STARBRIGHT 5% SODIUM FLUORIDE VARNISH

K140349 · Nanova Biomaterials, Inc. · LBH · Sep 22, 2014 · Dental

Device Facts

Record IDK140349
Device NameSTARBRIGHT 5% SODIUM FLUORIDE VARNISH
ApplicantNanova Biomaterials, Inc.
Product CodeLBH · Dental
Decision DateSep 22, 2014
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 872.3260
Device ClassClass 2
AttributesTherapeutic

Indications for Use

StarBright™ 5% Sodium Fluoride Varnish is a fluoride containing preparation for use as a cavity varnish and for the treatment of dentin hypersensitivity.

Device Story

StarBright™ 5% Sodium Fluoride Varnish is a rosin-based dental varnish containing 5% sodium fluoride. Supplied in 0.25 mL or 0.40 mL unit-dose trays; applied to tooth surfaces by dental professionals using a disposable brush. Fluoride ions react with calcium and phosphate ions in saliva to form crystals within exposed dentin tubules; this occlusion blocks external stimuli, reducing dentin hypersensitivity. Device serves as a protective barrier for teeth. Clinical benefit includes management of hypersensitivity and cavity protection.

Clinical Evidence

No clinical data included. Substantial equivalence supported by non-clinical bench testing, including fluoride release, tubule occlusion, and biocompatibility assessments (cytotoxicity, sensitization, and irritation).

Technological Characteristics

Rosin-based 5% sodium fluoride paste formulation. Delivered in unit-dose trays (0.25 mL or 0.40 mL). Applied via disposable brush. Mechanism involves chemical reaction with salivary ions to occlude dentin tubules.

Indications for Use

Indicated for use as a cavity varnish and treatment of dentin hypersensitivity in patients requiring fluoride application.

Regulatory Classification

Identification

Cavity varnish is a device that consists of a compound intended to coat a prepared cavity of a tooth before insertion of restorative materials. The device is intended to prevent penetration of restorative materials, such as amalgam, into the dentinal tissue.

Special Controls

*Classification.* Class II (special controls). The device, when it is an external cleaning solution, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 872.9.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the words "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" arranged around the perimeter. Inside the circle is an abstract symbol that resembles a stylized human figure or a caduceus, possibly representing health and well-being. The logo is black and white. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 September 22, 2014 Nanova Biomaterials, Incorporated Mr. Andrew Ritts Senior Scientist 3806 Mojave Court Columbia, MO 65202 Re: K140349 Trade/Device Name: StarBright™ 5% Sodium Fluoride Varnish Regulation Number: 21 CFR 872.3260 Regulation Name: Cavity Varnish Regulatory Class: II Product Code: LBH Dated: August 1, 2014 Received: August 8, 2014 Dear Mr. Ritts: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. {1}------------------------------------------------ Page 2 - Mr. Ritts Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Small Manufacturers, International and Consumer Assistance at its tollfree number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm. Also, please note the regulation entitled. "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, Mary S. Runner -S Erin I. Keith, M.S. Director Division of Anesthesiology, General Hospital, Respiratory, Infection Control and Dental Devices Office of Device Evaluation Center for Devices and Radiological Health {2}------------------------------------------------ Confidential Nanova Biomaterials, Inc. StarBright™ 5% Sodium Fluoride Varnish 510(k) Notification K140349 Section 4. Indications for Use Statement (As Required by 21 CFR 807.87(e)) 510(k) Number (if known): K140349 Device Name: StarBright™ 5% Sodium Fluoride Varnish Indications For Use: StarBright™ 5% Sodium Fluoride Varnish is a fluoride containing preparation for use as a cavity varnish and for the treatment of dentin hypersensitivity. Prescription Use _____________________________________________________________________________________________________________________________________________________________ AND/OR Over-The-Counter Use (Part 21 CFR 801 Subpart D) (21 CFR 801 Subpart C) # (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) {3}------------------------------------------------ Image /page/3/Picture/0 description: The image shows the word "NANOVA" in blue font. The font is sans-serif and the letters are bold. The background is white. The logo is simple and modern. Nanova Biomaterials, Inc. StarBright™ 5% Sodium Fluoride Varnish 510(k) Notification K140349 ### Section 5. 510(k) Summary | 1) | Submitted By: | Nanova Biomaterials, Inc<br>3806 Mojave Ct.<br>Columbia, MO 65202<br>USA<br>(573)-875-6682 | |----|------------------------------------|--------------------------------------------------------------------------------------------| | | Contact Person: Andrew Ritts | Phone: (573) 823-3114 | | | Secondary Contact: Kathryn Giddens | Phone: (573) 864-1701 | | 2) | Establishment Registration No.: | NA | | 3) | Date Prepared: | July 1st, 2014 | | 4) | Device Trade Name: | StarBright™ 5% Sodium Fluoride Varnish | | 5) | Device Common Name: | Dental Varnish | | 6) | Device Classification Name: | Cavity Varnish | | 7) | Classification Panel: | Class II | | 8) | Device Class: | Dental | #### 9) Predicated Devices: StarBright™ 5% Sodium Fluoride Varnish is believed to be substantially equivalent to the following marketed products: | 510(k)<br>Number | Name of Device | Product<br>Code | Company | |------------------|----------------------|-----------------|-------------------------| | K961893 | Duraflor ® | LBH | Pharmascience, Inc. | | K092141 | 3M Vanish | LBH | 3M ESPE | | K103160 | Nupro Model 13016901 | LBH | Cao Group, Inc. | | K132109 | Enamelast | LBH | Ultradent Products, Inc | 10) Indication for Use: > StarBright™ 5% Sodium Fluoride Varnish is a fluoride containing preparation for use as a cavity varnish and for the treatment of dentin hypersensitivity. {4}------------------------------------------------ Image /page/4/Picture/0 description: The image shows the word "NANOVA" in blue font. The letters are bold and slightly blurred. The background is white. Nanova Biomaterials, Inc. StarBright™ 5% Sodium Fluoride Varnish 510(k) Notification K140349 # Section 5. 510(k) Summary - Cont. - 11) Device Description: StarBright™ 5% Sodium Fluoride Varnish is a rosin based 5% sodium fluoride varnish. This device is available in tray form unit doses of 0.25 and 0.40 mL. Fluoride ions within StarBright™ 5% Sodium Fluoride Varnish may react with calcium and phosphate ions in saliva to form crystals in exposed dentin tubules, such as in exposed root surfaces, leading to protection by blocking external stimuli thereby reducing hypersensitivity. - 12) Substantial Equivalence: The document, "Guidance on the CDRH Premarket Notification Review Program, 6/30/86 (K86-3)" was used to determine substantial equivalence: a) The applicant device has the same intended use as the 510(k) cleared predicates listed above. b) The technological characteristics of this product are believed to be substantially equivalent as those for the predicate devices and other rosin based products currently on the market. This device and its predicates are substantially equivalent in composition and material. StarBright™ 5% Sodium Fluoride Varnish is a paste formulation delivered in unit dose packaging and applied on the tooth surface with a disposable brush, similar to several 510(k) cleared products already on the market. - 13). Non-clinical performance testing: Non-clinical performance testing on StarBright™ including fluoride release and tubule occlusion support substantial equivalence to the listed predicates. Biological testing included cytotoxicity, sensitization, and irritation. The conclusions drawn from the nonclinical tests that demonstrate that the device is as safe, as effective, and performs as well as or better than the legally marketed predicate devices. - 14). Clinical performance testing: Clinical performance data was not included. {5}------------------------------------------------ Nanova Biomaterials, Inc. StarBright™ 5% Sodium Fluoride Varnish 510(k) Notification K140349 ## Section 5. 510(k) Summary - Cont. Conclusion: Nanova Biomaterials Inc. believes that StarBrightTM 5% Sodium Fluoride varnish is substantially equivalent to the currently legally marketed products. It does not introduce new indications for use, has similar technological characteristics and does not introduce new potential hazards or safety risks.
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...