ODE · Endoscopic Suture/Plication System, Gastroesophageal Reflux Disease (Gerd)

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeODE
Device NameEndoscopic Suture/Plication System, Gastroesophageal Reflux Disease (Gerd)
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology
ImplantYes

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 20)

RecordDevice NameApplicantDecision DateDecision
K233240GERDX-SystemG-Surg GmbHJun 21, 2024SESE
K240879EsophyX Z+ Device with SerosaFuse Fasteners and AccessoriesEndogastric Solutions, Inc.Apr 26, 2024SESE
K172811EsophyX Z, EsophyX2 HDEndogastric Solutions, Inc.Oct 19, 2017SESE
K171307EsophyX2 HD Device with SerosaFuse Fasteners and Accessories, EsophyX Z Device with SerosaFuse Fasteners and AccessoriesEndogastric Solutions, Inc.Jun 22, 2017SESE
K160960EsophyX® Z Device with SerosaFuse Fasteners and AccessoriesEndogastric Solutions, Inc.May 1, 2016SESE
K151001MUSE SystemMedigus , Ltd.Jun 5, 2015SESE
K143645EsophyX® Z Fastener Delivery DeviceEndogastric Solutions, Inc.Mar 4, 2015SESE
K143634MUSE SystemMedigus , Ltd.Jan 20, 2015SESE
K142113ESOPHYX2 HDEndogastric Solutions, Inc.Sep 30, 2014SESE
K132151SRS ENDOSCOPIC STAPLING SYSTEMMedigus , Ltd.Mar 19, 2014SESE
K120299SRS ENDOSCOPIC STAPLING SYSTEMMedigus , Ltd.May 18, 2012SESE
K092400ENDOGASTRIC SOLUTIONS ESOPHYX2 SYSTEM WITH SEROSAFUSE FASTENER AND ACCESSORIES, MODEL 2.7.5Endogastric Solutions, Inc.Nov 6, 2009SESE
K072125ENDOSCOPIC PLICATION SYSTEM, EPS, EPLICATOR, PLICATOR INSTRUMENTNdo Surgical, Inc.Oct 18, 2007SESE
K071553ENDOSCOPIC PLICATION SYSTEM; EPS; PLICATORNdo Surgical, Inc.Sep 18, 2007SESE
K071651EGS SEROSAFUSE IMPLANTABLE FASTENERS, ASSOCIATED DELIVERY DEVICES AND ACCESSORIESEndogastric Solutions, Inc.Sep 14, 2007SESE
K032820MODIFICATION TO ENDOSCOPIC PLICATION SYSTEMNdo Surgical, Inc.Oct 23, 2003SESE
K031262ENDOSCOPIC PLICATION SYSTEM, MODEL 160-00760Ndo Surgical, Inc.May 23, 2003SESE
K023234ENDOSCOPIC PLICATION SYSTEMNdo Surgical, Inc.Apr 17, 2003SESE
K003956BARD ENDOCINCH SUTURING SYSTEM # 000452; 000454; 000595C.R. Bard, Inc.Jan 5, 2001SESE
K994290BARD ENDOSCOPIC SUTURING SYSTEMC.R. Bard, Inc.Mar 20, 2000SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...