CHAMPION 5000 PERIPHERAL VASCULAR COIL

K023247 · Usa Instruments, Inc. · MOS · Dec 23, 2002 · Radiology

Device Facts

Record IDK023247
Device NameCHAMPION 5000 PERIPHERAL VASCULAR COIL
ApplicantUsa Instruments, Inc.
Product CodeMOS · Radiology
Decision DateDec 23, 2002
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 892.1000
Device ClassClass 2

Intended Use

The Champion 5000 Peripheral Vascular Coil is a multi-element phased array RF coil, used for obtaining diagnostic images of the vasculature and soft tissue anatomy extending from the torso to the foot region, in Magnetic Resonance Imaging Systems. The Champion 5000 Peripheral Vascular Coil is designed for use with the Altaire 0.7T MRI system manufactured by Hitachi Medical Systems America, Inc. The indications for use are the same as for standard MR Imaging.

Device Story

Champion 5000 Peripheral Vascular Coil; multi-element phased array receive-only RF coil; used with Hitachi Altaire 0.7T MRI system. Input: hydrogen nuclei signals from patient anatomy (torso to foot). Operation: receive-only coil; decoupling via switching diodes isolates elements during RF transmission; rigid fire-rated plastic housing. Output: raw MR signal data processed by host MRI system into diagnostic images. Used in clinical MRI settings; operated by trained MRI technologists/physicians. Benefits: open design minimizes claustrophobia; improves patient comfort during vascular/soft tissue imaging. Output used by physicians for diagnostic determination.

Clinical Evidence

Bench testing only. No clinical data provided. Safety and effectiveness established through comparison of design, materials, and functional characteristics (decoupling, RF safety) to legally marketed predicate devices.

Technological Characteristics

Multi-element phased array receive-only RF coil. Materials: Flame retardant polycarbonate and flame retardant polyurethane (TD-27702, Polyone U2773 Neutral). Decoupling: Switching diode. Energy: Passive receive-only (no RF transmission). Form factor: Five-section rigid housing (main base, three top sections, one foot section). Connectivity: Dedicated interface for Hitachi Altaire 0.7T MRI system.

Indications for Use

Indicated for patients requiring diagnostic MRI imaging of vasculature and soft tissue anatomy from torso to foot. Compatible with Hitachi Altaire 0.7T MRI systems. Contraindications: standard MRI contraindications apply.

Regulatory Classification

Identification

A magnetic resonance diagnostic device is intended for general diagnostic use to present images which reflect the spatial distribution and/or magnetic resonance spectra which reflect frequency and distribution of nuclei exhibiting nuclear magnetic resonance. Other physical parameters derived from the images and/or spectra may also be produced. The device includes hydrogen-1 (proton) imaging, sodium-23 imaging, hydrogen-1 spectroscopy, phosphorus-31 spectroscopy, and chemical shift imaging (preserving simultaneous frequency and spatial information).

Special Controls

*Classification.* Class II (special controls). A magnetic resonance imaging disposable kit intended for use with a magnetic resonance diagnostic device only is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 892.9.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K823247 ## DEC 2 3 2002 ## SUMMARY OF SAFETY AND EFFECTIVENESS | 1. Device Name: | Magnetic Resonance Imaging Accessory | |------------------------------------|-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | 2. Proprietary Name: | Champion 5000 Peripheral Vascular Coil | | 3. Classification: | Class II | | 4. Establishment Registration #: | 1529041 | | 5. Manufacture Facility Location: | USA Instruments, Inc.,<br>1515 Danner Drive<br>Aurora, Ohio 44202, USA<br>Telephone: 330-562-1000; Fax: 330-562-1422. | | 6. Performance Standard: | No applicable performance standards have been<br>issued under Section 514 of the Food, Drug and<br>Cosmetic Act. | | 7. Intended Use: | The Champion 5000 Peripheral Vascular Coil is a<br>multi-element phased array RF coil, used for<br>obtaining diagnostic images of the vasculature and<br>soft tissue anatomy extending from the torso to the<br>foot region, in Magnetic Resonance Imaging<br>Systems. The Champion 5000 Peripheral Vascular<br>Coil is designed for use with the Altaire 0.7T MRI<br>system manufactured by Hitachi Medical Systems<br>America, Inc. The indications for use are the same<br>as for standard MR Imaging. | | 8. Device Description: | The Champion 5000 Peripheral Vascular Coil is a<br>multi-element phased array receive-only coil. The<br>coil consists of five sections: a main coil base, three<br>removable top part sections, and a removable foot<br>section. The open, patient friendly design minimizes<br>claustrophobic effects and maximizes patient<br>comfort. The coil elements and accessory<br>electronics are enclosed in a rigid plastic housing,<br>which is fire rated and has a high impact and tensile<br>strength. | {1}------------------------------------------------ ### 9. Safety and Effectiveness | Peripheral Vascular Coil | Comparison to predicate device or other 510(k) cleared products | |---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------|--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Intended Use: Imaging of the vasculature and soft tissue anatomy extending from the torso to the foot region | -Similar to the Flow 7000 Peripheral Vascular Coil manufactured by USA Instruments, Inc. (K982339) | | Indications for Use: Identical to routine MRI imaging. | -Similar to the Flow 7000 Peripheral Vascular Coil manufactured by USA Instruments, Inc. (K982339) | | Coil Enclosure Material:<br>Flame Retardant Polycarbonate | -Similar to the Profile 7000 Quadrature Volume Neck Coil manufactured by USA Instruments, Inc. (K964531) | | Flame Retardant Polyurethane<br>(TD-27702, Polyone U2773 Neutral) | -Similar to the Magna 5000 Phased Array CTL Spine Coil manufactured by USA Instruments, Inc. (K000002). | | Coil Design: Receive-only phased array coil. | -Similar to the Magna 5000 Phased Array CTL Spine Coil manufactured by USA Instruments, Inc. (K000002). -Similar to the Interventional Body Coil manufactured by USA Instruments, Inc. (K000437) | | Decoupling: Switching diode decoupling. | -Similar to the Magna 5000 Phased Array CTL Spine Coil manufactured by USA Instruments, Inc. (K000002). -Similar to the Interventional Body Coil manufactured by USA Instruments, Inc. (K000437) | | Prevention of RF Burns: Does not transmit RF power; decoupling isolates the coil elements from RF fields during RF transmission; coil elements and circuitry are enclosed in a non- conductive housing. | -Similar to the Flow 7000 Peripheral Vascular Coil manufactured by USA Instruments, Inc. (K982339) | | Radio Frequency Absorption: Coil is a receive only coil and does not transmit RF power. | -Similar to the Magna 5000 Phased Array CTL Spine Coil manufactured by USA Instruments, Inc. (K000002). -Similar to the Interventional Body Coil manufactured by USA Instruments, Inc. (K000437) | | Formation of Resonant Loop:<br>Decoupling isolates the coil elements from RF fields during RF transmission; length of cable and stiffness does not permit looping. | -Similar to the Flow 7000 Peripheral Vascular Coil manufactured by USA Instruments, Inc. (K982339) | : : 、 . {2}------------------------------------------------ #### DEPARTMENT OF HEALTH & HUMAN SERVICES Image /page/2/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with three stripes forming its body and wing. The eagle is facing to the right. The text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" is arranged in a circular fashion around the eagle. #### Public Health Service Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 Ms. Christie Shumaker Manager, QA and Regulatory Affairs USA Instruments, Inc. . 1515 Danner Drive AURORA OH 44202 Re: K023247 Trade/Device Name: Champion 5000 Perpheral Vascular Coil Regulation Number: 21 CFR 892.1000 Regulation Name: Magnetic resonance diagnostic device Regulatory Class: II Product Code: 90 MOS Dated: August 2, 2002 Received: September 30, 2002 Dear Ms. Schumaker: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807): labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (sections 531-542 of the Act); 21 CFR 1000-1050. {3}------------------------------------------------ This letter will allow you to begin marketing your device as described in your 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at one of the following numbers, based on the regulation number at the top of this letter: | 8xx.1xxx | (301) 594-4591 | |----------------------------------|----------------| | 876.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4616 | | 884.2xxx, 3xxx, 4xxx, 5xxx, 6xxx | (301) 594-4616 | | 892.2xxx, 3xxx, 4xxx, 5xxx | (301) 594-4654 | | Other | (301) 594-4692 | Additionally, for questions on the promotion and advertising of your device, please contact the Office of Compliance at (301) 594-4639. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). Other general information on your responsibilities under the Act may be obtained from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html. Sincerely yours, Henry C. Brogdon Nancy C. Brogdon Director, Division of Reproductive, Abdominal, and Radiological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {4}------------------------------------------------ # 510(k) Number (if known);__Ko2 32 47 Device Name: Champion 5000 Peripheral Vascular Coil Indications for Use: The Champion 5000 Peripheral Vascular Coil is designed to provide Magnetic Resonance Images of the vasculature and soft tissue anatomy, extending from the torso to the foot region. Champion 5000 Peripheral Vascular Coil is designed for use with the Hitachi Altaire 0.7T scanner manufactured by Hitachi Medical Systems America, Inc. > Anatomic Regions: vasculature and soft tissue anatomy, extending from the torso to the foot region. Nuclei Excited: Hydrogen The indications for use are the same as for standard imaging: The 1.5T MRI system is indicated for use as an NMR device that produces images that: (1) correspond to the distribution of protons exhibiting NMR signal, (2) depend upon NMR parameters (proton density, spin lattice relaxation time T1, spin-spin relaxation time T2) and (3) display the soft tissue structure of the head and whole body. When interpreted by a trained physician, these images vield information that can be useful in the determination of a diagnosis. (PLEASE DO NOT WRITE BELOW THIS LINE- CONTINUE ON ANOTHER PAGE IF NEEDED) Concurrence of CDRH, Office of Device Evaluation (ODE) Prescription Use (Per 21 CFR 801.109) OR Over-The-Counter Use (Optional Format 1-2-96) Eurid A. Shepman (Division Sign-Off) Division of Reproductive, Abdominal, and Radiological Devices 510(k) Number _
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...