Synapse PACS (7.5)

K243647 · FUJIFILM Healthcare Americas Corporation · QIH · Jun 30, 2025 · Radiology

Device Facts

Record IDK243647
Device NameSynapse PACS (7.5)
ApplicantFUJIFILM Healthcare Americas Corporation
Product CodeQIH · Radiology
Decision DateJun 30, 2025
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.2050
Device ClassClass 2
AttributesAI/ML, Software as a Medical Device

Intended Use

FUJIFILM Synapse PACS Software is intended for use as a web-based application on an off-the shelf PC which meets or exceeds minimum specifications and is networked with a FUJIFILM Synapse PACS server. The FUJIFILM Synapse PACS Software can process medical images from DICOM compliant modalities and non-DICOM sources. FUJIFILM Synapse PACS Software provides toolsets for: Performing measurements on DICOM images Regional segmentation Importing and presenting data from modalities (DICOM and non-DICOM), Solving clinical calculations Creating and distributing structured reports FUJIFILM Synapse PACS Software is intended to serve as the primary user interface for the processing of medical images for presentation on displays appropriate to the medical task being performed. It enables the display, comparison, fusion, and volume rendering of studies to aid in reading, interpreting, reporting, and treatment planning. Typical users are radiologists, cardiologists, technologists, sonographers, technicians, nurses, and clinicians. MIP, MPR Fusion, and volume rendering are not intended for mammography use. FUJIFILM Synapse PACS Software can be used to process FUJIFILM’s DICOM MG “For Processing” images and also for the display, manipulation, and interpretation of lossless compressed or non-compressed mammography images that have been received in the DICOM For Presentation format and displayed on FDA-cleared, DICOM compatible displays for mammography.

Device Story

Synapse PACS (7.5) is an enterprise-wide medical image management software (SaMD) running on off-the-shelf PCs. It ingests DICOM and non-DICOM medical images; provides tools for measurement, regional segmentation, clinical calculations, and structured reporting. Key features include volume rendering, 3D tools, 2-point VOI (semi-automatic lesion segmentation), and AI-based bone removal. Used in clinical settings by radiologists, cardiologists, and technologists to facilitate image interpretation and treatment planning. The device integrates algorithms previously cleared in Synapse 3D (K221677). Output is presented on clinical displays; aids clinicians in diagnostic reading and reporting. Benefits include enhanced visualization of vessels via bone masking and streamlined 3D analysis workflows.

Clinical Evidence

Bench testing only. Performance of the bone extraction algorithm was validated using 72 patient images (35 male, 37 female; ages 22-120) from Siemens, GE, and Philips scanners. Primary endpoint: Dice Similarity Coefficient (DSC); secondary: 95% Hausdorff Distance (HD). Mean DSC was 0.959 [0.955–0.963], exceeding the 0.951 threshold. Mean 95% HD was 1.367 mm [1.170–1.563 mm], within the 0.98–7.31 mm range. Ground truth established via dual-reader consensus by board-certified radiologists.

Technological Characteristics

Web-based SaMD running on off-the-shelf PC hardware. Features include DICOM/non-DICOM image processing, volume rendering, 3D tools, and AI-based bone removal. Connectivity via network to Synapse PACS server. Software-based segmentation and rendering algorithms.

Indications for Use

Indicated for use by radiologists, cardiologists, technologists, sonographers, technicians, nurses, and clinicians for processing, displaying, comparing, and interpreting medical images (DICOM/non-DICOM) to aid in treatment planning and reporting. Not intended for mammography use regarding MIP, MPR Fusion, and volume rendering.

Regulatory Classification

Identification

A medical image management and processing system is a device that provides one or more capabilities relating to the review and digital processing of medical images for the purposes of interpretation by a trained practitioner of disease detection, diagnosis, or patient management. The software components may provide advanced or complex image processing functions for image manipulation, enhancement, or quantification that are intended for use in the interpretation and analysis of medical images. Advanced image manipulation functions may include image segmentation, multimodality image registration, or 3D visualization. Complex quantitative functions may include semi-automated measurements or time-series measurements.

Special Controls

*Classification.* Class II (special controls; voluntary standards—Digital Imaging and Communications in Medicine (DICOM) Std., Joint Photographic Experts Group (JPEG) Std., Society of Motion Picture and Television Engineers (SMPTE) Test Pattern).

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0} FDA U.S. FOOD & DRUG ADMINISTRATION FUJIFILM Healthcare Americas Corporation Kulkarni Chaitrali Sr. Regulatory Affairs Specialist 81 Hartwell Ave Suite 300 LEXINGTON, MASSACHUSETTS 02421 June 30, 2025 Re: K243647 Trade/Device Name: Synapse PACS (7.5) Regulation Number: 21 CFR 892.2050 Regulation Name: Medical Image Management And Processing System Regulatory Class: Class II Product Code: QIH Dated: June 3, 2025 Received: June 3, 2025 Dear Kulkarni Chaitrali: We have reviewed your section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (the Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. Although this letter refers to your product as a device, please be aware that some cleared products may instead be combination products. The 510(k) Premarket Notification Database available at https://www.accessdata.fda.gov/scripts/cdrh/cfdocs/cfpmn/pmn.cfm identifies combination product submissions. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. U.S. Food & Drug Administration 10903 New Hampshire Avenue Silver Spring, MD 20993 www.fda.gov {1} K243647 - Kulkarni Chaitrali Page 2 Additional information about changes that may require a new premarket notification are provided in the FDA guidance documents entitled "Deciding When to Submit a 510(k) for a Change to an Existing Device" (https://www.fda.gov/media/99812/download) and "Deciding When to Submit a 510(k) for a Software Change to an Existing Device" (https://www.fda.gov/media/99785/download). Your device is also subject to, among other requirements, the Quality System (QS) regulation (21 CFR Part 820), which includes, but is not limited to, 21 CFR 820.30, Design controls; 21 CFR 820.90, Nonconforming product; and 21 CFR 820.100, Corrective and preventive action. Please note that regardless of whether a change requires premarket review, the QS regulation requires device manufacturers to review and approve changes to device design and production (21 CFR 820.30 and 21 CFR 820.70) and document changes and approvals in the device master record (21 CFR 820.181). Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device-related adverse events) (21 CFR Part 803) for devices or postmarketing safety reporting (21 CFR Part 4, Subpart B) for combination products (see https://www.fda.gov/combination-products/guidance-regulatory-information/postmarketing-safety-reporting-combination-products); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820) for devices or current good manufacturing practices (21 CFR Part 4, Subpart A) for combination products; and, if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR Parts 1000-1050. All medical devices, including Class I and unclassified devices and combination product device constituent parts are required to be in compliance with the final Unique Device Identification System rule ("UDI Rule"). The UDI Rule requires, among other things, that a device bear a unique device identifier (UDI) on its label and package (21 CFR 801.20(a)) unless an exception or alternative applies (21 CFR 801.20(b)) and that the dates on the device label be formatted in accordance with 21 CFR 801.18. The UDI Rule (21 CFR 830.300(a) and 830.320(b)) also requires that certain information be submitted to the Global Unique Device Identification Database (GUDID) (21 CFR Part 830 Subpart E). For additional information on these requirements, please see the UDI System webpage at https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/unique-device-identification-system-udi-system. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to https://www.fda.gov/medical-devices/medical-device-safety/medical-device-reporting-mdr-how-report-medical-device-problems. For comprehensive regulatory information about medical devices and radiation-emitting products, including information about labeling regulations, please see Device Advice (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance) and CDRH Learn (https://www.fda.gov/training-and-continuing-education/cdrh-learn). Additionally, you may contact the Division of Industry and Consumer Education (DICE) to ask a question about a specific regulatory topic. See {2} K243647 - Kulkarni Chaitrali Page 3 the DICE website (https://www.fda.gov/medical-devices/device-advice-comprehensive-regulatory-assistance/contact-us-division-industry-and-consumer-education-dice) for more information or contact DICE by email (DICE@fda.hhs.gov) or phone (1-800-638-2041 or 301-796-7100). Sincerely, ![img-0.jpeg](img-0.jpeg) Jessica Lamb, PhD Assistant Director Imaging Software Team DHT8B: Division of Radiologic Imaging Devices and Electronic Products OHT8: Office of Radiological Health Office of Product Evaluation and Quality Center for Devices and Radiological Health Enclosure {3} DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration Form Approved: OMB No. 0910-0120 Expiration Date: 07/31/2026 See PRA Statement below. # Indications for Use ## Submission Number (if known) K243647 ## Device Name Synapse PACS (7.5) ## Indications for Use (Describe) FUJIFILM Synapse PACS Software is intended for use as a web-based application on an off-the shelf PC which meets or exceeds minimum specifications and is networked with a FUJIFILM Synapse PACS server. The FUJIFILM Synapse PACS Software can process medical images from DICOM compliant modalities and non-DICOM sources. FUJIFILM Synapse PACS Software provides toolsets for: - Performing measurements on DICOM images - Regional segmentation - Importing and presenting data from modalities (DICOM and non-DICOM), - Solving clinical calculations - Creating and distributing structured reports FUJIFILM Synapse PACS Software is intended to serve as the primary user interface for the processing of medical images for presentation on displays appropriate to the medical task being performed. It enables the display, comparison, fusion, and volume rendering of studies to aid in reading, interpreting, reporting, and treatment planning. Typical users are radiologists, cardiologists, technologists, sonographers, technicians, nurses, and clinicians. MIP, MPR Fusion, and volume rendering are not intended for mammography use. FUJIFILM Synapse PACS Software can be used to process FUJIFILM’s DICOM MG “For Processing” images and also for the display, manipulation, and interpretation of lossless compressed or non-compressed mammography images that have been received in the DICOM For Presentation format and displayed on FDA-cleared, DICOM compatible displays for mammography. Type of Use (Select one or both, as applicable) ☑ Prescription Use (Part 21 CFR 801 Subpart D) ☐ Over-The-Counter Use (21 CFR 801 Subpart C) CONTINUE ON A SEPARATE PAGE IF NEEDED. {4} | 510(k) #: K243647 | 510(k) Summary | Prepared on: 2025-06-23 | | --- | --- | --- | | Contact Details | | 21 CFR 807.92(a)(1) | | Applicant Name | FUJIFILM Healthcare Americas Corporation | | | Applicant Address | 81 Hartwell Ave Suite 300 Lexington MA 02421 United States | | | Applicant Contact Telephone | 704-517-4886 | | | Applicant Contact | Ms. Kulkarni Chaitrali | | | Applicant Contact Email | hcusregulatoryaffairs@fujifilm.com | | | Device Name | | 21 CFR 807.92(a)(2) | | Device Trade Name | Synapse PACS (7.5) | | | Common Name | Medical image management and processing system | | | Classification Name | Automated Radiological Image Processing Software | | | Regulation Number | 892.2050 | | | Product Code(s) | QIH | | | Legally Marketed Predicate Devices | | 21 CFR 807.92(a)(3) | | Predicate # | Predicate Trade Name (Primary Predicate is listed first) | Product Code | | K190232 | Synapse PACS | LLZ | | K221677 | Synapse 3D Base Tools v6.6 | LLZ | | Device Description Summary | | 21 CFR 807.92(a)(4) | | The Synapse PACS is an enterprise-wide medical information and image management software that runs on standard “off-the-shelf” PC hardware and Software (OS, browser). Synapse is intended for communication, storage, display, manipulation, measurement, printing, and processing of images and information acquired from various medical imaging and information systems. As a Software as a Medical Device (SaMD), Synapse PACS performs these purposes without being part of a hardware medical device. | | | | Intended Use/Indications for Use | | 21 CFR 807.92(a)(5) | | FUJIFILM Synapse PACS Software is intended for use as a web-based application on an off-the shelf PC which meets or exceeds minimum specifications and is networked with a FUJIFILM Synapse PACS server. The FUJIFILM Synapse PACS Software can process medical images from DICOM compliant modalities and non-DICOM sources. FUJIFILM Synapse PACS Software provides toolsets for: • Performing measurements on DICOM images • Regional segmentation • Importing and presenting data from modalities (DICOM and non-DICOM), • Solving clinical calculations • Creating and distributing structured reports | | | {5} FUJIFILM Synapse PACS Software is intended to serve as the primary user interface for the processing of medical images for presentation on displays appropriate to the medical task being performed. It enables the display, comparison, fusion, and volume rendering of studies to aid in reading, interpreting, reporting, and treatment planning. Typical users are radiologists, cardiologists, technologists, sonographers, technicians, nurses, and clinicians. MIP, MPR Fusion, and volume rendering are not intended for mammography use. FUJIFILM Synapse PACS Software can be used to process FUJIFILM's DICOM MG "For Processing" images and also for the display, manipulation, and interpretation of lossless compressed or non-compressed mammography images that have been received in the DICOM For Presentation format and displayed on FDA-cleared, DICOM compatible displays for mammography. ## Indications for Use Comparison 21 CFR 807.92(a)(5) There are no differences in the indication for use between the subject device and the primary predicate device. ## Technological Comparison 21 CFR 807.92(a)(6) The differences between the features in the subject device and the primary predicate device are Volume Rendering Techniques, 3D Tools, Bone Removal, and 2-Point VOI. Although the primary predicate device does not have the features listed, the reference device have the same features. Because the predicate device and reference device contain the same features, the addition of the features in version 7.5 do not affect the safety or efficacy of the subject device. ## Non-Clinical and/or Clinical Tests Summary & Conclusions 21 CFR 807.92(b) Non-clinical testing result: The differences between the features in the subject device and the primary predicate device are Volume Rendering Techniques including 3D Tools, 2-Point Volume of Interest (VOI), and Bone Removal. The key addition to Synapse PACS 7.5.0 is the ability to perform volume rendering and 3D volume viewing for CT and MR. The algorithm is already cleared and marketed for Synapse 3D (K221677, reference device). The volume rendering algorithms were integrated unchanged into Synapse PACS 7.5.0 (subject device). The 2-point VOI performs is a semi-automatic segmentation of a lesion in CT and MRI images using the line drawn by the user on the lesion. The algorithm implemented is the same as already cleared and marketed algorithms for Synapse 3D (K221677, reference device). In Synapse3D, it is called Tumor Boundary Segmentation algorithm. The algorithm has been integrated into Synapse PACS unchanged compared to Synapse 3D. Comparison with Synapse 3D (K221677, reference device) provides the same results in Synapse PACS 7.5.0 (subject device). Bone Removal is a tool that enhances the visibility of vessels in 3D rendered images by masking out bone regions. The tool is based on an AI algorithm cleared and marketed for Synapse 3D (K221677, reference device). It was improved for Synapse PACS 7.5.0. Comparison with Synapse 3D (K221677, reference device) showed that the improved algorithm does not affect the safety or efficacy of Synapse PACS 7.5.0 (subject device). Please refer to the Performance Bench Testing for testing with the improved algorithm. Performance Testing Summary A. Summary test statistics and acceptance criteria: Dice Similarity Coefficient (DSC) and 95% Hausdorff Distance (HD) were used as primary and secondary endpoints to validate the performance of bone extraction algorithm. A pre-defined acceptance threshold of 0.951 was used for DSC. For 95% HD, we pre-define acceptance range 0.98 mm – 7.31 mm. The thresholds are determined after reviewing existing bone removal models in the literature. The mean observed dice overlap coefficient and 95% HD with 95% confidence intervals were 0.959 [0.955 – 0.963] and 1.367 mm [1.170 mm – 1.563 mm], respectively, exceeding the predefined acceptance thresholds. Across the subgroups—region, sex, age band, vendor, slice-thickness bin, body region, contrast—Dice values remained tightly clustered between 0.94 and 0.97 and 95% HD never exceeded 2.57 mm. The 5 mm cohort shows a slightly lower Dice (0.942) because thick slices compress bone detail into fewer voxels, so tiny absolute deviations inflate the overlap metric; the boundary error remains modest (HD = 2.6 mm), confirming clinically acceptable performance. {6} B. The number of individual patient's images were collected from. Images from 72 patients were collected, each patient had one image collected. C. Demographic Distribution Gender: 35 Males, 37 Females Ages: 16 patients from ages 22-34 27 patients from ages 35-64 29 patients from ages 65-120 Regions: 20 patients from Midwest 20 patients from Southwest 32 patients from the Southeast D. Information about image regions and confounders present in the dataset Head/Neck: 16 images Chest/Abdomen: 25 images Abdomen/Pelvic: 19 images Extremities: 6 images Vascular/Others: 6 images E. Information about equipment and protocols used to collect images Images were collected from the following manufacturers: 28 SIEMENS, 22 GE, and 22 Philips Slice thickness: ≤1.25mm: 29 images 1.25-2.5mm: 20 images 2.5-5.0mm: 23 images ≥5mm: 6 images Contrast agent: Contrast: 50 images Non-contrast: 22 images F. Information about how the reference standard was derived from the dataset (i.e., the "truthing" process) An initial bone mask was created by certified technologist, then subjected to an independent dual-reader consensus review: two U.S. board-certified radiologists independently evaluated the mask, recorded any discrepancies, and iteratively reconciled them until consensus was achieved. The resulting consensus mask serves as the definitive ground truth for performance testing.