PCD (1295PCD)3M CompanyJun 27, 2024SESE
K2407173M™ Attest™ Rapid Readout Biological Indicator 1295 and 3M™ Attest™ Vaporized Hydrogen Peroxide Tri-Metric Chemical Indicator 1348/1348E3M CompanyJun 27, 2024SESE
K2338143M™ Attest™ Super Rapid Vaporized Hydrogen Peroxide Clear Challenge Pack (1295PCD); 3M™ Attest™ Auto-reader (490); 3M™ Attest™ Auto-reader (490H); 3M™ Attest™ Mini Auto-reader (490M)3M CompanyMar 15, 2024SESE
K233681ConFirm 20 Minute IncubatorSTERIS CorporationDec 15, 2023SESE
K231490Celerity 20 HP Biological Indicator; VERIFY V24 Self-Contained Biological IndicatorSTERIS CorporationAug 7, 2023SESE
K223717Celerity 5 HP Biological Indicator; Celerity 5 HP Challenge PackSTERIS CorporationJun 15, 2023SESE
K223715Celerity IncubatorSTERIS CorporationJun 15, 2023SESE
K223023Terragene Bionava SCBI (BT96), Terragene Bionova Reader Incubators (IC10/20FRLCD, Mini-bio), Terragene Chemdye (CD42), Terragene Cintape (CT40)Plasmapp Co,., Ltd.May 9, 2023SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...