HRX · Arthroscope

Orthopedic · 21 CFR 888.1100 · Class 2

Overview

Product CodeHRX
Device NameArthroscope
Regulation21 CFR 888.1100
Device ClassClass 2
Review PanelOrthopedic
3rd-Party ReviewableYes

Identification

An arthroscope is an electrically powered endoscope intended to make visible the interior of a joint. The arthroscope and accessories also is intended to perform surgery within a joint.

Classification Rationale

(1) Class II (performance standards).(2) Class I for the following manual arthroscopic instruments: cannulas, currettes, drill guides, forceps, gouges, graspers, knives, obturators, osteotomes, probes, punches, rasps, retractors, rongeurs, suture passers, suture knotpushers, suture punches, switching rods, and trocars. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 888.9.

Recent Cleared Devices (20 of 685)

Showing 20 most recent of 685 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K263208Vantage Lumbar Decompression KitSurGenTec, LLCOct 14, 2026SESE
K260156TruVision Single-Use 1.9mm Arthroscopy SystemNexus CMF, LLCOct 9, 2026SESE
K260203Fule Vertebroplasty Balloon CatheterBeijing Fule Science & Technology Development Co., Ltd.Aug 28, 2026SESE
K254103HOPKINS Telescopes for ArthroscopyKarl Storz SE & CO. KGAug 26, 2026SESE
K252790Digital ClarusScope System and Digital NeuroPEN SystemClarus Medical, LLCMay 26, 2026SESE
K253523Freedom DS™ Decompression SystemSpinal SimplicityApr 16, 2026SESE
K252546VantageTM Lumbar Decompression KitAllevion Medical, LLCMar 12, 2026SESE
K253217MiiS Horus Arthroscope (EJA 100); MiiS Horus Endoscope Display System -Tablet (EDS 500); MiiS Horus Endoscope Display System -Video Box (EVS 700)Medimaging Integrated Solution, Inc (Miis)Dec 23, 2025SESE
K250795PUREVUE™ FMSW.O.M. World of Medicine GmbHDec 5, 2025SESE
K252666Articulator Arthroscopic BurJoint Preservation Innovations, LLCNov 21, 2025SESE
K252458Kyphoplasty Balloon Dilatation CathetersShanghai Lange Medtech Co., Ltd.Nov 3, 2025SESE
K252020TunnelVision Endoscopic Soft Tissue Release System and the HBL Blade AssemblyHand Biomechanics Lab, Inc.Oct 15, 2025SESE
K252594UltraGuideCTR® image guided soft tissue release systemSonex HealthSep 29, 2025SESE
K243774ELID (Endoscopic Less Invasive Decompression) SystemLesspine InnovationsAug 27, 2025SESE
K241990SpineSite Endoscope SystemHydrocision, Inc.Jul 30, 2025SESE
K243602Arthrex Spine EndoscopeArthrex, Inc.May 16, 2025SESE
K242417VECTR – Video Endoscopic Carpal Tunnel Release SystemRafael Medical Devices, LLCDec 11, 2024SESE
K243020MIDASVuIntravu, Inc.Dec 2, 2024SESE
K233800Vertos mild Device Kit (MDK-0002)Vertos Medical, Inc.May 6, 2024SESE
K240535Digital ClarusScope System; Digital NeuroPEN SystemClarus Medical, LLCApr 25, 2024SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...