BERENSTEIN COIL
Device Facts
| Record ID | K964112 |
|---|---|
| Device Name | BERENSTEIN COIL |
| Applicant | Target Therapeutics |
| Product Code | KRD · Cardiovascular |
| Decision Date | Feb 26, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 870.3300 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
Berenstein Coils are intended for the embolization of vascular malformations of the peripheral and neuro vasculature.
Device Story
Berenstein Coil; radiopaque occlusion coil; helical shape; 0.008 or 0.016 inch primary wind diameters. Delivered via injection through Target Therapeutics Infusion Catheters or Balt Magic 1.5F/1.8F catheters; requires adapter for Balt Magic catheters. Loaded in sheath-like introducer for catheter transfer. Used by physicians in clinical settings for embolization of vascular malformations; provides mechanical occlusion to reduce or stop blood flow to malformation; aids in treatment of vascular abnormalities.
Clinical Evidence
No clinical data; substantial equivalence based on identical materials, design, and performance parameters to predicate device.
Technological Characteristics
Radiopaque occlusion coil; helical geometry; 0.008 or 0.016 inch primary wind diameters; supplied with sheath-like introducer; requires adapter for specific catheter compatibility.
Indications for Use
Indicated for embolization of vascular malformations in peripheral and neuro vasculature. Patient population includes individuals requiring vascular occlusion for malformations.
Regulatory Classification
Identification
A vascular embolization device is an intravascular implant intended to control hemorrhaging due to aneurysms, certain types of tumors (e.g., nephroma, hepatoma, uterine fibroids), and arteriovenous malformations. This does not include cyanoacrylates and other embolic agents, which act by polymerization or precipitation. Embolization devices used in neurovascular applications are also not included in this classification, see § 882.5950 of this chapter.
Special Controls
*Classification.* Class II (special controls.) The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Vascular and Neurovascular Embolization Devices.” For availability of this guidance document, see § 870.1(e).
Predicate Devices
- Target Therapeutics Berenstein Coils (K961923)
Related Devices
- K961923 — BERENSTEIN COIL · Target Therapeutics · Aug 15, 1996
- K113412 — TARGET DETACHABLE COIL · Stryker Neurovascular · Dec 13, 2011
- K032590 — MICROPLEX COIL SYSTEM (MCS), HYDROCOIL EMBOLIC SYSTEM (HES) · MicroVention, Inc. · Oct 22, 2003
- K120630 — AZUR DETACHABLE 18 · MicroVention, Inc. · Mar 28, 2012
- K161429 — Target Detachable Coils · Stryker Neurovascular · Jun 22, 2016