SOLOS 10MM OPERATING LAPAROSCOPE
Device Facts
| Record ID | K970917 |
|---|---|
| Device Name | SOLOS 10MM OPERATING LAPAROSCOPE |
| Applicant | Woodbine Optical Corp. |
| Product Code | GCJ · Gastroenterology, Urology |
| Decision Date | Jun 10, 1997 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 876.1500 |
| Device Class | Class 2 |
Indications for Use
to allow surgeons to view the interior cavities of the human body under direct vision through the scope for the purpose of performing surgery by general surgeons and thoracic surgeons.
Device Story
The Solos 10mm Operating Laparoscope is a rigid endoscopic device used by general and thoracic surgeons. It functions as an optical instrument allowing direct visualization of internal body cavities during surgical procedures. The device is operated by a surgeon in an operating room setting. It provides a visual pathway for the surgeon to perform minimally invasive surgical interventions. The device does not incorporate electronic sensors, software, or automated processing; it relies on traditional optical lens systems to transmit images to the surgeon's eye.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
10mm rigid operating laparoscope. Optical visualization system. Mechanical construction. No electronic components, software, or energy sources. Sterilization required per standard surgical instrument protocols.
Indications for Use
Indicated for general and thoracic surgeons to perform surgery by viewing interior human body cavities under direct vision through the scope.
Regulatory Classification
Identification
An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.
Special Controls
*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.
Related Devices
- K972984 — LERNER MEDICAL, INC. AUTOCLAVABLE 10 MM LAPAROSCOPE · Lerner Medical, Inc. · Oct 29, 1997
- K984434 — MEDIVISION LAPAROSCOPE · Medivision Scope Service Center, Inc. · Mar 17, 1999
- K955845 — LL 100, 103, 104 DIAGNOSTIC LAPAROSCOPE RIGID ROD LENS · Surgical Image Laboratories, Inc. · Jul 5, 1996
- K231003 — Laparoscope (21033FA, 21033FC, 21033WA, 21033WC, 20533FA, 20533FC, 20533WA, 20533WC) · Guangdong Optomedic Technologies, Inc. · Jul 6, 2023
- K992437 — SCHOELLY RIGID ENDOSCOPES · Fiber Imaging Technologies, Inc. · Sep 14, 1999