Wound Cleaner, Ultrasound

Page Type
Product Code
Definition
The ultrasound wound cleaner/mild debridement system is a device that delivers a cleaning fluid to the wound that is pulsed using low power ultrasound radiation. The device is intended to clean and mildly debride wounds. The ultrasound generator must deliver 1.0 mw/cm2 or less energy to the wound
Regulation Medical Specialty
General and Plastic Surgery
Review Panel
General and Plastic Surgery
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
878.4410
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Third Party Eligible

CFR § 878.4410 Low energy ultrasound wound cleaner

§ 878.4410 Low energy ultrasound wound cleaner.

(a) Identification. A low energy ultrasound wound cleaner is a device that uses ultrasound energy to vaporize a solution and generate a mist that is used for the cleaning and maintenance debridement of wounds. Low levels of ultrasound energy may be carried to the wound by the saline mist.

(b) Classification. Class II (special controls). The special control is FDA's guidance document entitled “Class II Special Controls Guidance Document: Low Energy Ultrasound Wound Cleaner.” See § 878.1(e) for the availability of this guidance document.

[70 FR 67355, Nov. 7, 2005]

Wound Cleaner, Ultrasound

Page Type
Product Code
Definition
The ultrasound wound cleaner/mild debridement system is a device that delivers a cleaning fluid to the wound that is pulsed using low power ultrasound radiation. The device is intended to clean and mildly debride wounds. The ultrasound generator must deliver 1.0 mw/cm2 or less energy to the wound
Regulation Medical Specialty
General and Plastic Surgery
Review Panel
General and Plastic Surgery
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
878.4410
GMP Exempt?
No
Summary Malfunction Reporting
Eligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Third Party Eligible

CFR § 878.4410 Low energy ultrasound wound cleaner

§ 878.4410 Low energy ultrasound wound cleaner.

(a) Identification. A low energy ultrasound wound cleaner is a device that uses ultrasound energy to vaporize a solution and generate a mist that is used for the cleaning and maintenance debridement of wounds. Low levels of ultrasound energy may be carried to the wound by the saline mist.

(b) Classification. Class II (special controls). The special control is FDA's guidance document entitled “Class II Special Controls Guidance Document: Low Energy Ultrasound Wound Cleaner.” See § 878.1(e) for the availability of this guidance document.

[70 FR 67355, Nov. 7, 2005]