- AnesthesiologyReview Panel
- CardiovascularReview Panel
- ChemistryReview Panel
- DentalReview Panel
- Ear, Nose, ThroatReview Panel
- Gastroenterology and UrologyReview Panel
- General HospitalReview Panel
- HematologyReview Panel
- ImmunologyReview Panel
- MicrobiologyReview Panel
- NeurologyReview Panel
- Obstetrical and GynecologicalReview Panel
- OphthalmicReview Panel
- OrthopedicReview Panel
- PathologyReview Panel
- Physical MedicineReview Panel
- RadiologyReview Panel
- General and Plastic SurgeryReview Panel
- ToxicologyReview Panel
- MiscellaneousMiscellaneous
- Subpart B—Clinical Chemistry Test SystemsCFR Sub-Part
- Subpart C—Clinical Laboratory InstrumentsCFR Sub-Part
- Subpart D—Clinical Toxicology Test SystemsCFR Sub-Part
- DJREnzyme Immunoassay, Methadone2Product Code
- PFTReagents For Molecular Diagnostic Test Systems1Product Code
- QKTClozapine Test System2Product Code
- DICAlcohol Dehydrogenase, Specific Reagent For Ethanol Enzyme Method2Product Code
- DIDBacillus Subtilis Microbiology Assay, Tobramycin2Product Code
- DIEHeavy Metals Control Materials1Product Code
- DIFDrug Mixture Control Materials1Product Code
- DIGCholinesterase Test Paper1Product Code
- DIHColorimetry, Cholinesterase1Product Code
- DIJLead, Delta Amino Levulinic Acid2Product Code
- DIKThin Layer Chromatography, Quinine1Product Code
- DILRadioimmunoassay, Primidone2Product Code
- DIMGas Chromatography, Salicylate2Product Code
- DINGas Chromatography, Cocaine2Product Code
- DIOEnzyme Immunoassay, Cocaine And Cocaine Metabolites2Product Code
- DIPEnzyme Immunoassay, Diphenylhydantoin2Product Code
- DIQRadioimmunoassay, Morphine (3-H), Goat Antibody Ammonium Sulfate Sep.2Product Code
- DIRFree Radical Assay, Cocaine2Product Code
- DISEnzyme Immunoassay, Barbiturate2Product Code
- DITThin Layer Chromatography, Amphetamine2Product Code
- DIWHemagglutination Inhibition, Methadone2Product Code
- DIXThin Layer Chromatography, Phenobarbital2Product Code
- DIYGas Chromatography, Ethosuximide2Product Code
- DIZDelayed Analysis, Alcohol2Product Code
- DJBRadioimmunoassay, Gentamicin (125-I), Second Antibody Sep.2Product Code
- DJCThin Layer Chromatography, Methamphetamine2Product Code
- DJDEnzyme Immunoassay, Primidone2Product Code
- DJEThin Layer Chromatography, Salicylate2Product Code
- DJFGas Chromatography, Opiates2Product Code
- DJGEnzyme Immunoassay, Opiates2Product Code
- DJHGas Chromatography, Phenobarbital2Product Code
- DJIAntiserum, Gentamicin2Product Code
- DJJFluorometry, Morphine2Product Code
- DJKDigitoxin Control Serum, Ria1Product Code
- DJLFree Radical Assay, Amphetamine2Product Code
- DJNMercury Dithiazone, Colorimetry, Barbiturate2Product Code
- DJPRadioimmunoassay, Amphetamine2Product Code
- DJQTest Reagents For Phenothiazine2Product Code
- DJXRadioimmunoassay, Ethosuximide2Product Code
- DJZDevices, Breath Trapping, Alcohol1Product Code
- DKAAntiserum, Digoxin2Product Code
- DKBCalibrators, Drug Mixture2Product Code
- DKCAlcohol Control Materials1Product Code
- DKDBacillus Subtilis, Microbiological Assay, Gentamicin2Product Code
- DKEReagents, Test, Tetrahydrocannabinol2Product Code
- DKHGas Chromatography, Diphenylhydantoin2Product Code
- DKJColorimetry, Salicylate2Product Code
- DKNRadioimmunoassay, Barbiturate2Product Code
- DKPRadioimmunoassay, Phenobarbital2Product Code
- DKQAntiserum, Digitoxin2Product Code
- DKRThin Layer Chromatography, Methadone2Product Code
- DKTFree Radical Assay, Opiates2Product Code
- DKWTest Reagents For Sulphanimide Derivatives1Product Code
- DKXThin Layer Chromatography, Barbiturate2Product Code
- DKZEnzyme Immunoassay, Amphetamine2Product Code
- DLATest Reagents For Methyl Alcohol2Product Code
- DLBRadioimmunoassay, Lsd (125-I)2Product Code
- DLDThin Layer Chromatography, Codeine2Product Code
- DLEReagents, Test, Bromides2Product Code
- DLFEnzyme Immunoassay, Ethosuximide2Product Code
- DLHGas Chromatography, Alcohol2Product Code
- DLIAcetylcholine Chloride, Specific Reagent For Pseudo Cholinesterase1Product Code
- DLJCalibrators, Drug Specific2Product Code
- DLNHemagglutination, Cocaine Metabolites (Benzoylecgnonine)2Product Code
- DLPRadioimmunoassay, Diphenylhydantoin2Product Code
- DLRHemagglutination Inhibition, Morphine2Product Code
- DLSGas Chromatograph, Alcohol (Dedicated Instruments)2Product Code
- DLTHemagglutination, Opiates2Product Code
- DLXHemagglutination Inhibition, Barbiturate2Product Code
- DLZEnzyme Immunoassay, Phenobarbital2Product Code
- DMBGas Chromatography, Methadone2Product Code
- DMFGas Liquid Chromatography, Barbiturate2Product Code
- DMIPotassium Dichromate Specific Reagent For Alcohol2Product Code
- DMJTest Reagents For Ethyl Alcohol2Product Code
- DMKLead, Protoporphyrin, Fluorometric2Product Code
- DMLNad-Nadh, Specific Reagent For Alcohol Enzyme Method2Product Code
- DMNThin Layer Chromatography, Cocaine2Product Code
- DMPDigoxin Control Serum, Ria1Product Code
- DMQGas Chromatography, Primidone2Product Code
- DMRSolution, M-Nitrophenol, Specific Reagent For Cholinesterase1Product Code
- DMTEnzymatic Method, Alcohol Dehydrogenase, Ultraviolet2Product Code
- DMXLiquid Chromatography, Salicylate2Product Code
- DMYGas Chromatography, Morphine2Product Code
- DNARadioimmunoassay, Morphine-Barbiturate (125-I), Goat Antibody2Product Code
- DNCStrip, Paper, Salicylate2Product Code
- DNDRadioimmunoassay, Digitoxin (125-I), Rabbit Antibody, Solid Phase Sep.2Product Code
- DNEAtomic Absorption, Antimony1Product Code
- DNFLiquid Chromatography, Ethosuximide2Product Code
- DNGFree Radical, Benzoylecgnonine2Product Code
- DNILiquid Chromatography, Amphetamine2Product Code
- DNJRadioimmunoassay, Digoxin (125-I), Goat Antibody, 2nd Antibody Sep.2Product Code
- DNKThin Layer Chromatography, Morphine2Product Code
- DNLRadioimmunoassay, Digoxin (125-I), Rabbit Antibody, Second Antibody Sep.2Product Code
- DNNCalibrators, Ethyl Alcohol2Product Code
- DNOHemagglutination Inhibition, Gentamicin2Product Code
- DNPThin Layer Chromatography, Ethosuximide2Product Code
- DNQRadioimmunoassay, Digoxin (3-H), Rabbit Antibody, Coated Tubes Sep.2Product Code
- DNSRadioimmunoassay, Digoxin (125-I), Rabbit Antibody, Double Label Sep.2Product Code
- DNTLiquid Chromatography, Methadone2Product Code
- DNWRadioimmunoassay, Digitoxin (3-H), Rabbit Antibody, Charcoal Sep.2Product Code
- DNXLead, Protoporphyrin Zinc Method, Fluorometric2Product Code
- DNZAtomic Absorption, Arsenic1Product Code
- DOARadioimmunoassay, Digoxin (125-I), Goat Antibody, Anion Exchange, Resin Sep.2Product Code
- DOBRadioimmunoassay, Digitoxin (3-H)2Product Code
- DODGas Chromatography, Amphetamine2Product Code
- DOERadioimmunoassay, Morphine (125-I), Goat Antibody Ammonium Sulfate Sep.2Product Code
- DOFLead, Atomic Absorption2Product Code
- DOGRadioimmunoassay, Digoxin (125-I), Rabbit Antibody, Polyethylene Glycol2Product Code
- DOHElectrometry, Cholinesterase1Product Code
- DOJPotassium Dichromate, Alcohol2Product Code
- DOKFree Radical Assay, Morphine2Product Code
- DOLFree Radical Assay, Lsd2Product Code
- DOMThin Layer Chromatography, Benzoylecgnonine2Product Code
- DONRadioimmunoassay, Digoxin (125-I), Rabbit Antibody, Solid Phase Sep.2Product Code
- DOOLiquid Chromatography, Phenobarbital2Product Code
- DORRadioimmunoassay, Digoxin (3-H), Bovine Antibody, Charcoal Sep.2Product Code
- DOSThin Layer Chromatography, Primidone2Product Code
- DOWRadioimmunoassay, Digitoxin (3-H), Rabbit Antibody, Coated Tube2Product Code
- DOXFluorometer, Lead (Dedicated Instruments)2Product Code
- DOYRadioimmunoassay, Digoxin (3-H), Goat Antibody, 2nd Antibody Sep.2Product Code
- DOZLiquid Chromatography, Diphenylhydantoin2Product Code
- DPBRadioimmunoassay, Digoxin (125-I), Rabbit Antibody, Charcoal Sep.2Product Code
- DPDRadioimmunoassay, Digoxin (3-H), Rabbit Antibody, Charcoal Sep.2Product Code
- DPEThin Layer Chromatography, Diphenylhydantoin2Product Code
- DPGRadioimmunoassay, Digitoxin (125-I), Rabbit Antibody, Coated Tube Sep.2Product Code
- DPHMercury, Atomic Absorption1Product Code
- DPIRadioimmunoassay, Digoxin (125-I), Bovine Antibody, Charcoal Sep.2Product Code
- DPJRadioimmunoassay, Amphetamine (125-I), Goat Antibody, Ammonium Sulfate Sep.2Product Code
- DPKLiquid Chromatography, Morphine2Product Code
- DPLRadioimmunoassay, Digitoxin (125-I), Bovine Antibody, Charcoal Sep.2Product Code
- DPNThin Layer Chromatography, Propoxyphene2Product Code
- DPORadioimmunoassay, Digoxin (125-I), Rabbit Antibody, Coated Tube Sep.2Product Code
- DPPFree Radical Assay, Methadone2Product Code
- DPQLiquid Chromatography, Primidone2Product Code
- JIHFlame Photometry, Lithium2Product Code
- JIIAtomic Absorption, Lithium2Product Code
- JKQGold Chloride (Colorimetric), Bromide2Product Code
- JKSSpectral Absorb. Curve, Oxyhemoglobin, Carboxyhemoglobin, Carbon-Monoxide1Product Code
- JKTGas Chromatograph, Carbon-Monoxide1Product Code
- JXMEnzyme Immunoassay, Benzodiazepine2Product Code
- JXNEnzyme Immunoassay, Propoxyphene2Product Code
- JXOEnzyme Immunoassay, Cocaine2Product Code
- KJIRadioimmunoassay, Kanamycin2Product Code
- KLBRadioimmunoassay, Tobramycin2Product Code
- KLNRadioimmunoassay, Cocaine Metabolite2Product Code
- KLOEnzymatic Radiochemical Assay, Gentamicin2Product Code
- KLPAmikacin Serum Assay2Product Code
- KLQRadioimmunoassay, Amikacin2Product Code
- KLREnzyme Immunoassay, Lidocaine2Product Code
- KLSEnzyme Immunoassay, Theophylline2Product Code
- KLTEnzyme Immunoassay, Carbamazepine2Product Code
- KXSRadioimmunoassay, Methaqualone2Product Code
- KXTEnzyme Immunoassay, Digoxin2Product Code
- KZTKit, Disc, Agar Gel Diffusion, Determine Serum Levels Of Gentamicin2Product Code
- KZWKit, Disc, Agar Gel Diffusion, Determine Serum Levels Of Kanamycin2Product Code
- KZXKit, Disc, Agar Gel Diffusion, Determine Serum Levels Of Tobramycin2Product Code
- KZYHigh Pressure Liquid Chromatography, Barbiturate2Product Code
- KZZGas Chromatography, Benzodiazepine2Product Code
- LAAHigh Pressure Liquid Chromatography, Benzodiazepine2Product Code
- LABThin Layer Chromatography, Benzodiazepine2Product Code
- LACHigh Pressure Liquid Chromatography, Cocaine And Cocaine Metabolites2Product Code
- LADGas Chromatography, Codeine2Product Code
- LAEHigh Pressure Liquid Chromatography, Codeine2Product Code
- LAFGas Chromatography, Methamphetamine2Product Code
- LAGHigh Pressure Liquid Chromatography, Methamphetamine2Product Code
- LAHHigh Pressure Liquid Chromatography, Opiates2Product Code
- LAIThin Layer Chromatography, Opiates2Product Code
- LAJGas Chromatography, Propoxyphene2Product Code
- LAKHigh Pressure Liquid Chromatography, Propoxyphene2Product Code
- LALEas Chromatography, Quinine1Product Code
- LAMHigh Pressure Liquid Chromatography, Quinine1Product Code
- LANEnzyme Immunoassay, N-Acetylprocainamide2Product Code
- LAREnzyme Immunoassay, Procainamide2Product Code
- LASDrug Specific Control Materials1Product Code
- LATRadioimmunoassay, Cannabinoid(S)2Product Code
- LAWTheophylline Control Materials1Product Code
- LAXLidocaine Control Materials1Product Code
- LAYMethotrexate Control Materials1Product Code
- LAZN-Acetylprocainamide Control Materials1Product Code
- LBAProcainamide Control Materials1Product Code
- LBZEnzyme Immunoassay, Quinidine2Product Code
- LCARadioimmunoassay, Theophylline2Product Code
- LCDEnzyme Immunoassay, Gentamicin2Product Code
- LCERadioimmunoassay, Netilmicin (I-125)2Product Code
- LCQFluorescent Immunoassay Gentamicin2Product Code
- LCRFluorescent Immunoassay, Tobramycin2Product Code
- LCSRadioimmunoassay, Digoxin (125-I)2Product Code
- LCTRadioimmunoassay, Digoxin (3-H)2Product Code
- LCWRadioimmunoassay, Digitoxin (125-I)2Product Code
- LCYU.V. Spectrometry, Theophylline2Product Code
- LCZU.V. Spectrometry, Primidone2Product Code
- LDAU.V. Spectrometry, Phenobarbital2Product Code
- LDBU.V. Spectrometry, Carbamazepine2Product Code
- LDCU.V. Spectrometry, Diphenylhydantoin2Product Code
- LDJEnzyme Immunoassay, Cannabinoids2Product Code
- LDNEnzymatic Radiochemical Assay, Amikacin2Product Code
- LDOEnzymatic Radiochemical Assay, Tobramycin2Product Code
- LDPColorimetry, Acetaminophen2Product Code
- LEGEnzyme Immunoassay, Valproic Acid2Product Code
- LEHRadioimmunoassay, Vancomycin2Product Code
- LERFluorescent Immunoassay, Theophylline2Product Code
- LESFluorescent Immunoassay, Diphenylhydantoin2Product Code
- LETFluorescent Immunoassay, Phenobarbital2Product Code
- LEWThin Layer Chromatography, Theophylline2Product Code
- LFGRadioimmunoassay, Tricyclic Antidepressant Drugs2Product Code
- LFHU.V. Spectrometry, Tricyclic Antidepressant Drugs2Product Code
- LFIHigh Pressure Liquid Chromatography, Tricyclic Antidepressant Drugs2Product Code
- LFMEnzyme Immunoassay, Digitoxin2Product Code
- LFNNephelometric Inhibition Immunoassay, Phenobarbital2Product Code
- LFONephelometric Inhibition Immunoassay, Diphenylhydantoin2Product Code
- LFTFluorescent Immunoassay, Primidone2Product Code
- LFWFluorescence Polarization Immunoassay, Tobramycin2Product Code
- LGIFluorescence Polarization Immunoassay, Carbamazepine2Product Code
- LGJFluorescence Polarization Immunoassay, Amibacin2Product Code
- LGQFluorescence Polarization Immunoassay, Phenobarbital2Product Code
- LGRFluorescence Polarization Immunoassay, Diphenylhydantoin (Total)2Product Code
- LGSFluorescence Polarization Immunoassay, Theophylline2Product Code
- LPXRadioceptor Assay, Neuroleptic Drugs2Product Code
- MKUEnzyme Immunoassay, Nicotine And Nicotine Metabolites1Product Code
- MLKThin Layer Chromatography, Tricyclic Antidepressant Drugs2Product Code
- MOJFluorescence Polarization Immunoassay, Diphenylhydantoin (Free)2Product Code
- MRSTest System, Nicotine, Cotinine, Metabolites1Product Code
- MSLSystem, Test, Topiramatee2Product Code
- NDWAssay, Porphyrin, Spectrophotometry, Lithium2Product Code
- NFTTest, Amphetamine, Over The Counter2Product Code
- NFVTest, Benzodiazepine, Over The Counter2Product Code
- NFWTest, Cannabinoid, Over The Counter2Product Code
- NFYTest, Cocaine And Cocaine Metabolites, Over The Counter2Product Code
- NGGTest, Methamphetamine, Over The Counter2Product Code
- NGITest, Morphine, Over The Counter2Product Code
- NGLTest, Opiates, Over The Counter2Product Code
- NRPSirolimus Test System2Product Code
- NTIDrug Metabolizing Enzyme Genotyping Systems2Product Code
- NWMImmunoassay, Anti-Seizure Drug2Product Code
- OAVMycophenolic Acid Test System2Product Code
- ODWCytochrome P450 2c9 (Cyp450 2c9) Drug Metabolizing Enzyme Genotyping System2Product Code
- OIWSoftware, Similarity Score Algorithm, Tissue Of Origin For Malignant Tumor Types2Product Code
- ORABreast Milk-Alcohol Test System2Product Code
- ORHLamotrigine Assay2Product Code
- ORILevetiracetam Assay2Product Code
- OTFGabapentin Assay2Product Code
- OUFEverolimus Immunoassay2Product Code
- PDYOrganophosphate Test System2Product Code
- POXEnzyme Immunoassay, Oxcarbazepine Metabolite2Product Code
- PTGTest, Methadone, Over The Counter2Product Code
- PTHTest, Barbiturate, Over The Counter2Product Code
- PUJVoriconazole Test System2Product Code
- PUXTest, Amphetamine, Employment And Insurance Testing, Exempt2Product Code
- PUYTest, Barbiturate, Employment And Insurance Testing, Exempt2Product Code
- PUZTest, Benzodiazepine, Employment And Insurance Testing, Exempt2Product Code
- PVATest, Cocaine And Cocaine Metabolite, Employment And Insurance Testing, Exempt2Product Code
- PVBTest, Codeine, Employment And Insurance Testing, Exempt2Product Code
- PVDTest, Methamphetamine, Employment And Insurance Testing, Exempt2Product Code
- PVETest, Methadone, Employment And Insurance Testing, Exempt2Product Code
- PVFTest, Methaqualone, Employment And Insurance Testing, Exempt2Product Code
- PVGTest, Morphine, Employment And Insurance Testing, Exempt2Product Code
- PVHTest, Opiates, Employment And Insurance Testing, Exempt2Product Code
- PVITest, Propoxyphene, Employment And Insurance Testing, Exempt2Product Code
- PVJTest, Cannabinoid, Employment And Insurance Testing, Exempt2Product Code
- PVKTest, Tricyclic Antidepressant Drugs, Employment And Insurance Testing, Exempt2Product Code
- QAWTest, Tricyclic Antidepressants, Over The Counter2Product Code
- QBFTest, Propoxyphene, Over The Counter2Product Code
- QBKMeprobamate Test System2Product Code
- QDRPlazomicin Test System, Immunoassay2Product Code
- Subpart F—Immunological Test SystemsCFR Sub-Part
- Subpart G—Manual Hematology DevicesCFR Sub-Part
- Subpart H—Hematology Kits and PackagesCFR Sub-Part
- Medical GeneticsReview Panel
- UnknownReview Panel
Fluorescence Polarization Immunoassay, Phenobarbital
- Page Type
- Product Code
- Regulation Medical Specialty
- Toxicology
- Review Panel
- Toxicology
- Submission Type
- 510(K)
- Device Classification
- Class 2
- Regulation Number
- 862.3660
- GMP Exempt?
- No
- Summary Malfunction Reporting
- Eligible
- Implanted Device
- No
- Life-Sustain/Support Device
- No
- Third Party Review
- Third Party Eligible
- MAUDE Alerts
- View and Sign Up For MAUDE Alerts
CFR § 862.3660 Phenobarbital test system
§ 862.3660 Phenobarbital test system.
(a) Identification. A phenobarbitol test system is a device intended to measure phenobarbital, an antiepileptic and sedative-hypnotic drug, in human specimens. Measurements obtained by this device are used in the diagnosis and treatment of phenobarbital use or overdose and in monitoring levels of phenobarbital to ensure appropriate therapy.
(b) Classification. Class II.