NLM · Laparoscope, General & Plastic Surgery, Reprocessed

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeNLM
Device NameLaparoscope, General & Plastic Surgery, Reprocessed
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 23)

Showing 20 most recent of 23 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K201511Reprocessed Endoscopic Trocars and SleevesStryker Sustainability SolutionsJul 31, 2020SESE
K182828Medline ReNewal Reprocessed Carter-Thomason Needle Point Suture PasserSurgical Instrument Service and Savings, Inc.Apr 15, 2019SESE
K172097Reprocessed Ethicon Bladeless Trocars; Reprocessed Ethicon Universal Trocar SleevesRenovo, Inc.Oct 6, 2017SESE
K172093Reprocessed Covidien TrocarRenovo, Inc.Oct 5, 2017SESE
K160740Medline ReNewal Reprocessed ENDOPATH XCEL Trocar with OPTIVIEW TechnologySurgical Instrument Service and Savings, Inc.May 6, 2016SESE
K153258Medline ReNewal Reprocessed Versaport V2 Bladeless Optical TrocarsSurgical Instrument Service and Savings (Dba Medline RenewalApr 5, 2016SESE
K133414REPROCESSED CLOSURE SYSTEMSterilmed, Inc.Jan 22, 2014SESE
K132629REPROCESSED DILATING TIP TROCARSStryker Sustainability SolutionsDec 31, 2013SESE
K121240REPROCESSED ENDOSCOPIC TROCARSSterilmed, Inc.Jun 11, 2012SESE
K111002REPROCESSED ENDOSCOPIC TROCARSSterilmed, Inc.Jul 18, 2011SESE
K100080REPROCESSED TROCARS, MODEL B5LT AND CB5LTAscent Healthcare SolutionsMar 19, 2010SESE
K063788REPROCESSED ENDOSCOPIC TROCARS AND CANNULASAscent Healthcare SolutionsOct 15, 2007SESE
K070059REPROCESSED TROCARSAscent Healthcare SolutionsOct 2, 2007SESE
K060676NES REPROCESSED ENDOSCOPIC TROCARNortheast Scientific, Inc.Sep 7, 2007SESE
K062497REPROCESSED TROCARSAscent Healthcare SolutionsJan 31, 2007SESE
K053585VANGUARD REPROCESSED SUTURE PASSERAscent Healthcare SolutionsOct 11, 2006SESE
K052299REPROCESSED ENDOSCOPIC TROCARSterilmed, Inc.May 23, 2006SESE
K043592REPROCESSED ENDOSCOPIC TROCARSterilmed, Inc.May 23, 2005SESE
K043253VANGUARD REPROCESSED DILATING TIP AND BLUNT TROCARSVanguard Medical Concepts, Inc.Apr 8, 2005SESE
K043594VANGUARD REPROCESSED BLADED TROCAR, NON-BLADED TROCAR, TROCAR ACCESSORIESVanguard Medical Concepts, Inc.Mar 31, 2005SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...