K033671 · W. L. Gore & Associates, Inc. · OWT · Dec 31, 2003 · General, Plastic Surgery
Device Facts
Record ID
K033671
Device Name
GORE BIOABSORBABLE MESH
Applicant
W. L. Gore & Associates, Inc.
Product Code
OWT · General, Plastic Surgery
Decision Date
Dec 31, 2003
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 878.3300
Device Class
Class 2
Attributes
Therapeutic
Intended Use
The GORE BIOABSORBABLE MESH is intended for use in the reinforcement of soft tissue. Examples of applications where the GORE BIOABSORBABLE MESH may be used include, but are not limited to: Hernia repair (inguinal, femoral, umbilical, abdominal, diaphragmatic, incisional, epigastric, gastroesophageal, hiatal, intermuscular). Muscle flap reinforcement Perforated tissue repair General tissue reconstruction's (periosteum, thoracic wall, reinforcement of the bladder wall, suture line reinforcement, tissue deficit, etc.)
Device Story
GORE BIOABSORBABLE MESH is a synthetic, microporous, bioabsorbable scaffold used to reinforce soft tissue and bridge defects. Composed of PGA:TMC copolymer fiber; device acts as a temporary bridge, stimulating native tissue ingrowth while gradually absorbing. Available in sheets and preformed 3D shapes; provided sterile for single use. Intended for surgical application by clinicians; requires an overlay patch for high-strength repairs like groin hernias. Benefits include defect filling and tissue reconstruction support during wound healing.
Clinical Evidence
Bench testing only. Device integrity testing was performed to demonstrate that the mesh meets specified requirements and is equivalent to predicate devices. No clinical data provided.
Technological Characteristics
Microporous structure; material: synthetic bioabsorbable poly (67% glycolide: 33% trimethylene carbonate) (PGA:TMC) copolymer fiber. Form factor: sheets and preformed 3D shapes. Sterilization: sterile, single-use.
Indications for Use
Indicated for reinforcement of soft tissue in patients requiring hernia repair (inguinal, femoral, umbilical, abdominal, diaphragmatic, incisional, epigastric, gastroesophageal, hiatal, intermuscular), muscle flap reinforcement, perforated tissue repair, and general tissue reconstruction (e.g., periosteum, thoracic wall, bladder wall, suture line reinforcement).
Regulatory Classification
Identification
Surgical mesh is a metallic or polymeric screen intended to be implanted to reinforce soft tissue or bone where weakness exists. Examples of surgical mesh are metallic and polymeric mesh for hernia repair, and acetabular and cement restrictor mesh used during orthopedic surgery.
Predicate Devices
SEAMGUARD Bioabsorbable Staple Line Reinforcement Material (K030782)
K191773 — GORE BIO-A Tissue Reinforcement · W. L. Gore & Associates, Inc. · Jul 31, 2019
K163217 — GORE BIO-A Tissue Reinforcement · W. L. Gore & Associates, Inc. · Feb 10, 2017
K222919 — GORE® ENFORM Biomaterial · W. L. Gore and Associates, Inc. · Dec 19, 2022
K173333 — GORE ENFORM Biomaterial · W. L. Gore & Associates, Inc. · Apr 5, 2018
K152609 — GORE SYNECOR Biomaterial · W. L. Gore & Associates, Inc. · Dec 11, 2015
Submission Summary (Full Text)
{0}------------------------------------------------
K033671 Page 1/3
GORE BIOABSORBABLE MESH
December 31, 2003
# 510(k) SUMMARY OF SUBSTANTIAL EQUIVALENCE
| Proprietary Name: | GORE BIOABSORBABLE MESH |
|------------------------------------|------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|
| Common Name: | Bioabsorbable Mesh |
| Classification Name: | Mesh, surgical, polymeric |
| Device Classification: | Class II |
| Product Classification and Code: | 878.3300, OWT, BWZ, OXC |
| Classification Panel: | General and Plastic Surgery Devices |
| Establishment Registration Number: | 3003910212 |
| Contact Person: | Michael J. Titus<br>Regulatory Affairs<br>Medical Products Division<br>W. L. Gore & Associates, Inc.<br>301 Airport Road<br>Elkton, Maryland 21922-1408<br>Telephone: (410) 506-8316<br>Facsimile: (410) 506-8221<br>E-mail: mtitus@wlgore.com |
## Performance Standards
Performance standards do not currently exist for these devices. None established under Section 514.
{1}------------------------------------------------
K033671 Page 2/3
510(k) Premarket Notification 510(k) Summary of Substantial Equivalence RE BIOABSORBABLE MESH
#### Device Description
The GORE BIOABSORBABLE MESH is used to reinforce soft tissue during the phases of wound healing by filling or bridging soft-tissue void spaces or defects. The GORE BIOABSORBABLE MESH elicits a physiological tissue response, which fills the defect with native tissue and gradually absorbs the device.
GORE® BIOABSORBABLE MESH is comprised of a microporous structure of synthetic bioabsorbable poly (67% glycolide: 33% trimethylene carbonate by weight) (PGA: TMC) copolymer fiber. This is the same material used in the predicate device (GORE DRAPEABLE ST Regenerative Membrane, K013346, cleared December 19, 2001 and SEAMGUARD, K030782 cleared April 21, 2003).
As packaged, the GORE BIOABSORBABLE MESH is a tailorable, bioabsorbable material intended to be a temporary bridge of defects until the absorptive nature of the device stimulates the body to fill the defect with native tissue. The device is available in sheets and preformed, three-dimensional shapes. The GORE BIOABSORBABLE MESH is provided STERILE for single use only.
Due to the absorptive nature of the GORE BIOABSORBABLE MESH, an overlay patch should be used in corrections requiring high strength (e.g., groin hernia repair)
#### Indication for Use
The GORE BIOABSORBABLE MESH is intended for use in the reinforcement of soft tissue. Examples of applications where the GORE BIOABSORBABLE MESH may be used include, but are not limited to:
The GORE BIOABSORBABLE MESH is intended for use in the reinforcement of soft tissue. Examples of applications where the GORE BIOABSORBABLE MESH may be used include, but are not limited to:
Hernia repair (inguinal, femoral, umbilical, abdominal, diaphragmatic, incisional, epigastric, gastroesophageal, hiatal, intermuscular).
Muscle flap reinforcement
Perforated tissue repair
General tissue reconstruction's (periosteum, thoracic wall, reinforcement of the bladder wall, suture line reinforcement, tissue deficit, etc.)
{2}------------------------------------------------
K033671 Page 3/3
GORE BIOABSORBABLE MESH
In W. L. Gore & Associates, Inc.'s opinion, the GORE BIOABSORBABLE MESH is believed to be substantially equivalent to the following predicate devices currently in interstate commerce with respect to comparable features, materials of construction and intended use.
- . SEAMGUARD Bioabsorbable Staple Line Reinforcement Material (W. L. Gore & Associates, Inc., Flagstaff, AZ) - K030782
- . GORE DRAPEABLE ST Regenerative Membrane (W.L. Gore & Associates, Inc., Flagstaff, AZ) - K013346
- . Vicryl (Ethicon Inc., Somerville, NJ) - K810428
- DePuy Restore® Orthobiologic Soft Tissue Implant (DePuy, Inc., . Warsaw, IN) - K001738
- . FortaGen (Organogenesis Inc., Canton, MA) - K021105
### Summary of Studies
W. L. Gore & Associates, Inc. performed device integrity testing to support that the GORE BIOABSORBABLE MESH is equivalent to the predicate devices. All device integrity test results for the GORE BIOABSORBABLE MESH met specified requirements.
## Conclusion (Statement of Equivalence)
Through data and information presented, numerous similarities support a determination of substantial equivalence, and therefore market clearance of the W. L. Gore & Associates, Inc. GORE BIOABSORBABLE MESH through this 510(k) Premarket Notification.
{3}------------------------------------------------
Image /page/3/Picture/1 description: The image contains the logo for the U.S. Department of Health & Human Services. The logo features the department's name in a circular arrangement around a stylized emblem. The emblem consists of a series of blue lines that form a human figure, with the lines representing different aspects of health and well-being. The text reads "DEPARTMENT OF HEALTH & HUMAN SERVICES · USA".
Food and Drug Administration 10903 New Hampshire Avenue Document Control Room -WO66-G609 Silver Spring, MD 20993-0002
W.L. Gore & Associates, Inc. Medical Products Division % Mr. Brandon Hansen, Regulatory Affairs 3450 West Kiltie Lane Flagstaff, Arizona 86002-0500
JUL - 2 2012
Re: K033671
Trade/Device Name: GORE Bioabsorbable Mesh Regulation Number: 878.3300 Regulation Name: Surgical Mesh Regulatory Class: II Product Code: OWT. OWZ. OXC Dated: November 21, 2003 Received: November 24, 2003
Dear Mr. Hansen:
This letter corrects our substantially equivalent letter of December 31, 2003.
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other
{4}------------------------------------------------
2-Mr. Brandon Hansen
requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please go to
http://www.fda.gov/AboutFDA/CentersOffices/CDRH/CDRHOffices/ucm115809.htm for the Center for Devices and Radiological Health's (CDRH's) Office of Compliance. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to
http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance.
You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/Resourcesfor You/Industry/default.htm.
Sincerely yours,
Mark N. Mello
Mark N. Melkerson Director Division of Surgical, Orthopedic and Restorative Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{5}------------------------------------------------
## Indications for Use
510(k) Number (if known): K033671
GORE® Bioabsorbable Mesh Device Name:
Indications For Use:
The GORE BIOABSORBABLE MESH is intended for use in the reinforcement of soft tissue. Examples of applications where the GORE BIOABSORBABLE MESH may be used include, but are not limited to:
Hernia repair (inguinal, femoral, umbilical, abdominal, diaphragmatic, incisional, epigastric, gastroesophageal, hiatal, intermuscular).
Muscle flap reinforcement
Perforated tissue repair
General tissue reconstruction's (periosteum, thoracic wall, reinforcement of the bladder wall, suture line reinforcement, tissue deficit, etc.)
Prescription Use × (Part 21 CFR 801 Subpart D)
AND/OR
Over-The-Counter Use (21 CFR 807 Subpart C)
(PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED)
Concurrence of CDRH, Office of Device Evaluation (ODE)
Daniel Krene for MMM
(Division Sign-Off)
(Division Sign-Off) Division of Surgical. Orthopedic. and Restorative Devices
510(k) Number K033671
Page
Panel 1
/
Sort by
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.