MPN · Tissue Adhesive For The Topical Approximation Of Skin

General, Plastic Surgery · 21 CFR 878.4010 · Class 2

Overview

Product CodeMPN
Device NameTissue Adhesive For The Topical Approximation Of Skin
Regulation21 CFR 878.4010
Device ClassClass 2
Review PanelGeneral, Plastic Surgery

Identification

A tissue adhesive for the topical approximation of skin is a device intended for topical closure of surgical incisions, including laparoscopic incisions, and simple traumatic lacerations that have easily approximated skin edges. Tissue adhesives for the topical approximation of skin may be used in conjunction with, but not in place of, deep dermal stitches.

Classification Rationale

Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: “Tissue Adhesive for the Topical Approximation of Skin.” See § 878.1(e) of this chapter for the availability of this guidance document.

Special Controls

*Classification.* Class II (special controls). The special control for this device is FDA's “Class II Special Controls Guidance Document: “Tissue Adhesive for the Topical Approximation of Skin.” See § 878.1(e) of this chapter for the availability of this guidance document.(b) *Tissue adhesive for non-topical use* —(1)*Identification.* A tissue adhesive for non-topical use, including adhesives intended for use in the embolization of brain arteriovenous malformation or for use in ophthalmic surgery, is a device used for adhesion of internal tissues and vessels.(2) *Classification.* Class III (premarket approval). As of May 28, 1976, an approval under section 515 of the act is required before this device may be commercially distributed. See § 878.3 of this chapter.

Recent Cleared Devices (20 of 39)

Showing 20 most recent of 39 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K243990BondEase 2 Topical Skin AdhesiveOptmed, Inc.Sep 19, 2025SESE
K250950CUTIVA™ Topical Skin Adhesive (RM1700); CUTIVA™ PLUS Skin Closure System (RM1739)Okapi Medical, LLC Dba Resivant MedicalAug 4, 2025SESE
K234114CUTIVA(TM) Topical Skin Adhesive (RM-1700); CUTIVA(TM) PLUS Skin Closure System (RM-1739)Okapi Medical, LLC Dba Resivant MedicalAug 20, 2024SESE
K233458CM005 Standard (CM005); CM004 Mini (CM004)Connexicon Medical , Ltd.Jul 15, 2024SESE
K230981Meriglu Topical Skin AdhesiveM/s. Meril Endo Surgery Private Limited.Mar 16, 2024SESE
K212246Exofin Precision PenChemence Medical, Inc.Sep 9, 2021SESE
K200264Exofin High Viscosity Topical Skin AdhesiveChemence Medical, Inc.Dec 17, 2020SESE
K183570LiquiBand PlusAdvanced Medical Solutions LimitedMar 9, 2020SESE
K162352derma+flex QS High Viscosity Tissue AdhesiveChemence Medical, Inc.Dec 22, 2016SESE
K161011SURGISEAL Topical Skin Adhesive, SURGISEAL Stylus Topical Skin Adhesive, SURGISEAL Twist Topical Skin AdhesiveAdhezion Biomedical, LLCNov 8, 2016SESE
K161050ACTABOND Topical Skin AdhesiveBergen Medical Products, Inc.Oct 4, 2016SESE
K152476Exofin High Viscosity Tissue AdhesiveChemence Medical Products, Inc.Feb 9, 2016SESE
K150032GluStitch Twist Tissue AdhesiveGlustitch, Inc.Jan 14, 2016SESE
K141157BONDEASE TOPICAL SKIN ADHESIVEOptmed, Inc.Dec 22, 2015SESE
K151182LiquiBand ExceedAdvanced Medical Solutions (Plymouth), Ltd.Oct 26, 2015SESE
K152096DERMABOND Advanced Topical Skin Adhesive, High Viscosity DERMABOND Mini Topical Skin AdhesiveETHICON, Inc.Oct 22, 2015SESE
K150866SURGISEAL Topical Skin AdhesvieAdhezion Biomedical, LLCJul 17, 2015SESE
K133963SURGISEAL TWIST (TM) TOPICAL SKIN ADHESIVEAdhezion Biomedical, LLCSep 9, 2014SESE
K141215SURGISEAL TWIST TOPICAL SKIN ADHESIVEAdhezion Biomedical, LLCAug 21, 2014SESE
K140343AESCULAP HISTOACRYL, HISTOACRYL BLUE AND HISTOACRYL FLEXIBLE TOPICAL SKIN, ADHESIVE WITH APPLICATOR TIPAesculap, Inc.May 13, 2014SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.