LOX · Catheters, Transluminal Coronary Angioplasty, Percutaneous

Cardiovascular · 21 CFR 870.5100 · Class 2

Overview

Product CodeLOX
Device NameCatheters, Transluminal Coronary Angioplasty, Percutaneous
Regulation21 CFR 870.5100
Device ClassClass 2
Review PanelCardiovascular

Identification

Standard PTCA Catheter: A PTCA catheter is a device that operates on the principle of hydraulic pressurization applied through an inflatable balloon attached to the distal end. A PTCA balloon catheter has a single or double lumen shaft. The catheter features a balloon of appropriate compliance for the clinical application, constructed from a polymer. The balloon is designed to uniformly expand to a specified diameter and length at a specific pressure as labeled, with well characterized rates of inflation and deflation and a defined burst pressure. The device generally features a type of radiographic marker to facilitate fluoroscopic visualization of the balloon during use. A PTCA catheter is intended for balloon dilatation of a hemodynamically significant coronary artery or bypass graft stenosis in patients evidencing coronary ischemia for the purpose of improving myocardial perfusion. A PTCA catheter may also be intended for the treatment of acute myocardial infarction; treatment of in-stent restenosis (ISR) and/or post-deployment stent expansion. Cutting/scoring PTCA Catheter: A cutting/scoring PTCA catheter is a balloon-tipped catheter with cutting/scoring elements attached, which is used in those circumstances where a high pressure balloon resistant lesion is encountered. A cutting/scoring PTCA catheter is intended for the treatment of hemodynamically significant coronary artery stenosis for the purpose of improving myocardial perfusion. A cutting/scoring PTCA catheter may also be indicated for use in complex type C lesions or for the treatment of in-stent restenosis.

Classification Rationale

Standard PTCA Catheter: Class II (special controls). The special control for this device is “Class II Special Controls Guidance Document for Certain Percutaneous Transluminal Coronary Angioplasty (PTCA) Catheters.” See § 870.1(e) for the availability of this guidance document. Cutting/scoring PTCA Catheter: Class III (premarket approval). As of May 28, 1976, an approval under section 515 of the act is required before this device may be commercially distributed. See § 870.3.

Special Controls

*Classification.* Class II (special controls). The special control for this device is “Class II Special Controls Guidance Document for Certain Percutaneous Transluminal Coronary Angioplasty (PTCA) Catheters.” See § 870.1(e) for the availability of this guidance document.(b) *Cutting/scoring PTCA Catheter* —(1)*Identification.* A cutting/scoring PTCA catheter is a balloon-tipped catheter with cutting/scoring elements attached, which is used in those circumstances where a high pressure balloon resistant lesion is encountered. A cutting/scoring PTCA catheter is intended for the treatment of hemodynamically significant coronary artery stenosis for the purpose of improving myocardial perfusion. A cutting/scoring PTCA catheter may also be indicated for use in complex type C lesions or for the treatment of in-stent restenosis.(2) *Classification.* Class III (premarket approval). As of May 28, 1976, an approval under section 515 of the act is required before this device may be commercially distributed. See § 870.3.

Recent Cleared Devices (20 of 106)

Showing 20 most recent of 106 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K252116Firefighter™ Pro PTCA Balloon CatheterShanghai MicroPort Medical (Group) Co., Ltd.Apr 7, 2026SESE
K254022FLASH Flex™ Aorto-Ostial Angioplasty SystemVerge Medical, Inc.Apr 2, 2026SESE
K252295RyureiTerumo CorporationMar 27, 2026SESE
K251970Sprinter Legend Rapid Exchange Balloon Dilatation CatheterMedtronic, IrelandJan 17, 2026SESE
K242969Pantera Pro; Pantera LEOBiotronik, Inc.Oct 25, 2024SESE
K233499Sapphire NC ULTRA Coronary Dilatation CatheterOrbusNeich Medical (Shenzhen) Co., Ltd.Aug 16, 2024SESE
K233505Sapphire ULTRA Coronary Dilatation CatheterOrbusNeich Medical (Shenzhen) Co., Ltd.Aug 15, 2024SESE
K233729Ringer perfusion balloon catheter, 2.00 x 20mm (5881); Ringer perfusion balloon catheter, 2.50 x 20mm (5882); Ringer perfusion balloon catheter, 2.50 x 30mm (5883); Ringer perfusion balloon catheter, 3.00 x 20mm (5884); Ringer perfusion balloon catheter, 3.00 x 30mm (5885); Ringer perfusion balloon catheter, 3.50 x 20mm (5886); Ringer perfusion balloon catheter, 3.50 x 30mm (5887); Ringer perfusion balloon catheter, 4.00 x 20mm (5888); Ringer perfusion balloon catheter, 4.00 x 30mm (58Vascular Solutions, LLCMay 31, 2024SESE
K223189Firefighter™ NC Pro PTCA Balloon CatheterShanghai MicroPort Medical (Group) Co., Ltd.Jul 21, 2023SESE
K230374Coronary Dilatation Balloon Catheter (VesPenetrator®), Coronary Dilatation Balloon Catheter (VesTraveler®), Coronary Dilatation Balloon Catheter (VexPander®)Dongguan TT Medical, Inc.Jun 29, 2023SESE
K230705POT PTCA Balloon Dilatation CatheterBrosmed Medical Co., Ltd.Apr 11, 2023SESE
K223022SC HONKYTONK PTCA Balloon Dilatation CatheterSino Medical Sciences Technology, Inc.Feb 15, 2023SESE
K222538NC ROCKSTAR Non-Compliant PTCA Balloon Dilatation CatheterSino Medical Sciences Technology, Inc.Dec 21, 2022SESE
K220634NC TREK NEO Coronary Dilatation CatheterAbbott VascularJun 30, 2022SESE
K220629Emerge Monorail PTCA Dilatation CatheterBoston ScientificMar 24, 2022SESE
K212393OPN NC PTCA Dilatation CatheterSis Medical AGMar 14, 2022SESE
K211349Selebrek PTCA Balloon Dilatation CatheterKossel Medtech (Suzhou) Co., Ltd.Jan 7, 2022SESE
K211807Sapphire NC 24OrbusNeich Medical (Shenzhen) Co., Ltd.Oct 14, 2021SESE
K210012Tamarin Blue PTCA RX Dilatation CatheterNatec Medical , Ltd.Jul 9, 2021SESE
K211393Selethru(TM) NC PTCA Balloon Dilatation CatheterKossel Medtech (Suzhou) Co., Ltd.Jul 2, 2021SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...