Aurora Evacuator

K180372 · Rebound Therapeutics · GEI · Apr 9, 2018 · General, Plastic Surgery

Device Facts

Record IDK180372
Device NameAurora Evacuator
ApplicantRebound Therapeutics
Product CodeGEI · General, Plastic Surgery
Decision DateApr 9, 2018
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 878.4400
Device ClassClass 2
AttributesTherapeutic

Intended Use

The AURORA Evacuator is a powered instrument with a handpiece intended for removal of soft tissue and fluids under direct visualization. Types of direct visualization may include laparoscopic, pelviscopic, endoscopic, percutaneous, and open. Applications include those when access to the surgical site is limited, such as Neurosurgical/Spinal and ENT/Otolaryngological.

Device Story

AURORA Evacuator is a sterile, single-use, handheld aspiration device for minimally invasive surgery. It consists of a stainless-steel suction wand with a distal aspiration window and an internal rotating whisk-shaped shaft, connected to a plastic handle containing a battery-powered motor and suction tubing. The device connects to an operating room vacuum source. The surgeon controls vacuum strength via a vent on the handle and activates the motor via a button to rotate the whisk. Soft tissue is drawn into the window by vacuum, cut by the rotating whisk, and transported through the wand and tubing to a waste receptacle. Used in OR settings by surgeons to remove soft tissue and fluids in limited-access sites. Benefits include efficient tissue removal in confined surgical fields.

Clinical Evidence

Bench testing only. Testing included biocompatibility (ISO 10993-1), electrical safety (IEC 60601-1, IEC 60529-1), electromagnetic compatibility (IEC 60601-1-2), particulate testing (USP 36 <788>), sterilization validation (ISO 11135-1), packaging/shelf-life (ISTA 2A, ASTM F1980), and product performance validation using surrogate soft tissue and fluid materials.

Technological Characteristics

Materials: stainless-steel wand, plastic handle. Energy: battery-powered DC motor. Connectivity: connects to external OR vacuum source. Dimensions: wand lengths of 7cm, 10cm, 13cm. Sterilization: validated to SAL 10^-6. Standards: ISO 10993-1, IEC 60601-1, IEC 60529-1, IEC 60601-1-2, USP 36 <788>, ISO 11135-1, ISTA 2A, ASTM F1980.

Indications for Use

Indicated for removal of soft tissue and fluids during surgical procedures (laparoscopic, endoscopic, percutaneous, open) where access is limited, including neurosurgical, spinal, and ENT/otolaryngological applications.

Regulatory Classification

Identification

An electrosurgical cutting and coagulation device and accessories is a device intended to remove tissue and control bleeding by use of high-frequency electrical current.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/0 description: The image contains the logo of the U.S. Food and Drug Administration (FDA). On the left is the Department of Health & Human Services logo. To the right of that is the FDA logo, which is a blue square with the letters "FDA" in white. To the right of the blue square is the text "U.S. FOOD & DRUG ADMINISTRATION" in blue. April 9, 2018 Rebound Therapeutics Ms. Jane Metcalf Vice President of Regulatory Affairs 13900 Alton Parkway, Suite 120 Irvine, California 92618 Re: K180372 Trade/Device Name: Aurora Evacuator Regulation Number: 21 CFR 878.4400 Regulation Name: Electrosurgical Cutting and Coagulation Device and Accessories Regulatory Class: Class II Product Code: GEI Dated: February 7, 2018 Received: February 12, 2018 Dear Ms. Metcalf: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing, practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); {1}------------------------------------------------ and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/MedicalDevices/DeviceRegulationandGuidance/) and CDRH Learn (http://www.fda.gov/Training/CDRHLearn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (http://www.fda.gov/DICE) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). > Sincerely. Jennifer R. Stevenson -S3 For Binita S. Ashar, M.D., M.B.A., F.A.C.S. Director Division of Surgical Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K180372 Device Name AURORA Evacuator Indications for Use (Describe) The AURORA Evacuator is a powered instrument with a handpiece intended for removal of soft tissue and fluids under direct visualization. Types of direct visualization may include laparoscopic, endoscopic, percutaneous, and open. Applications include those when access to the surgical site is limited, such as Neurosurgical/Spinal and ENT/ Otolaryngological. | Type of Use (Select one or both, as applicable) | | |--------------------------------------------------------------------------------------------------------------------------------|----------------------------------------------------------------------------------------------------------------| | <span style="font-size: 10pt;"> <input checked="true" type="checkbox"/> Prescription Use (Part 21 CFR 801 Subpart D) </span> | <span style="font-size: 10pt;"> <input type="checkbox"/> Over-The-Counter Use (21 CFR 801 Subpart C) </span> | #### CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. #### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ ### 1) SUBMITTER Rebound Therapeutics Corporation 13900 Alton Parkway, STE 120 Irvine, CA 92618 Contact Person: Jeffrey J. Valko, President and CEO Telephone: (949) 633-2747 Email: jvalko@reboundtx.com Contact Person: Jane Metcalf, Vice President of Regulatory Affairs Telephone: (949) 525-1493 Email: jmetcalf@reboundtx.com Date Prepared: April 3, 2018 ### 2) DEVICE Name of Device: AURORA Evacuator Common or Usual Name: Aspirator Classification Name: Electrosurgical, Cutting & Coagulation & Accessories Regulatory Class: II Product Code: GEI #### 3) PREDICATE DEVICE Primary Predicate: NICO Myriad, 11GA, K161307 Secondary Predicate: ConMed Corporation, Frazier 8Fr, Class II, 510(k) Exempt ### 4) DEVICE DESCRIPTION The AURORA Evacuator is provided sterile, for single-use only. It is a disposable, handheld, aspiration device designed to remove fluids and soft tissue during minimally invasive surgical procedures. The AURORA Evacuator consists of a stainless-steel suction wand connected to a plastic handle. The stainless-steel suction wand is configured with an aspiration window, near its distal end, for fluid and soft tissue to enter. Internal to the suction wand is a shaft with a whisk-shaped configuration at its distal end. The whisk-shaped configuration is aligned with the aspiration window. The proximal end of the shaft is connected to a battery powered motor in the handle. The interior of the plastic handle contains the battery powered motor, batteries, electrical circuitry and the suction tubing. The suction tubing connects the stainless-steel suction wand to operating room vacuum. On the exterior of the handle is a tear-dropped shaped vent for user control of vacuum strength, a green light that illuminates when power is available, and a button for user activation of the motor. {4}------------------------------------------------ The AURORA Evacuator is shipped in a non-functional state that requires removal of a pull tab from the handle to initiate power to the device. There are three (3) configurations of the AURORA Evacuator; AURORA Evacuator -13, AURORA Evacuator -10 and AURORA Evacuator -7. All configurations are fabricated from the same materials and electrical components. The only difference among the configurations is the working length of the wand component. The wand working lengths are 13cm, 10cm, and 7cm, respectively. ### 5) STATEMENT OF INTENDED USE The AURORA Evacuator is a powered instrument with a handpiece intended for removal of soft tissue and fluids under direct visualization. Types of direct visualization may include laparoscopic, pelviscopic, endoscopic, percutaneous, and open. Applications include those when access to the surgical site is limited, such as Neurosurgical/Spinal and ENT/Otolaryngological. ### 6) SUMMARY OF TESTING The following testing was conducted to demonstrate the safe and effective use of the AURORA Evacuator and its' substantial equivalence to the primary predicate. - Biocompatibility Testing per ISO 10993-1 Cytotoxicity (MEM Elution), Sensitization . (Kligman Maximization), Irritation (Intracutaneous Injection), Systemic Toxicity (Systemic Injection, Material Mediated Pyrogenicity) - Electrical Safety and Enclosure Protection per IEC 60601-1 and IEC 60529-1 ● - Emissions and Immunity per IEC 60601-1-2 - Particulate Testing per USP 36 <788>: - Sterilization per ISO 11135-1 to validate a SAL of 10-6 - Packaging and Shelf-life per ISTA 2A and ASTM F1980 - . Verification of product specifications including, materials, multiple bonds evaluations, physical characteristics, audible characteristics, rotational speeds, duration of use and operational temperatures - Validation of product performance using surrogate soft tissue materials and surrogate fluid materials # 7) SUMMARY TECHNOLOGICAL CHARACTERISTICS The AURORA Evacuator has two (2) modes of operation: one (1) for aspiration and another for cutting. For aspiration, the AURORA Evacuator connects to an external vacuum source that is present in the operating room. For cutting, the AURORA Evacuator utilizes a rotating whisk that is internal to the wand. To aspirate, the surgeon covers the suction vent on the device's handle and positions the aspiration window so that vacuum draws fluid and soft tissue through the window and into the wand. The aspirant travels through the wand, into the suction tubing and is deposited into the waste receptacle connected to the operating room vacuum-line. To cut soft tissue, the surgeon pushes the motor activation on the exterior of the handle causing the whisk to rotate. Vacuum is used to draw soft tissue through the aspiration window and into the rotating whisk. The soft tissue is cut by the rotating whisk and transported to a collection {5}------------------------------------------------ receptacle connected to the operating room vacuum-line. Soft tissue cutting can only occur inside of the wand. # 8) COMPARISON TO PREDICATE Comparing the AURORA Evacuator to the primary predicate shows that there are three main technological differences; vacuum source, energy source, and tissue cutting. The primary predicate uses an internally controlled vacuum source instead of an external vacuum source. Its energy source is from a wall outlet rather than direct current from internal batteries. Finally, the primary predicate cuts both soft tissue and solid tissue using a scissoring action. The AURORA Evacuator only cuts soft tissue and uses a rotating whisk rather than scissoring. All three of these differences have been analyzed and tested. Results show no new or different questions of safety and effectiveness. ### 9) CONCLUSION Upon reviewing the performance data provided in this submission and comparing indicated use, design, materials, principle of operation and overall technological characteristics, the AURORA Evacuator has been determined, by Rebound Therapeutics Corporation, to be substantially equivalent to the primary predicate.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...