FIP · Subsystem, Water Purification

Gastroenterology, Urology · 21 CFR 876.5665 · Class 2

Overview

Product CodeFIP
Device NameSubsystem, Water Purification
Regulation21 CFR 876.5665
Device ClassClass 2
Review PanelGastroenterology, Urology
3rd-Party ReviewableYes

Identification

A water purification system for hemodialysis is a device that is intended for use with a hemodialysis system and that is intended to remove organic and inorganic substances and microbial contaminants from water used to dilute dialysate concentrate to form dialysate. This generic type of device may include a water softener, sediment filter, carbon filter, and water distillation system.

Classification Rationale

Class II (special controls). The device, when it is a water purification subsystem disinfectant, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Special Controls

*Classification.* Class II (special controls). The device, when it is a water purification subsystem disinfectant, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 117)

Showing 20 most recent of 117 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K250471AquaC UNO HFresenius Medical Care Renal Therapies Group, LLCNov 14, 2025SESE
K251851DIASAFEplusUS (F00013010)Fresenius Medical Care Renal Therapies Group, LLCOct 9, 2025SESE
K252181AquaAFresenius Medical Care North AmericaSep 9, 2025SESE
K250514UPT Series Medical RO Water Treatment SystemSpecialty Water Technologies, Inc.Mar 17, 2025SESE
K232953AquaBplus; AquaB LITEFresenius Medical Care Renal Therapies Group, LLCJun 13, 2024SESE
K223479AQUAbase nXB.Braun Medical, Inc.Aug 16, 2023SESE
K231410RenaPure Endotoxin Retentive FilterEvoqua Water Technologies, LLCJul 19, 2023SESE
K223656AmeriWater MediQA Reverse Osmosis System (MSP3HF)AmeriWater, LLCFeb 13, 2023SESE
K213507AquaAFresenius Medical Care Rental Therapies Group, LLCJul 27, 2022SESE
K211035U9000 Plus UltrafilterBaxter Healthcare CorporationOct 19, 2021SESE
K200670EON Portable RO Water Purification SystemMar Cor Purification, Inc.Apr 16, 2020SESE
K192398Millenium HXMar Cor Purification, Inc.Oct 3, 2019SESE
K182367DIASAFEplusUSFresenius Medical Care Renal Therapies Group, LLCJan 10, 2019SESE
K171099EON Portable Reverse Osmosis Water Purification SystemCantelJan 5, 2018SESE
K161304EndoPur FilterNephros, Inc.Mar 2, 2017SESE
K161844Matrix Pre-Treatment ControllerBetter Water, LLCDec 13, 2016SESE
K153329MED-TECH Water Systems Inc Exchangeable Carbon Tanks for DialysisMed-Tech Water Systems, Inc.Aug 4, 2016SESE
K143617AquaC UNO HVivonic GmbHOct 19, 2015SESE
K151637UPT Series Medical RO Water SystemSpecialty Water TechnologiesSep 23, 2015SESE
K142285AmeriWater Heatsan, 3-phase, 208v, 60hz, AmeriWater Heatsan, 3-phase, 460V, 60hz, Ameriwater Heatsan, 3-phase, 575v, 60hzAmeriwaterDec 1, 2014SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...