Last synced on 25 January 2026 at 3:41 am

Electromagnetic Stimulator, Pain Relief

Page Type
Product Code
Definition
Intended to apply a magnetic-field induced electrical current to treat pain.
Physical State
The device comes in a variety of shapes and sizes. It generally includes a magnetic stimulator, a stimulation coil, a cooling system, and other accessories.
Technical Method
This device uses a magnetic coil to produce a time-varying magnetic field, which induces a secondary electric field in the targeted tissues which, in turn, non-invasively stimulates peripheral nerves and provides chronic nerve pain relief.
Target Area
This device generally targets peripheral nerves in lower and/or upper extremities and low back.
Regulation Medical Specialty
Neurology
Review Panel
Physical Medicine
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
882.5890
GMP Exempt?
No
Summary Malfunction Reporting
Ineligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 882.5890 Transcutaneous electrical nerve stimulator for pain relief

§ 882.5890 Transcutaneous electrical nerve stimulator for pain relief.

(a) Identification. A transcutaneous electrical nerve stimulator for pain relief is a device used to apply an electrical current to electrodes on a patient's skin to treat pain.

(b) Classification. Class II (performance standards).

Electromagnetic Stimulator, Pain Relief

Page Type
Product Code
Definition
Intended to apply a magnetic-field induced electrical current to treat pain.
Physical State
The device comes in a variety of shapes and sizes. It generally includes a magnetic stimulator, a stimulation coil, a cooling system, and other accessories.
Technical Method
This device uses a magnetic coil to produce a time-varying magnetic field, which induces a secondary electric field in the targeted tissues which, in turn, non-invasively stimulates peripheral nerves and provides chronic nerve pain relief.
Target Area
This device generally targets peripheral nerves in lower and/or upper extremities and low back.
Regulation Medical Specialty
Neurology
Review Panel
Physical Medicine
Submission Type
510(K)
Device Classification
Class 2
Regulation Number
882.5890
GMP Exempt?
No
Summary Malfunction Reporting
Ineligible
Implanted Device
No
Life-Sustain/Support Device
No
Third Party Review
Not Third Party Eligible

CFR § 882.5890 Transcutaneous electrical nerve stimulator for pain relief

§ 882.5890 Transcutaneous electrical nerve stimulator for pain relief.

(a) Identification. A transcutaneous electrical nerve stimulator for pain relief is a device used to apply an electrical current to electrodes on a patient's skin to treat pain.

(b) Classification. Class II (performance standards).