Viction Disposable Irrigation and suction catheter (VC-IRA0532, VC-IRA0523, VC-IRB0532, VC-IRB0523, VC-IRC0532, VC-IRC0523, VC-IRD0532, VC-IRD0532)

K250124 · Hangzhou Viction Medical Technology Co.,Ltd · GCJ · Aug 6, 2025 · Gastroenterology, Urology

Device Facts

Record IDK250124
Device NameViction Disposable Irrigation and suction catheter (VC-IRA0532, VC-IRA0523, VC-IRB0532, VC-IRB0523, VC-IRC0532, VC-IRC0523, VC-IRD0532, VC-IRD0532)
ApplicantHangzhou Viction Medical Technology Co.,Ltd
Product CodeGCJ · Gastroenterology, Urology
Decision DateAug 6, 2025
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 876.1500
Device ClassClass 2

Indications for Use

The Viction disposable Irrigation and suction Catheter is indicated for use in conjunction with the handpiece, dual tubing, and probes to provide controlled powered irrigation during Laparoscopic surgery.

Device Story

Device is a battery-powered, single-use, disposable suction and irrigation system for laparoscopic surgery. System comprises a handpiece, dual tubing (suction and irrigation), and probes. Operates via a mechanical pump powered by nine AA alkaline batteries; irrigation flow is controlled by a button on the handpiece. Suction function requires connection to hospital-provided negative pressure source. Used in clinical/hospital settings by healthcare professionals. Provides controlled fluid delivery to surgical sites and suction capability to clear fluids. Benefits include improved visualization and site management during minimally invasive procedures.

Clinical Evidence

No clinical data provided. Substantial equivalence supported by bench testing, including fluid flow rate, negative pressure resistance, sealing performance, electrical safety, EMC, and biocompatibility testing (acute systemic toxicity, skin sensitization, intracutaneous reactivity, pyrogen, and in vitro cytotoxicity).

Technological Characteristics

Materials: 304 Stainless Steel, ABS, PVC. Energy source: 9 AA alkaline batteries. Principle: Battery-powered mechanical pumping system. Form factor: Handpiece with dual tubing and probes. Connectivity: None. Sterilization: Ethylene Oxide (SAL 10^-6). Standards: IEC 60601-1 (safety), IEC 60601-1-2 (EMC), ISO 10993-1 (biocompatibility).

Indications for Use

Indicated for patients undergoing laparoscopic surgery requiring controlled powered irrigation.

Regulatory Classification

Identification

An endoscope and accessories is a device used to provide access, illumination, and allow observation or manipulation of body cavities, hollow organs, and canals. The device consists of various rigid or flexible instruments that are inserted into body spaces and may include an optical system for conveying an image to the user's eye and their accessories may assist in gaining access or increase the versatility and augment the capabilities of the devices. Examples of devices that are within this generic type of device include cleaning accessories for endoscopes, photographic accessories for endoscopes, nonpowered anoscopes, binolcular attachments for endoscopes, pocket battery boxes, flexible or rigid choledochoscopes, colonoscopes, diagnostic cystoscopes, cystourethroscopes, enteroscopes, esophagogastroduodenoscopes, rigid esophagoscopes, fiberoptic illuminators for endoscopes, incandescent endoscope lamps, biliary pancreatoscopes, proctoscopes, resectoscopes, nephroscopes, sigmoidoscopes, ureteroscopes, urethroscopes, endomagnetic retrievers, cytology brushes for endoscopes, and lubricating jelly for transurethral surgical instruments. This section does not apply to endoscopes that have specialized uses in other medical specialty areas and that are covered by classification regulations in other parts of the device classification regulations.

Special Controls

*Classification* —(1)*Class II (special controls).* The device, when it is an endoscope disinfectant basin, which consists solely of a container that holds disinfectant and endoscopes and accessories; an endoscopic magnetic retriever intended for single use; sterile scissors for cystoscope intended for single use; a disposable, non-powered endoscopic grasping/cutting instrument intended for single use; a diagnostic incandescent light source; a fiberoptic photographic light source; a routine fiberoptic light source; an endoscopic sponge carrier; a xenon arc endoscope light source; an endoscope transformer; an LED light source; or a gastroenterology-urology endoscopic guidewire, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 876.9.(2) Class I for the photographic accessories for endoscope, miscellaneous bulb adapter for endoscope, binocular attachment for endoscope, eyepiece attachment for prescription lens, teaching attachment, inflation bulb, measuring device for panendoscope, photographic equipment for physiologic function monitor, special lens instrument for endoscope, smoke removal tube, rechargeable battery box, pocket battery box, bite block for endoscope, and cleaning brush for endoscope. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807of this chapter, subject to the limitations in § 876.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD & DRUG ADMINISTRATION August 6, 2025 Hangzhou Viction Medical Technology Co.,Ltd Zhicong Luo General Manager First Floor ,No.1 Building, No.95 Binwen Road, Binjiang District Hangzhou, Zhejiang 310051 China Re: K250124 Trade/Device Name: Viction Disposable Irrigation and suction catheter (VC-IRA0532, VC-IRA0523, VC-IRB0532, VC-IRB0523, VC-IRC0532, VC-IRC0523, VC-IRD0532, VC-IRD0532) Regulation Number: 21 CFR 876.1500 Regulation Name: Endoscope And Accessories Regulatory Class: Class II Product Code: GCJ Dated: January 17, 2025 Received: January 17, 2025 Dear Zhicong Luo: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. U.S. Food & Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K250124 - Zhicong Luo Page 2 If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn {2} K250124 - Zhicong Luo Page 3 (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, ![img-0.jpeg](img-0.jpeg) Julie Morabito, Ph.D. Director DHT4A: Division of General Surgery Devices OHT4: Office of Surgical and Infection Control Devices Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Indications for Use Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. Submission Number (if known) k250124 Device Name Viction Disposable Irrigation and suction catheter (VC-IRA0532、VC-IRA0523、VC-IRB0532、VC-IRB0523VC-IRC0532、VC-IRC0523、VC-IRD0532、VC-IRD0532) Indications for Use (Describe) The Viction disposable Irrigation and suction Catheter is indicated for use in conjunction with the handpiece, dual tubing, and probes to provide controlled powered irrigation during Laparoscopic surgery. Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) ## CONTINUE ON A SEPARATE PAGE IF NEEDED. This section applies only to requirements of the Paperwork Reduction Act of 1995. *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {4} 510 (K) Summary K250124 This summary of 510(K)safety and effectiveness information is being submitted in accordance with the requirements of 21 CFR §807.92. Type of submission : Traditional The date the summary was prepared: June8, 2025 I. SUBMITTER Hangzhou Viction Medical Technology Co.,Ltd First floor, No.1 Building, No.95 Binwen Road, Binjiang District, Hangzhou City, Zhejiang Province, China.MD310051 Contact Person: Yu Gu Phone:+86-057188305089 Email:guyu@victionmed.com Date Prepared: February 11, 2025 II. Device Name of Device : Viction Disposable Suction Irrigation Catheter, (VC-IRA0532, VC-IRA0523, VC-IRB0532, VC-IRB0523, VC-IRC0532,VC-IRC0523,VC-IRD0532, VC-IRD0532) Common or Usual Name: Suction Irrigation Catheter Classification Name:Endoscope And Accessories( 21 CFR876.1500 ) Regulatory Class: 2 Product Code: GCJ III. PREDICATE DEVICE CORE E3 Suction/Irrigator (K202303), manufactured by ConMed Corporation. Located in 525 French Road Utica. This predicate has not been subjected to a design-related recall. No reference devices were used in this submission. IV. DEVICE DESCRIPTION The Viction Disposable Irrigation and suction Catheter is constitutes with Suction/irrigation handpiece, dual tubing, Irrigation device that is a battery-powered mechanical pumping system connect with dual tubing(suction tubing and irrigation tubing) to deliver sterile fluids to surgical sites. Control of the irrigation flow is generated by depressing the on-off Control Button on the handpiece. The mechanical pumping system is powered with nine(9) standard AAlkaline Battery. {5} Hand piece equipped with pistol style attach to Suction irrigation probes and suction tubing. And it should be used with negative pressure device of the hospital. There are 8 models of the product, models VC-IRA0532, VC-IRA0523, VC-IR B0532, VC-IRB0523, VC-IRC0532, VC-IRC0523, VC-IRD0532, VC-IRD0532. All product's Structure are the same, the length of the irrigation suction tubes is the main difference. It is a single use, disposable device and is sold sterile. ## V. INDICATION FOR USE The Viction Disposable Irrigation and Suction Catheter is indicated for use in conjunction with the handpiece, dual tubing, and probes to provide controlled powered irrigation during Laparoscopic surgery. ## VI. COMPARISON OF TECHNOLOGICAL CHARACTERISTICS ## WITH THE PREDICATED DEVICE The Viction Disposable Suction Irrigation system is compared with the following Predicate Devices in terms of intended use, design, material, specifications, and performance. **Predicate device name**: CORE E3 Suction/Irrigator **510(K) number**: K202303 **Common Name**: Suction Irrigation **Manufacturer**: ConMed Corporation. The following table shows similarities and differences of indications for use between our device and the predicate devices. Differences between the devices cited in this section do not raise any new issues of safety or effectiveness. | Item | Predicate device | Subject device | Comparison | | --- | --- | --- | --- | | Trade Name | CORE E3 Suction/Irrigator | Viction Disposable Irrigation and suction catheter | Similar product, different name | | 510(K) Number | K202303 | K250124 | / | | Classification regulation | 21 CFR 876.1500 | 21 CFR 876.1500 | same | | Classification and Code | ClassII, GCJ | ClassII, GCJ | same | {6} | Device Classification Name | Laparoscope, General & Plastic Surgery | Laparoscope, General & Plastic Surgery | same | | --- | --- | --- | --- | | Design | Battery-powered pump, dual tubing, trumpet handpiece, and optional probe. | Battery-powered pump, dual tubing, handpiece, and four types of probe. | Different; subject device’s probe has different shapes, but it can’t change, do not have optional Probes. | | materials | 304 Stainless Steel, Polycarbonate, 420 Stainless Steel, EPDM Rubber, ABS, and PVC. Six (6) AAA alkaline batteries. | 304 Stainless Steel, ABS, and PVC. Nine (9) AA alkaline batteries. | Similar | | Sterilization | Ethylene Oxide Sterility Assurance Level (SAL) of 10^{-6} | Ethylene Oxide Sterility Assurance Level (SAL) of 10^{-6} | | | Single Use / Reusable | Single Use | Single Use | same | | Principle of Operation | Battery powered mechanical pumping system | Battery powered mechanical pumping system | same | | Environment Use | Healthcare facility/hospital | Healthcare facility/hospital | same | ## Conclusion Based on the comparison of indications of use and other product performances. The Viction Disposable Suction Irrigation system manufactured by “Hangzhou Viction Medical Technology Co., Ltd.” is substantial equivalent to its predicate devices. ## VII. PERFORMANCE DATA The following performance data were provided in support of the substantial equivalence determination. ### Electrical safety and electromagnetic compatibility Electrical safety and EMC testing were conducted on the device. Electromagnetic compatibility is evaluated following IEC 60601-1-2:2014+AMD {7} 1:2020,IEC 60601-2-18:2009. Electrical safety is evaluated following IEC 60601-1: 2005: Medical electrical equipment – Part 1: General requirements for basic safety and essential performance. Apply with standard IEC606011:2005+AMD1:2012+AMD2:2020 ## Biocompatibility testing The Biocompatibility evaluation for the CORE E3 device was conducted in accordance with ISO 10993-1:2018 Biological evaluation of medical devices – Part-1: Evaluation and testing within a risk management process and application of applicable principles detailed in FDA Guidance Use of International Standard ISO 10993-1, "Biological evaluation of medical devices – Part 1: Evaluation and Testing within a Risk Management Process" (June 16, 2016). The following tests were completed: - Acute Systemic Toxicity - Skin Sensitization Test - Intracutaneous Reactivity Test - Pyrogen Test - In Vitro Cytotoxicity Test ## Bench Testing - Fluid flow rate of Irrigation tube - Negative pressure resistance of suction - Sealing of irrigation tube ## Sterilization Performance qualification for ethylene oxide sterilization ## Clinical Testing Not applicable to this submission All the test results meets the predefined acceptance criteria and complied with the design specification of the subject device throughout the use life. The results of the non-clinical testing demonstrate that the victim disposable irrigation and suction catheter is as safe and effective as the predicate device. ## VIII. CONCLUSIONS Based upon the intended use and known technical information provided in this pre-market notification the Viction Disposable Irrigation and Suction Catheter has been shown to be substantially equivalent to currently marketed predicate device K202303.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...