KRD · Device, Vascular, For Promoting Embolization

Cardiovascular · 21 CFR 870.3300 · Class 2

Overview

Product CodeKRD
Device NameDevice, Vascular, For Promoting Embolization
Regulation21 CFR 870.3300
Device ClassClass 2
Review PanelCardiovascular
ImplantYes

Identification

A vascular embolization device is an intravascular implant intended to control hemorrhaging due to aneurysms, certain types of tumors (e.g., nephroma, hepatoma, uterine fibroids), and arteriovenous malformations. This does not include cyanoacrylates and other embolic agents, which act by polymerization or precipitation. Embolization devices used in neurovascular applications are also not included in this classification, see § 882.5950 of this chapter.

Classification Rationale

Class II (special controls.) The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Vascular and Neurovascular Embolization Devices.” For availability of this guidance document, see § 870.1(e).

Special Controls

*Classification.* Class II (special controls.) The special control for this device is the FDA guidance document entitled “Class II Special Controls Guidance Document: Vascular and Neurovascular Embolization Devices.” For availability of this guidance document, see § 870.1(e).

Recent Cleared Devices (20 of 134)

Showing 20 most recent of 134 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K262798LOBO Vascular Occlusion SystemOkami Medical, Inc.Oct 6, 2026SESE
K252812UniPearls® Embolic MicrospheresSuzhou Haowei Medical Technology Co., Ltd.Jul 31, 2026SESE
K261488OBSIDIO Conformable EmbolicBoston Scientific CorporationJul 24, 2026SESE
K261866Concerto Versa™ Detachable CoilMedtronic, Inc.Jun 24, 2026SESE
K260635HARBOR Occlusion DeviceNuvascular, Inc.Jun 12, 2026SESE
K260508LOBO Vascular Occlusion SystemOkami Medical, Inc.Apr 10, 2026SESE
K253511Concerto Versa™ Detachable CoilMedtronic, Inc.Jan 14, 2026SESE
K253677Tembo Embolic SystemInstylla, Inc.Dec 15, 2025SESE
K253376OBSIDIO™ Conformable Embolic (M0013972101010)Boston Scientific CorporationOct 30, 2025SESE
K250209Polyvinyl Alcohol Embolic MicrospheresCanyon Medical, Inc.Sep 23, 2025SESE
K250133HARBOR Occlusion DeviceNuvascular, Inc.Jul 9, 2025SESE
K251383Prestige Coil System (Prestige Packing Line Extension)Balt USA, LLCMay 30, 2025SESE
K250971Embosphere MicrospheresBiosphere Medical, S.A.May 16, 2025SESE
K250276Nitinol Enhanced Device (NED)Embolization, Inc.May 15, 2025SESE
K250079Ruby XL SystemPenumbra, Inc.Mar 14, 2025SESE
K242608Embozene Color-Advanced MicrospheresVarian Medical Systems, Inc.Jan 17, 2025SESE
K240873TEMBO Embolic SystemInstylla, Inc.Dec 16, 2024SESE
K242794ONCOZENE MicrospheresVarian Medical Systems, Inc.Oct 16, 2024SESE
K242507OBSIDIO™ Conformable EmbolicBoston ScientificOct 3, 2024SESE
K232934SunsphereHangzhou Yangshun Medical Technology Co.,LtdMay 30, 2024SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...