FCX · Insufflator, Automatic Carbon-Dioxide For Endoscope

Gastroenterology, Urology · 21 CFR 876.1500 · Class 2

Overview

Product CodeFCX
Device NameInsufflator, Automatic Carbon-Dioxide For Endoscope
Regulation21 CFR 876.1500
Device ClassClass 2
Review PanelGastroenterology, Urology
3rd-Party ReviewableYes

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Classification Rationale

(1) Class II (special controls). The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9. (2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Recent Cleared Devices (20 of 24)

Showing 20 most recent of 24 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K240847MedicCO2LON (MedicCO2LON)Ide Vision, Ltd.Oct 30, 2024SESE
K230474EVA5 InsufflatorPalliare , Ltd.Mar 24, 2023SESE
K202922END 200 Endoscopic TubesetPalliare , Ltd.Jul 8, 2021SESE
K201096CO2mbiLEDKarl Storz Endoscopy America, Inc.Jun 23, 2020SESE
K190985BAROnova Insufflation System, BAROnova Accessory KitBaronova, Inc.May 14, 2019SESK
K180711FUJIFILM Endoscopic CO2 Regulator GW-100Fujifilm CorporationMay 25, 2018SESE
K162332Nexcore GI InsufflatorNexcore Technology, LLCSep 29, 2016SESE
K133976FUJIFILM ENDOSCOPIC CO2 REGULATORFujifilm Medical System U.S.A., Inc.Sep 9, 2014SESE
K132192BRACCO DIAGNOSTICS INC. PROTOCO, L TOUCH COLON INSUFFLATORBracco Diagnostic, Inc.Feb 14, 2014SESE
K123047BRACCO DIAGNOSTICS INC. CO2 ENDOSCOPIC INSUFFLATOR IN LINE TUBING SETBracco Diagnostic, Inc.Aug 6, 2013SESE
K113310ENDOGATER AVANTAGE CO2 INSUFFLATORByrne Medical, Inc.Jun 20, 2012SESE
K111648BRACCO DIAGNOSTICS, INC. CO2MPACT ENDODCOPIC INSUFFLATORBracco Diagnostic, Inc.Nov 3, 2011SESE
K090879INSUFLOW CO2IONSHIELDLexion Medical, LLCJul 23, 2009SESE
K063786ENDOSCOPIC INSUFFLATION UNIT, MODEL XECR-2Olympus Medical Systems CorporationMar 5, 2007SESE
K053008E-Z-EM ENDOSCOPIC CO2 REGULATORE-Z-Em, Inc.Dec 27, 2005SESE
K030854PROTOCO2L COLON INSUFFLATOR WITH PERFORMANCE IMPROVEMENTS, MODEL 6400E-Z-Em, Inc.Apr 16, 2003SESE
K013219PROTOCO2L INSUFFLATOR MODEL 6400E-Z-Em, Inc.Feb 19, 2002SESE
K945970INSUFFLATOR FILTER TUBING SETXylog Corp.Dec 15, 1994SESE
K930581E-Z-FLATEE-Z-Em, Inc.Jul 1, 1994SESE
K935059INSUFFLATION TUBING SET, PHX500-082Phx Technologies Corp.Dec 22, 1993SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...