ULTRACISION 5MM HARD SHEATH LAPAROSONIC BLADE

K962584 · Ethicon Endo-Surgery, Inc. · LFL · Nov 4, 1996 · SU

Device Facts

Record IDK962584
Device NameULTRACISION 5MM HARD SHEATH LAPAROSONIC BLADE
ApplicantEthicon Endo-Surgery, Inc.
Product CodeLFL · SU
Decision DateNov 4, 1996
DecisionSESE
Submission TypeTraditional
Device ClassClass U
AttributesTherapeutic

Intended Use

The intended use for the New Device is the same as that of the Predicate Device in that it is for cutting soft tissue and providing hemostasis during endoscopic surgery.

Device Story

UltraCision 5mm Hard Sheath LaparoSonic Blade instruments (Sharp Hook, Dissecting Hook, Ball Coagulator styles); sterile, single-patient use. System includes titanium blade with non-removable sheath, hand piece, blade adaptor, wrench, generator, foot switch, and cart. Used in endoscopic surgery by physicians for soft tissue cutting and hemostasis. Ultrasonic energy provides cutting and coagulation; serves as alternative to electrosurgery, lasers, or steel scalpels. Benefits include precise cutting with minimal thermal injury.

Clinical Evidence

Bench testing only. Pre-clinical laboratory evaluations demonstrated acceptable performance in cutting, blunt tissue dissection, and coagulation.

Technological Characteristics

Titanium blade; non-removable sheath; 32 cm working length. Ultrasonic activation principle. System includes generator, hand piece, and foot switch. Sterile, single-patient use.

Indications for Use

Indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. Can be used as an adjunct to or substitute for electrosurgery, lasers, and steel scalpels in endoscopic surgery.

Related Devices

Submission Summary (Full Text)

{0} NOV - 4 1996 K 962584 # Appendix A ## 510(k) Summary of Safety and Effectiveness | Statement | Information supporting claims of substantial equivalence, as defined under the Federal Food, Drug and Cosmetic Act, respecting safety and effectiveness is summarized below. For the convenience of the Reviewer, this summary is formatted in accordance with the Agency’s final rule ”...510(k) Summaries and 510(k) Statements...” (21 CFR § 807) and can be used to provide a substantial equivalence summary to anyone requesting it from the Agency. | | --- | --- | | Device description | The UltraCision 5mm Hard Sheath LaparoSonic® Blade instruments are 3 styles of sterile, single patient use instruments consisting of a titanium blade with a non-removable sheath. The three styles consist of a Sharp Hook, Dissecting Hook and a Ball Coagulator. The working lengths are approximately 32 cm. The system consists of a blade affixed with a sheath, a hand piece, blade adaptor, blade wrench, generator, foot switch and cart. | | Intended use | The intended use for the New Device is the same as that of the Predicate Device in that it is for cutting soft tissue and providing hemostasis during endoscopic surgery. | | Indications statement | The UltraCision 5mm Hard Sheath LaparoSonic® Blade is indicated for soft tissue incisions when bleeding control and minimal thermal injury are desired. The instruments can be used as an adjunct to or substitute for electrosurgery, lasers, and steel scalpels. | | Technological characteristics | The technological characteristics of the New Devices are the same as the Predicate Device. The same ultrasonic characteristics remain as a method of activation. | | Performance data | Pre-clinical laboratory evaluations were performed to ensure that the device can be used as designed. The studies demonstrated acceptable performance in cutting, blunt tissue dissection and coagulation. | Continued on next page {1} 510(k) Summary of Safety and Effectiveness, Continued | Conclusion | Based on the 510(k) summaries and 510(k) statements (21 CFR §807) and the information provided herein, we conclude that the New Devices are substantially equivalent to the Predicate Device under the Federal Food, Drug and Cosmetic Act. | | --- | --- | | Contact | Lonnie Pace Ethicon Endo-Surgery, Inc. 4545 Creek Road Cincinnati, Ohio 45242 | | Date | June 27, 1996 | 29
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...