VITRA MULTISPOT

K122251 · Quantel Medical · GEX · Jan 24, 2013 · General, Plastic Surgery

Device Facts

Record IDK122251
Device NameVITRA MULTISPOT
ApplicantQuantel Medical
Product CodeGEX · General, Plastic Surgery
Decision DateJan 24, 2013
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4810
Device ClassClass 2
AttributesTherapeutic, Pediatric

Indications for Use

The VITRA MULTISPOT Laser photocoagulator is indicated for use in the treatment of ocular pathology of anterior and posterior segments including, retinal photocoagulation and pan retinal photocoagulation of vascular and structural abnormalities of the retina and choroids including: Proliferative and nonproliferative diabetic retinopathy; Choroidal neovascularization; Branch retinal vein occlusion; Treatment of choroidal neovascularization associated with wet Age-related macular degeneration; Retinal tears and detachments; Macular edema; Retinopathy of Prematurity; Iridotomy and trabeculoplasty in angle closure glaucoma and open angle glaucoma.

Device Story

VITRA MULTISPOT is a 532nm green laser photocoagulator; uses 635-650nm red diode for aiming. Connects to scanning laser delivery system, slit lamp, or indirect ophthalmoscope. Controlled via tactile LCD screen on main housing. Delivers max 1.5W output. Used by ophthalmologists in clinical settings for retinal/choroidal photocoagulation and glaucoma procedures. Enables precise thermal treatment of ocular tissues; benefits patients by addressing vascular/structural abnormalities to prevent vision loss.

Clinical Evidence

Bench testing only. Laboratory testing verified that the device met all design specifications and performed equivalently to predicate devices.

Technological Characteristics

532nm green laser photocoagulator; 635-650nm red diode aiming beam. Max output 1.5W. Tactile LCD control interface. Compatible with scanning, slit lamp, and indirect ophthalmoscope delivery systems. Class II device.

Indications for Use

Indicated for patients with ocular pathology of anterior and posterior segments, including proliferative/nonproliferative diabetic retinopathy, choroidal neovascularization, branch retinal vein occlusion, wet age-related macular degeneration, retinal tears/detachments, macular edema, retinopathy of prematurity, and glaucoma (iridotomy/trabeculoplasty).

Regulatory Classification

Identification

(1) A carbon dioxide laser for use in general surgery and in dermatology is a laser device intended to cut, destroy, or remove tissue by light energy emitted by carbon dioxide.(2) An argon laser for use in dermatology is a laser device intended to destroy or coagulate tissue by light energy emitted by argon.

Predicate Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K 122.251 # JAN 2 4 2013 ## 510(k) Summary for the Quantel Medical VITRA MULTISPOT This 510(k) Summary is being submitted in accordance with the requirements of the SMDA 1990 and 21 CFR 807.92. #### 1. General Information Submitter: Quantel Medical 11 Rue du Bois Joli - CS 40015 63808 Cournon D'Auvergne Cedex FRANCE 33-473 745 745 33-473 745 700 (Fax) Contact Person: Maureen O'Connell O'Connell Regulatory Consultants, Inc. 5 Timber Lane North Reading, MA 01864 Telephone: 978-207-1245 Fax: 978-824-2541 Summary Preparation Date: January 23, 2013 - 2. Names Device Name: VITRA MULTISPOT Classification Name: Laser Instrument, Surgical, Powered Product Code: GEX Panel: General & Plastic Surgery ## 3. Predicate Device - Quantel Medical SUPRA SCAN™ Delivery System coupled to a SUPRA 532 . -(K100678) - Quantel Medical VITRA (K043236) - - OPTIMEDICA CORPORATION PASCAL Photocoagulator (K043486) - - OPTIMEDICA CORPORATION PASCAL Synthesis Delivery System -(K081744) {1}------------------------------------------------ #### 4. Device Description VITRA MULTISPOT is a laser photocoagulator emitting a treatment beam of green (532nm) laser radiation. The treatment beam is delivered through a delivery system and is aimed using a Red Laser diode (635-650nm). The Quantel Medical VITRA MULTISPOT Laser can be connected with the following delivery systems: - 1) Scanning Laser Delivery System adaptor - 2) Slit Lamp adaptor - 3) Indirect ophthalmoscope adaptor Output power from all these delivery systems are calibrated to deliver a maximum of 1.5 watts. The control box is a tactile LCD screen which is part of the main housing. #### 5. Indications for Use The VITRA MULTISPOT Laser is indicated for use in the treatment of ocular pathology of anterior and posterior segments including, retinal photocoagulation and pan retinal photocoagulation for vascular and structural abnormalities of the retina and choroids including: · Proliferative and nonproliferative diabetic retinopathy; ● Choroidal neovascularization; · Branch retinal vein occlusion; · Treatment of choroidal neovascularization associated with wet Age-related macular degeneration: · Retinal tears and detachments - · Macular edema - · Retinopathy of prematurity - · Iridotomy and trabeculoplasty in angle closure glaucoma and open angle glaucoma. #### 6. Substantial Equivalence The VITRA MULTISPOT Laser shares the same intended use and safety compliance, similar design features, functional features, and therefore is substantially equivalent to the predicate devices, the PASCAL Photocoagulator (K043486) and Synthesis Delivery System (K081744), VITRA (K043236) and the Quantel Medical SUPRA SCAN™ Delivery System coupled to the SUPRA 532 (K100678). In addition, a review of the predicate devices demonstrates that the VITRA MULTISPOT Laser is substantially equivalent to the predicate {2}------------------------------------------------ devices as they share equivalent specifications / characteristics and are used to perform the same indicated surgical procedures. ## 7. Performance Data Laboratory testing was conducted to validate and verify that the VITRA MULTISPOT Laser met all design specifications and was substantially equivalent to the predicate devices. {3}------------------------------------------------ #### DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/3/Picture/1 description: The image shows the logo for the Department of Health & Human Services - USA. The logo features a stylized caduceus symbol, which is a staff with two snakes entwined around it. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the caduceus symbol. The logo is black and white. Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 Quantel Medical % O'Connell Regulatory Consultants, Incorporated Ms. Maureen O'Connell Regulatory Counsultant 5 Timber Lane North Reading, Massachusetts 01864 January 24. 2013 Re: K122251 Trade/Device Name: VITRA MULTISPOT Regulation Number: 21 CFR 878.4810 Regulation Name: Laser surgical instrument for use in general and plastic surgery and in dermatology Regulatory Class: II Product Code: GEX Dated: December 12, 2012 Received: December 13, 2012 Dear Ms. O'Connell: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set {4}------------------------------------------------ # Page 2 - Ms. Maureen O'Connell forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (240) 276-0115. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, # Peter D. Rumm -S Mark N. Melkerson Acting Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ ### Indications for Use 510(k) Number (if known): ____________________________________________________________________________________________________________________________________________________ K122251 Device Name: YITRA MULTISPOT Indications for Use: The VITRA MULTISPOT Laser photocoagulator is indicated for use in the treatment of ocular pathology of anterior and posterior segments including, retinal photocoagulation and pan retinal photocoagulation of vascular and structural abnormalities of the retina and choroids including: - Proliferative and nonproliferative diabetic retinopathy; - · Choroidal neovascularization; - · Branch retinal vein occlusion; - · Treatment of choroidal neovascularization associated with wet Age-related macular degeneration; - · Retinal tears and detachments - · Macular edema - · Retinopathy of Prematurity - · Iridotomy and trabeculoplasty in angle closure glaucoma and open angle glaucoma. Prescription Use X (Part 21 CFR 801 Subpart D) AND/OR Over The Counter Use (Part 21 CFR 801 Subpart C) (PLEASE DO NOT WRITE BELOW THIS LINE – CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Page 1 of 1 Neil R Ogden 2013.01.23 14:36:51 -05'00' mkm (Division Sign-Off) tor Division of Surgical Devices 510(k) Number K122251
Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...