REFLECTION ACETABULAR REINFORCEMENT RINGS
Device Facts
| Record ID | K962541 |
|---|---|
| Device Name | REFLECTION ACETABULAR REINFORCEMENT RINGS |
| Applicant | Smith & Nephew Richards, Inc. |
| Product Code | JDJ · General, Plastic Surgery |
| Decision Date | Sep 17, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 878.3300 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Reflection Acetabular Reinforcement Ring System is indicated as follows: rheumatoid arthritis, avascular necrosis, femoral neck fractures, osteomyelitis, fracture-dislocation of the hip, and unsuccessful cup arthroplasty, endoprosthesis, femoral osteotomy, or girdlestone resection. Indications also include osteoarthritis, traumatic arthritis, slipped capita epiphysis, fused hip, and diastrophic variant. Reflection Acetabular Reinforcement Rings are intended to be used in primary and revision surgeries where the acetabulum has the deficiencies of the acetabular roof, anterior or posterior pillar, medial wall deficiency, and / or protrusion as a result of the indications listed previously. The device is for single use.
Device Story
Acetabular reinforcement ring; addresses acetabular defects; used in primary and revision hip surgeries; provides structural support for acetabular roof, pillars, or medial wall; manufactured from titanium; single-use; implanted by orthopedic surgeons in clinical/OR setting; facilitates stable fixation for acetabular components in compromised bone stock.
Clinical Evidence
No clinical data provided; safety and effectiveness based on long history of use of similar predicate devices.
Technological Characteristics
Material: Titanium. Form factor: Acetabular reinforcement ring in various sizes. Intended for single use.
Indications for Use
Indicated for patients with acetabular defects due to rheumatoid arthritis, avascular necrosis, femoral neck fractures, osteomyelitis, hip fracture-dislocation, failed prior arthroplasty/osteotomy/resection, osteoarthritis, traumatic arthritis, slipped capital epiphysis, fused hip, or diastrophic variant. Used in primary and revision surgeries involving acetabular roof, pillar, medial wall, or protrusion deficiencies.
Regulatory Classification
Identification
Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.
Predicate Devices
- Trilogy™ Acetabular System - Zimmer
- Porous Ringloc Acetabular System - Biomet
- S-ROM™ Oblong Component - Joint Medical Products Corporation
- MARS® Ringloc Component - Biomet
- Healey Flanged Component - Biomet
- Original M.E. Müller Acetabular Roof Reinforcement Ring - Protek Ltd.
- H.B. Burch- R. Schneider Reinforcement Cage
- R. Ganz Acetabular Roof Reinforcement Ring with Hook - Intermedics
- Gap Acetabular Cup - Osteonics
- Oh-Harris Protrusio Shell - Howmedica
Related Devices
- K040680 — CONTOUR HA COATED RECONSTRUCTION RING · Smith & Nephew, Inc. · Jun 14, 2004
- K060630 — REFLECTION 3-HOLE SHELL WITH ASYMMETRIC POROUS COATING · Smith & Nephew, Inc. · Jun 14, 2006
- K032348 — CONVERGE RETI-LOCK MULTI-HOLE REINFORCEMENT CUP · Centerpulse Orthopedics, Inc. · Oct 24, 2003
- K061226 — TRABECULAR METAL ACETABULAR REVISION SYSTEM CAGE · Zimmer, Inc. · Aug 2, 2006
- K113609 — NOVATION INTEGRIP ACETABULAR AUGMENTS, GROUPS 4 AND 5 · Exactech, Inc. · Jan 4, 2012