CARBAMAZEPINE ASSAY FOR THE TECHNICON IMMUNO 1 SYSTEM
Device Facts
| Record ID | K964068 |
|---|---|
| Device Name | CARBAMAZEPINE ASSAY FOR THE TECHNICON IMMUNO 1 SYSTEM |
| Applicant | Bayer Corp. |
| Product Code | KLT · Clinical Toxicology |
| Decision Date | Dec 13, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 862.3645 |
| Device Class | Class 2 |
Indications for Use
This in vitro method is intended to quantitatively measure carbamazepine, an anti-convulsant drug, in human serum or plasma (heparin) using Syva EMIT® 2000 Assay on a Technicon Immuno-1® system. Measurements of carbamazepine are used in the diagnosis and treatment of carbamazepine overdose and in monitoring serum levels of carbamazepine to ensure appropriate therapy.
Device Story
In vitro diagnostic assay for quantitative measurement of carbamazepine in human serum or plasma; performed on Technicon Immuno-1® system. Uses chemical reagents and calibrators to detect drug concentration; provides numerical output in μg/mL. Used in clinical laboratory settings by trained personnel. Results assist clinicians in monitoring therapeutic drug levels and managing carbamazepine overdose, ensuring appropriate patient therapy.
Clinical Evidence
Bench testing only. Performance compared against predicate using 50 clinical samples. Correlation: y = 1.07x - 0.13, r = 0.978, S_yx = 0.89 μg/mL. Precision (between-run) evaluated at multiple concentrations (2.8–16.1 μg/mL) showing CVs ranging from 4.2% to 8.7%.
Technological Characteristics
In vitro diagnostic reagent kit for automated immunoassay. Principle: quantitative measurement of carbamazepine. System: Technicon Immuno-1®. Minimum detectable concentration: 0.2 μg/mL.
Indications for Use
Indicated for patients requiring quantitative measurement of carbamazepine in human serum or plasma for diagnosis/treatment of overdose and therapeutic drug monitoring.
Regulatory Classification
Identification
A neuroleptic drugs radioceptor assay test system is a device intended to measure in serum or plasma the dopamine receptor blocking activity of neuroleptic drugs and their active metabolites. A neuroleptic drug has anti-psychotic action affecting principally psychomotor activity, is generally without hypnotic effects, and is a tranquilizer. Measurements obtained by this device are used to aid in determining whether a patient is taking the prescribed dosage level of such drugs.
Predicate Devices
- Syva EMIT® 2000 Carbamazepine Assay (Behring Diagnostics Inc.)
Reference Devices
- Roche COBAS FARA II® Instrument
Related Devices
- K042808 — ADVIA IMS CARBAMAZEPINE METHOD · Bayer Healthcare, LLC · Feb 8, 2005
- K962820 — CARBAMAZEPINE FLEX REAGENT CARTRIDGE · Dade Intl., Inc. · Sep 13, 1996
- K964442 — VALPROIC ACID ASSAY FOR THE TECHNICON IMMUNO 1 SYSTEM · Bayer Corp. · Dec 18, 1996