QPC · Gown, Non-Sterile, Non-Isolation, Intended To Provide Moderate Or High Barrier Protection

General, Plastic Surgery · 21 CFR 878.4040 · Class 2

Overview

Product CodeQPC
Device NameGown, Non-Sterile, Non-Isolation, Intended To Provide Moderate Or High Barrier Protection
Regulation21 CFR 878.4040
Device ClassClass 2
Review PanelGeneral, Plastic Surgery

Identification

Surgical apparel are devices that are intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. Examples include surgical caps, hoods, masks, gowns, operating room shoes and shoe covers, and isolation masks and gowns. Surgical suits and dresses, commonly known as scrub suits, are excluded.

Classification Rationale

Class II (special controls) for surgical gowns and surgical masks. A surgical N95 respirator or N95 filtering facepiece respirator is not exempt if it is intended to prevent specific diseases or infections, or it is labeled or otherwise represented as filtering surgical smoke or plumes, filtering specific amounts of viruses or bacteria, reducing the amount of and/or killing viruses, bacteria, or fungi, or affecting allergenicity, or it contains coating technologies unrelated to filtration (e.g., to reduce and or kill microorganisms). Surgical N95 respirators and N95 filtering facepiece respirators are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9, and the following conditions for exemption: (i) The user contacting components of the device must be demonstrated to be biocompatible. (ii) Analysis and nonclinical testing must: (A) Characterize flammability and be demonstrated to be appropriate for the intended environment of use; and (B) Demonstrate the ability of the device to resist penetration by fluids, such as blood and body fluids, at a velocity consistent with the intended use of the device. (iii) NIOSH approved under its regulation. (2) Class I (general controls) for surgical apparel other than surgical gowns and surgical masks. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9.

Special Controls

*Classification.* (1) Class II (special controls) for surgical gowns and surgical masks. A surgical N95 respirator or N95 filtering facepiece respirator is not exempt if it is intended to prevent specific diseases or infections, or it is labeled or otherwise represented as filtering surgical smoke or plumes, filtering specific amounts of viruses or bacteria, reducing the amount of and/or killing viruses, bacteria, or fungi, or affecting allergenicity, or it contains coating technologies unrelated to filtration (e.g., to reduce and or kill microorganisms). Surgical N95 respirators and N95 filtering facepiece respirators are exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9, and the following conditions for exemption:(i) The user contacting components of the device must be demonstrated to be biocompatible. (ii) Analysis and nonclinical testing must: (A) Characterize flammability and be demonstrated to be appropriate for the intended environment of use; and (B) Demonstrate the ability of the device to resist penetration by fluids, such as blood and body fluids, at a velocity consistent with the intended use of the device. (iii) NIOSH approved under its regulation. (2) Class I (general controls) for surgical apparel other than surgical gowns and surgical masks. The class I device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to § 878.9.

Recent Cleared Devices (13 of 13)

RecordDevice NameApplicantDecision DateDecision
K262500Stryker Steri-Shield 8 Non-Sterile Hoods and TogasStryker InstrumentsNov 4, 2026SESE
K262007PRIMED AAMI Level 3 Open Back GownsPRIMED Medical Products, Inc.Sep 11, 2026SESE
K261115VR® Personal Protective Level 4 Gown (VR Gowns)PolyConversions, Inc.Aug 11, 2026SESE
K252940VR® Personal Protective Level 3 Gown (VR Gowns)PolyConversions, Inc.Dec 16, 2025SESE
K242689AAMI Level 4 Protective; GownAzac GroupJan 13, 2025SESE
K233526Medline Open-back Level 3 Protective GownMedline Industries, LPMar 5, 2024SESE
K230384PolyWear® Personal Protective Level 3 GownPolyConversions, Inc.Aug 11, 2023SESE
K222128Protective Gown AAMI Level 4Kenpax International LimitedAug 8, 2023SESE
K212464Dukal Corporation AAMI Level 4 Open-Back Protective GownDukal CorporationMar 30, 2022SESE
K203821Donagamex Blue Performance Protective GownDong Nai Garment Corporation (Donagamex)Dec 17, 2021SESE
K210405ProTEC-USA EZDoff GownCadillac Products, Inc.Dec 15, 2021SESE
K182830Cardinal HealthTM Poly-Coated Open-Back Protective GownCardinal Health200, LLCApr 26, 2019SESE
K160337Safecare Open Back Protective Gowns and ValueCare Open Back Protective GownsBam Corporation LimitedJul 7, 2017SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...