MEDIVISION CYSTOSCOPE
Device Facts
| Record ID | K982620 |
|---|---|
| Device Name | MEDIVISION CYSTOSCOPE |
| Applicant | Medivision Scope Service Center, Inc. |
| Product Code | FAJ · Gastroenterology, Urology |
| Decision Date | Sep 30, 1998 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.1500 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
MediVision Cystoscope is for examine of the lower urinary tract, and using additional accessories, to perform various diagnostic and therapeutic procedures. This device is marketed as a reusable device; methods for cleaning, disinfecting, and sterilization are included in latter sections of this submission under Section 5, STERILIZATION INFORMATION .
Device Story
MediVision Cystoscopes (Models MV400, MV415, MV430, MV470) are reusable endoscopic devices used for visualization of the lower urinary tract. Operated by clinicians in a clinical setting, the device allows for diagnostic and therapeutic interventions when used with compatible accessories. The device functions as a traditional cystoscope, providing optical access to the urinary tract to assist in clinical decision-making and patient treatment.
Clinical Evidence
No clinical data provided; bench testing and sterilization validation were utilized to support the submission.
Technological Characteristics
Reusable cystoscope; rigid or flexible form factor (implied by model series); intended for lower urinary tract visualization; requires manual cleaning, disinfection, and sterilization per provided protocols.
Indications for Use
Indicated for examination of the lower urinary tract and performance of diagnostic and therapeutic procedures using accessories in patients requiring cystoscopy.
Regulatory Classification
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Related Devices
- K221580 — Single-Use Flexible Cystoscope · Hunan Vathin Medical Instrument Co., Ltd. · Nov 18, 2022
- K011849 — MICRO-6-SERIES (MR-6, MR-6L) URETEROSCOPES, MRO-6 SERIES (MR-633, MR-642) URETEROSCOPES, MRO-7 SERIES (MRO-733) URETEROS · Circon Video · Dec 10, 2001
- K062725 — MAXIFLEX-SEMI FLEX SCOPE · Technology Delivery Systems, Inc. · Sep 29, 2006
- K033191 — SOHNIKS · Sohniks Endoscopy, Inc. · Mar 9, 2004
- K980592 — NTECH CYSTOSCOPES · N-Tech Endoscopy, Inc. · Apr 28, 1998