FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
CFR Sub-Part
Subpart D—Physical Medicine Prosthetic Devices
CFR Sub-Part
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
MOC
Cushion, Flotation, Therapeutic
2
Product Code
IMG
Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat
2
Product Code
IMI
Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat
2
Product Code
IMJ
Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat
2
Product Code
QOL
Electroencephalography (Eeg)-Driven Upper Extremity Powered Exerciser
2
Product Code
QRA
Virtual Reality Behavioral Therapy Device For Pain Relief
2
Product Code
BXB
Exerciser, Powered
1
Product Code
EGJ
Device, Iontophoresis, Other Uses
2
Product Code
HPH
Diathermy, Microwave, For Use Other Than Applying Therapeutic Deep Heat
3
Product Code
IKW
Utensil, Homemaking
1
Product Code
IKX
Aid, Transfer
1
Product Code
IKZ
Bed, Patient Rotation, Powered
2
Product Code
ILC
Utensil, Eating
1
Product Code
ILD
Adaptor, Dressing
1
Product Code
ILJ
Bath, Hydro-Massage
2
Product Code
ILK
Transport, Patient, Powered
2
Product Code
ILM
Bath, Sitz, Powered
2
Product Code
ILO
Pack, Hot Or Cold, Water Circulating
2
Product Code
ILS
Adaptor, Hygiene
1
Product Code
ILT
Adaptor, Recreational
1
Product Code
ILW
Adaptor, Grooming
1
Product Code
ILX
Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat
2
Product Code
ILY
Lamp, Infrared, Therapeutic Heating
2
Product Code
ILZ
Accessories, Traction
1
Product Code
IMA
Pack, Heat, Moist
1
Product Code
IMB
Cabinet, Moist Steam
2
Product Code
IMC
Bath, Paraffin
2
Product Code
IMD
Pack, Hot Or Cold, Disposable
1
Product Code
IME
Pack, Hot Or Cold, Reusable
1
Product Code
IMF
Unit, Chilling
1
Product Code
INX
Bed, Air Fluidized
2
Product Code
INY
Bed, Patient Rotation, Manual
1
Product Code
IOA
Diathermy, Microwave, For Use In Applying Therapeutic Deep Heat
2
Product Code
IOB
Lamp, Infrared, Non Heating
2
Product Code
IOD
Components, Exercise
1
Product Code
IOE
Bars, Parallel, Exercise
1
Product Code
IOG
Treadmill, Mechanical
1
Product Code
IOL
Treadmill, Powered
1
Product Code
ION
Exerciser, Non-Measuring
1
Product Code
IOQ
Bed, Flotation Therapy, Powered
2
Product Code
IPF
Stimulator, Muscle, Powered
2
Product Code
K
24
1488
TrainFES Advance
2
Cleared 510(K)
K
24
0348
Quantum Mitohormesis (QMT) (M2101)
2
Cleared 510(K)
K
24
0992
eMVFit (MVF-10M)
2
Cleared 510(K)
K
24
0234
BTL-899MS
2
Cleared 510(K)
K
23
3098
MYOTouch Muscle Stimulator
2
Cleared 510(K)
K
23
2786
Stimulation System (PA series, PR series, S series and Q series)
2
Cleared 510(K)
K
23
3926
accufit
2
Cleared 510(K)
K
23
3485
M-Wave
2
Cleared 510(K)
K
23
2937
BTL-899M
2
Cleared 510(K)
K
23
0701
Stim2Go
2
Cleared 510(K)
K
23
1440
Combo Electrotherapy Device
2
Cleared 510(K)
K
22
3027
NeuroTrigger Basic (NTB)
2
Cleared 510(K)
K
22
3802
accufit
2
Cleared 510(K)
K
22
1274
StarFormer, TightWave
2
Cleared 510(K)
K
23
0167
BACK 4
2
Cleared 510(K)
K
23
2334
DEKA SIMON
2
Cleared 510(K)
K
21
3655
HiTop® (Models: HiToP®4touch, HiToP®2touch, HiToP®1touch)
2
Cleared 510(K)
K
22
2201
Biological Feedback and Stimulation System
2
Cleared 510(K)
K
22
1958
Flex-MI
2
Cleared 510(K)
K
22
0994
Shoulder PacemakerTM
2
Cleared 510(K)
K
21
3197
MyOnyx System
2
Cleared 510(K)
K
22
0738
Motive Knee Wrap
2
Cleared 510(K)
K
22
0327
geko W-3
2
Cleared 510(K)
K
21
3043
Levator Elite (Model LE9011)
2
Cleared 510(K)
K
21
2832
TimeWaver Frequency
2
Cleared 510(K)
K
21
2762
geko W-2
2
Cleared 510(K)
K
19
2746
MyoWorx TM20
2
Cleared 510(K)
K
21
0002
STELLA BIO
2
Cleared 510(K)
K
21
0674
Shoulder Pacemaker
2
Cleared 510(K)
K
21
0938
PowerDot PD-01MT2 Muscle Stimulator
2
Cleared 510(K)
K
21
1094
Nerve and Muscle Stimulator
2
Cleared 510(K)
K
21
0604
Intellihab System
2
Cleared 510(K)
K
21
0979
Prelivia
2
Cleared 510(K)
K
21
0572
Neurodyn V2.0, Neurodyn Aussie V2.0
2
Cleared 510(K)
K
20
2031
Talent-Pro Electromagnetic Stimulator
2
Cleared 510(K)
K
20
3710
Storz Medical MAGNETOLITH Muscle Stimulator
2
Cleared 510(K)
K
20
1285
InMode Evolve System with the Tone Applicator
2
Cleared 510(K)
K
21
0269
PowerDot PD-01MT2 Muscle Stimulator
2
Cleared 510(K)
K
20
3488
emField
2
Cleared 510(K)
K
20
2648
Biofeedback Nerve and Muscle Stimulator
2
Cleared 510(K)
K
20
2079
Physiq
2
Cleared 510(K)
K
20
2490
Avid CT2
2
Cleared 510(K)
K
20
0088
g.Estim FES
2
Cleared 510(K)
K
20
1290
Medline DeNovo 4Pro Electrical Stimulation Device
2
Cleared 510(K)
K
20
1958
ETD Family of Electrotherapy Devices
2
Cleared 510(K)
K
19
3275
Nerve and Muscle Stimulator
2
Cleared 510(K)
K
19
3045
geko™ W-2
2
Cleared 510(K)
K
18
3074
TENS and EMS Stimulator, TENS Stimulator
2
Cleared 510(K)
K
19
2733
RelieforMe TENS/EMS Device Model UPK-GE01
2
Cleared 510(K)
K
19
2249
InMode System with Tone Applicator
2
Cleared 510(K)
K
19
1113
geko T-2 and geko T-3 Neuromuscular Stimulators
2
Cleared 510(K)
K
18
2163
Shear Stress Therapeutics SST 3000
2
Cleared 510(K)
K
18
1759
PowerDot PD-01MT
2
Cleared 510(K)
K
18
1688
R-C1 TENS and EMS Stimulator; R-E1- EMS Stimulator; R-T1 TENS Stimulator
2
Cleared 510(K)
K
18
1059
geko T-3 Neuromuscular Stimulator
2
Cleared 510(K)
K
17
2381
Digitimer DS7AP Constant Current Stimulator
2
Cleared 510(K)
K
18
0082
geko T-2 and geko Plus R-2
2
Cleared 510(K)
K
17
1978
Combo Stimulator MT9000, Combo Stimulator LT7102, TENS Stimulator InTENSity 10
2
Cleared 510(K)
K
17
1071
StimSox(TM) System
2
Cleared 510(K)
K
17
1387
EMS100 Tri-Wave Combination Stimulator
2
Cleared 510(K)
K
16
3125
geko™ T-2 and geko™ Plus R-2 Neuromuscular Stimulators
2
Cleared 510(K)
K
16
2987
FA100 SCCD (Sequential Continuous Contraction Device)
2
Cleared 510(K)
K
16
0614
Xcite Clinical Station
2
Cleared 510(K)
K
16
3067
CyMedica e-vive™ System; CY-1000
2
Cleared 510(K)
K
16
0992
HPM-6000
2
Cleared 510(K)
K
15
1922
StimSox(TM) System
2
Cleared 510(K)
K
15
3696
Chattanooga Revolution Wireless
2
Cleared 510(K)
K
16
0299
geko(TM) Plus R-2 Neuromuscular Stimulator
2
Cleared 510(K)
K
15
3224
VitalStim(R) Plus Electrotherapy System
2
Cleared 510(K)
K
15
2677
geko T-2 Neuromuscular Stimulator
2
Cleared 510(K)
K
15
0742
Muscle Stimulation System 110
2
Cleared 510(K)
K
15
0413
QB1 System Powered Muscle Stimulator & Transcutaneous Electrical Nerve Stimulator
2
Cleared 510(K)
K
14
0467
FLEX-MT +
2
Cleared 510(K)
K
13
3638
GEKO
2
Cleared 510(K)
K
13
1917
NEURODYN COMPACT, NEURODYN II
2
Cleared 510(K)
K
13
2284
VECTRA NEO CLINICAL THERAPY SYSTEM
2
Cleared 510(K)
K
13
0691
ELECTROTHERAPY DEVICE (COMBO UNIT)
2
Cleared 510(K)
K
13
0052
TONE-A-MATIC
2
Cleared 510(K)
K
13
1629
NEURODYN MULTIWAVE, AUSSIE SPORT
2
Cleared 510(K)
K
13
1222
AMPCARE ESP THERAPY SYSTEM
2
Cleared 510(K)
K
13
2137
MULTISTIM
2
Cleared 510(K)
K
13
0424
STIMEL-03
2
Cleared 510(K)
K
12
3354
REVITIVE IX
2
Cleared 510(K)
K
12
4016
EMPI PHOENIX
2
Cleared 510(K)
K
12
3642
MUSCLE STIMULATION SYSTEM
2
Cleared 510(K)
K
12
0922
GUARDIAN DYSPHAGIA DUAL CHANNEL NMES UNIT
2
Cleared 510(K)
K
11
3010
FDES100(TENS AND EMS STIMULATOR, FDES102(ED402) TENS STIMULATOR
2
Cleared 510(K)
K
11
3017
SYS*STIM 240
2
Cleared 510(K)
K
11
2148
POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
11
2348
RS-4I MUSCLE STIMULATOR
2
Cleared 510(K)
K
11
1279
NEXWAVE COMBO MUSCLE STIMULATOR SYSTEM
2
Cleared 510(K)
K
10
3738
H-WAVE
2
Cleared 510(K)
K
10
0862
BODYFLOW P2CH
2
Cleared 510(K)
K
09
2202
ESWALLOW DYSPHAGIA THERAPY KIT, PMI DYSPHAGIA THERAPY KIT
2
Cleared 510(K)
K
10
2202
GS 3000
2
Cleared 510(K)
K
09
3324
EMPI CONTINUUM
2
Cleared 510(K)
K
09
3138
MT9000 SERIES ELECTRO-STIMULATOR, MODELS MT9000, MT9002, MT9001, MT9004 AND MT9003
2
Cleared 510(K)
K
10
0117
LT3000 COMBO STIMULATOR, LT3001 TENS STIMULATORY, LT3002 EMS STIMULATOR
2
Cleared 510(K)
K
09
2791
KNEEHAB XP CONTROLLER, MODEL 411
2
Cleared 510(K)
K
09
3259
ARP RX100
2
Cleared 510(K)
K
09
1248
MAXEMS, MODELS 1000 AND 2000
2
Cleared 510(K)
K
09
0532
T.E.A.R. TECH3
2
Cleared 510(K)
K
08
3105
KNEEHAB XP CONDUCTIVE GARMENT, TYPE 411
2
Cleared 510(K)
K
09
0632
COMPEX REHAB
2
Cleared 510(K)
K
08
0950
STIWELL MED4
2
Cleared 510(K)
K
07
1677
SRT II MUSCLE STIMULATOR
2
Cleared 510(K)
K
07
0888
COMBI 8 MAX
2
Cleared 510(K)
K
08
0787
BIOMOVE 5000 SYSTEM
2
Cleared 510(K)
K
08
0661
MODELS TENS 7000, EMS 7500 AND TWIN STIM
2
Cleared 510(K)
K
07
3361
MUSCLE PAIN DEVICE (MPD)
2
Cleared 510(K)
K
07
2252
VEINOPLUS NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
06
3642
FD EMS, MODEL # D-FJ30E
2
Cleared 510(K)
K
07
1093
SAN SHIH POWERED MUSCLE STIMULATOR, MODEL 202
2
Cleared 510(K)
K
07
2795
MODELS EMS 5.0, EMS 5.1
2
Cleared 510(K)
K
07
1431
GLOBUS GENESY 1100 STIMULATOR
2
Cleared 510(K)
K
07
1320
EVERLIFE POWERED MUSCLE STIMULATOR, MODEL E-100204, E-100504, E-100509, E-100804, E-201111, E-201211, E-201311
2
Cleared 510(K)
K
07
0425
VITALSTIM EXPERIA
2
Cleared 510(K)
K
06
2453
KINGLY STAR POWERED MUSCLE STIMULATOR, MODEL KS-138
2
Cleared 510(K)
K
06
2354
VECTRA GENISYS VMS FR
2
Cleared 510(K)
K
05
3285
MAGBODY DT-1200, DT-1200T, DT-1200M, DT-1200PT, DT-1200PM
2
Cleared 510(K)
K
05
3266
MYOTRAC INFINITI
2
Cleared 510(K)
K
05
0921
EASYSTIM NMS-28
2
Cleared 510(K)
K
05
1135
AXIOM NVP8500
2
Cleared 510(K)
K
05
0687
AXIOM EPS8000
2
Cleared 510(K)
K
05
0847
IF TRUE SINE INTERFERENTIAL STIMULATOR, MODEL WL-2206A
2
Cleared 510(K)
K
05
0595
FT2000 SEQUENCER FOR MUSCLE STIMULATOR
2
Cleared 510(K)
K
05
0046
REHABILICARE IF 3 WAVE INTERFERENTIAL STIMULATOR SYSTEM, MODEL 7110S
2
Cleared 510(K)
K
02
4258
NEUROTECH KNEEHAB
2
Cleared 510(K)
K
04
1390
DIAMOND MEDISTIM
2
Cleared 510(K)
K
04
2650
BIOMOVE 3000
2
Cleared 510(K)
K
04
1920
INFINITY PLUS ELECTROTHERAPY SYSTEM
2
Cleared 510(K)
K
04
1063
SMARTWAVE MS 2000
2
Cleared 510(K)
K
04
2881
PMD-2000 INTERFERENTIAL STIMULATOR
2
Cleared 510(K)
K
03
4005
SDS-4I
2
Cleared 510(K)
K
04
0849
MENTAMOVE
2
Cleared 510(K)
K
03
2954
ELPHA, MODELS II 500, II 1000, II 2000, II 3000 AND E80
2
Cleared 510(K)
K
03
3174
BMLS03-3
2
Cleared 510(K)
K
04
1146
CONTROL SOLUTIONS, INC., MODEL CS3102 HVG
2
Cleared 510(K)
K
03
1310
TAI SHENG VARIOUS NEOX POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
04
0306
HIGH VOLTAGE PULSED STIMULATOR, MODEL BMLS02-7
2
Cleared 510(K)
K
03
2955
AUTOMOVE, MODEL AM800
2
Cleared 510(K)
K
03
3544
ELECTRICAL MUSCLE STIMULATOR, MODELS N605 AND N607
2
Cleared 510(K)
K
03
1375
BESMED VARIOUS MODELS OF POWERED MUSCLE STIMULATOR, BE-560/BE-580
2
Cleared 510(K)
K
03
1820
ELECTRONIC MUSCLE MASSAGE, MODELS BE-550 AND BE-660
2
Cleared 510(K)
K
03
3140
NEUROMUSCULAR ELECTRICAL STIMULATOR, MODEL EV-807P
2
Cleared 510(K)
K
02
3000
HOME CARE VARIOUS MODELS OF POWERED MUSCLE STIMULATOR, HT-329M SERIES
2
Cleared 510(K)
K
03
2941
AUTOSOUND 7.6 MUSCLE STIMULATOR, TENS, THERAPEUTIC ULTRASOUND AND COMBINATION DEVICE
2
Cleared 510(K)
K
03
2178
RHYTHM TOUCH Q 2-WAY
2
Cleared 510(K)
K
03
0998
MEDRELIEF SE SERIES, MODELS SE-50, SE-100, SE-200, SE-300
2
Cleared 510(K)
K
03
2652
RS-4I MUSCLE STIMULATOR FAMILY
2
Cleared 510(K)
K
03
1427
ELECTRO NEUROMUSCULAR STIMULATOR, MODEL BMLS03-1
2
Cleared 510(K)
K
03
0403
CEFAR REHAB 2 AND REHAB 2 PRO
2
Cleared 510(K)
K
02
0478
ELECTROMEDICARIN 900
2
Cleared 510(K)
K
03
1884
INTERFERENTIAL STIMULATOR, MODEL NETWAVE
2
Cleared 510(K)
K
02
4181
PRIZM MEDICAL, INC. MICRO-Z STIMULATION SYSTEM
2
Cleared 510(K)
K
02
3036
CARE ETS
2
Cleared 510(K)
K
03
1017
SYS*STIM 208 AND 208A
2
Cleared 510(K)
K
03
0507
T.E.A.R. TECH3 MODEL #44TT03
2
Cleared 510(K)
K
02
2998
HOME CARE VAREIOUS MODELS OF POWERED MUSCLE STIMULATOR, HT-311, HT-311N, HT-312
2
Cleared 510(K)
K
02
3230
ECHOPULSE MUSCLE STIMULATOR SYSTEM, MODEL 800
2
Cleared 510(K)
K
02
3001
HOME CARE VARIOUS MODELS OF POWERED MUSCLE STIMULATOR, HT-326L
2
Cleared 510(K)
K
03
0648
VECTORSURGE 5 MODEL 470
2
Cleared 510(K)
K
02
3997
TENSCARE ULTIMA NMS/EMS
2
Cleared 510(K)
K
03
0254
INTERFERENTIAL STIMULATOR, MODEL RTM1000
2
Cleared 510(K)
K
02
1588
ELECTRO NEUROMUSCULAR STIMULATOR, MODEL BMLS02-5
2
Cleared 510(K)
K
02
3439
MEDS-4 NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
02
3446
MEDS-3 NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
02
4036
PRODUCT LINE-COMBO STIMULATOR/SEQUENTIAL STIMULATOR, MODEL IF-5000
2
Cleared 510(K)
K
02
3347
VITAL STIM
2
Cleared 510(K)
K
02
0130
ROLOR POWERED MUSCLE STIMULATOR, MODEL GP-8016M
2
Cleared 510(K)
K
02
0750
DIGITAL ELECTRICAL MUSCLE STIMULATOR, MODEL EV-807 DIGITAL EMS
2
Cleared 510(K)
K
02
2493
EMS 400
2
Cleared 510(K)
K
02
2776
NESS SYSTEM
2
Cleared 510(K)
K
02
2175
P4 PHYSIO
2
Cleared 510(K)
K
02
1905
CLASSIC NMS
2
Cleared 510(K)
K
02
1472
HMS-DHR-3 NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
01
4019
NEUROTECH MEDISTIM PLUS, TYPE 291
2
Cleared 510(K)
K
01
3768
POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
02
1754
APEX MEDICAL DIGITAL EMS TS1311, TS1312
2
Cleared 510(K)
K
02
1100
300 PV COMPLETE ELECTROTHERAPY SYSTEM
2
Cleared 510(K)
K
02
1763
RS2MI MUSCLE STIMULATOR FAMILY
2
Cleared 510(K)
K
02
0637
SELECT STIM
2
Cleared 510(K)
K
02
0684
FINESUN EMS STIMULATOR
2
Cleared 510(K)
K
02
0314
DIGI-PRO TENS, MODEL WL-2204 AND WL-2205
2
Cleared 510(K)
K
01
1588
SURETONE
2
Cleared 510(K)
K
01
3770
MODIFICATION TO: WINNER ST-2 STIMULATOR
2
Cleared 510(K)
K
01
3771
MODIFICATION TO: WINNER CM-2 MUSCLE STIMULATOR, TENS, THERAPEUTIC ULTRASOUND AND COMBINATION DEVICE
2
Cleared 510(K)
K
99
2099
BIO SPA INTELLIGENT
2
Cleared 510(K)
K
01
3081
MEDSTAR 150
2
Cleared 510(K)
K
01
2885
NEUROMOVE NM900
2
Cleared 510(K)
K
01
1913
SUN-TENS PALM TYPE R5/COMPACT WIRELES M2 EMS SERIES
2
Cleared 510(K)
K
00
0741
EMS JUMPER II DUAL CHANNEL NEUROMUSCULAR STIMULATOR SYSTEM, MODEL E-188
2
Cleared 510(K)
K
01
0749
ELECTRO NEUROMUSCULAR STIMULATOR, MODEL NMS-DIGITAL
2
Cleared 510(K)
K
00
2339
AEMS V, EMS-1000, MODEL TS-140500 AND AEMS VI, EMS-1000 PLUS, MODEL TS-140600
2
Cleared 510(K)
K
01
0807
MUSCLE STIMULATOR SA-100
2
Cleared 510(K)
K
00
2336
MS104A, NEWMINI II (EMS-II), MODEL AP-101050T AND MEDTRIM (EMS-V), MODEL AP-102050T
2
Cleared 510(K)
K
01
0745
EMS 3000
2
Cleared 510(K)
K
00
3433
NEURO-TRAIN III (3)
2
Cleared 510(K)
K
00
3596
SMITH & NEPHEW RESTIM
2
Cleared 510(K)
K
00
2410
FREED BIOELECTRIC: DYSPHAGIA TREATMENT DEVICE
2
Cleared 510(K)
K
00
2058
VECTORSURGE 5, MODEL VS-500
2
Cleared 510(K)
K
01
0665
TRANSAMERICA DIGITAL EMS
2
Cleared 510(K)
K
00
3260
VECTORSURGE 4 INTERFERENTIAL THERAPY UNIT MODEL VS 460
2
Cleared 510(K)
K
00
0808
RICH-MAR WINNER ST4 MUSCLE STIMULATOR, INTERFERENTIAL, AND TENS DEVICE
2
Cleared 510(K)
K
00
0114
RS-4M+MUSCLE STIMULATOR
2
Cleared 510(K)
K
99
3420
CONTROL SOLUTIONS INC, MODEL CS3101
2
Cleared 510(K)
K
99
4062
HMS NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
99
4065
MS-ONE, MODEL MS-1
2
Cleared 510(K)
K
99
3821
VECTORSURGE 4 INTERFERENTIAL THERAPY UNIT
2
Cleared 510(K)
K
99
1241
IF8000
2
Cleared 510(K)
K
99
0787
TRIO 300
2
Cleared 510(K)
K
99
0697
RS-4V MUSCLE STIMULATOR
2
Cleared 510(K)
K
98
4142
SONICATOR PLUS 992, MODEL NUMBER ME 992 AND SONICATOR PLUS 994, MODEL NUMBER ME 994
2
Cleared 510(K)
K
98
4114
SYS STIM 294, MODEL ME 294
2
Cleared 510(K)
K
98
4113
MS400
2
Cleared 510(K)
K
98
4021
MS300
2
Cleared 510(K)
K
98
2828
FORTE, MODELS CPS 400 STIM, CPS 200 STIM
2
Cleared 510(K)
K
98
2482
HANDMASTER NMS1
2
Cleared 510(K)
K
98
2388
SURGI STIM
2
Cleared 510(K)
K
98
0158
MYO-TRAIN V (5)
2
Cleared 510(K)
K
98
0040
ELECTRONIC MUSCLE STIMULATOR - MICROSTIM J-1304D
2
Cleared 510(K)
K
97
3929
NEOTONUS MS-101 MAGNETIC MUSCLE STIMULATOR SYSTEM
2
Cleared 510(K)
K
98
0958
HAKOMED ELECDT/VACUPULLS
2
Cleared 510(K)
K
98
0892
HAKOMED ELECDT / PRO ELEDT SERIES
2
Cleared 510(K)
K
98
0346
ELECTRICAL MUSCLE STIMULATOR DEVICE ( PGS-4000)
2
Cleared 510(K)
K
98
0448
MODEL PS-1 PENA MUSCLE STIMULATOR
2
Cleared 510(K)
K
97
3223
STELLAR MODEL HS-04
2
Cleared 510(K)
K
97
2997
AM800 AUTOMOVE EMG TRIGGERED ELECTRICAL MUSCLE STIMULATION
2
Cleared 510(K)
K
96
4434
SD-970EMS ELECTRICAL MUSCULAR STIMULATOR
2
Cleared 510(K)
K
96
1751
W.M.E. GPS 1001
2
Cleared 510(K)
K
97
0847
IMPULSE HVG
2
Cleared 510(K)
K
97
2055
MSI MAGNA-STYM
2
Cleared 510(K)
K
97
1542
ORTHO DX NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
95
5666
EGS4000
2
Cleared 510(K)
K
97
0155
NEURO-TRAIN II (2)
2
Cleared 510(K)
K
96
4028
SYS STIM 226
2
Cleared 510(K)
K
96
4423
AXIOM INF
2
Cleared 510(K)
K
95
0550
XH-1 NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
96
2462
MUSCLEMAX PLUS ELECTRICAL MUSCLE STIMULATOR
2
Cleared 510(K)
K
96
0457
ELECTRONIC MUSCLE STIMULATOR MODEL EMS-1C/EMS-2C
2
Cleared 510(K)
K
95
2273
HANDMASTER NMS1
2
Cleared 510(K)
K
95
5736
STIM-8
2
Cleared 510(K)
K
96
0433
VST-10, VST-10/2
2
Cleared 510(K)
K
95
5146
AXIOM-HVG
2
Cleared 510(K)
K
96
0489
ULTRA IV
2
Cleared 510(K)
K
96
0096
ULTRA III
2
Cleared 510(K)
K
95
4411
GALVA-5-M
2
Cleared 510(K)
K
95
1682
OCTOSTIM
2
Cleared 510(K)
K
95
2680
VARAPULSE-2
2
Cleared 510(K)
K
95
3136
RS-4M
2
Cleared 510(K)
K
95
1727
Z-WATCH SYSTEM
2
Cleared 510(K)
K
95
3615
FORTE ES-400
2
Cleared 510(K)
K
95
0783
4000+
2
Cleared 510(K)
K
94
3007
ITP-HVPC GALVANIC STIMULATOR
2
Cleared 510(K)
K
95
0617
SMART WAVE GS100
2
Cleared 510(K)
K
94
6186
CHAL-2500
2
Cleared 510(K)
K
94
3185
BX-200 SC
2
Cleared 510(K)
K
94
2195
BX-400S
2
Cleared 510(K)
K
94
4935
DYNATRON 250
2
Cleared 510(K)
K
94
6298
BIOSTIM-HV
2
Cleared 510(K)
K
93
2075
MASTERSTIM 1-4
2
Cleared 510(K)
K
94
5510
FX-4 NMS (4CHANNEL TABLE MODEL)
2
Cleared 510(K)
K
94
5509
FX-2 NMS (2CHANNEL TABLE MODEL)
2
Cleared 510(K)
K
94
5508
FX-2P NMS (2 CHANNEL PORTABLE)
2
Cleared 510(K)
K
94
0301
COMPEX 2
2
Cleared 510(K)
K
93
4556
EMS-250
2
Cleared 510(K)
K
93
3194
THE SIGNATURE SERIES, IMC IV
2
Cleared 510(K)
K
93
3196
THE SIGNATURE SERIES, IC II
2
Cleared 510(K)
K
94
1049
MUSCLEMAX ELECTRICAL MUSCLE STIMULATOR
2
Cleared 510(K)
K
93
4919
THE SIGNATURE SERIES, MAGNUM 100
2
Cleared 510(K)
K
94
0349
NEUROMUSCULAR ELECTRICAL STIMULATOR
2
Cleared 510(K)
K
93
3653
MS 2500
2
Cleared 510(K)
K
93
1401
EMS
2
Cleared 510(K)
K
93
2898
POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
92
6084
HVGS 9000
2
Cleared 510(K)
K
93
3195
THE SIGNATURE SERIES, IC IV
2
Cleared 510(K)
K
93
2916
GALVANIC GENERATOR MODEL IMF4150/A
2
Cleared 510(K)
K
93
2739
FAST START NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
93
3072
PCI 2500
2
Cleared 510(K)
K
93
3249
DYNATRON 100 PLUS
2
Cleared 510(K)
K
93
3176
NEUROTECH 2000 (NT2000)
2
Cleared 510(K)
K
93
1781
JACE TRI-STIM DEVICE
2
Cleared 510(K)
K
93
2764
THERAPEUTIC STIMULATOR 300(TS-300) & 300P(TS-300P)
2
Cleared 510(K)
K
93
2610
PCI 4000
2
Cleared 510(K)
K
93
2596
NT4-PLUS
2
Cleared 510(K)
K
93
2399
THERAPEUTIC STIM 200 (TS-200)/200P (TS-200P)
2
Cleared 510(K)
K
92
6510
STAODYN EMS+2
2
Cleared 510(K)
K
92
6410
ULTRATONE 8+ & 20
2
Cleared 510(K)
K
92
6265
NEURO-CARE 1000
2
Cleared 510(K)
K
93
0670
PHYACTION 787
2
Cleared 510(K)
K
92
4699
PMP MUSCLE STIMULATOR
2
Cleared 510(K)
K
92
3498
BIPHASIC UNIT
2
Cleared 510(K)
K
92
3501
HIGH VOLT UNIT
2
Cleared 510(K)
K
92
5680
LSI SYSTEM IV INTERFERENTIAL,MUSCLE STIMULATOR
2
Cleared 510(K)
K
92
0389
RS-2 NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
92
0388
RS-1 NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
92
3914
IF-II (TM), MODEL 7200
2
Cleared 510(K)
K
91
2328
ELECTRONIC MUSCLE STIMULATORS, EXCEL II, MODIFIED
2
Cleared 510(K)
K
92
1668
STAODYN TUWAVE
2
Cleared 510(K)
K
92
0532
ACU-TRAIN V (5)
2
Cleared 510(K)
K
91
5321
BTM-200 (PROPOSED) POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
91
2462
Q-MS NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
91
4231
ELPHA 2000
2
Cleared 510(K)
K
92
0833
RICH-MAR HV 1000 MUSCLE STIMULATOR
2
Cleared 510(K)
K
92
0436
MEDTRONIC RESPOND III NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
91
5230
H WAVE MUSCLE STIMULATOR
2
Cleared 510(K)
K
91
4904
THERAPEUTIC STIMULATOR 2100 (TS-2100)
2
Cleared 510(K)
K
91
4999
BTM-100 POWERED MUSCLE STIMULATOR (PROPOSED)
2
Cleared 510(K)
K
90
3870
KINESTHETICS MODEL 2000 NMS
2
Cleared 510(K)
K
90
4509
POWER TRAINER WITH NEUROMUSCULAR STIMULATION
2
Cleared 510(K)
K
91
4539
RICH-MAR IFV 1000
2
Cleared 510(K)
K
90
3148
CHALLENGE 3000 NEUROLOGICAL BOOSTER
2
Cleared 510(K)
K
91
2642
EMS300, EMS400, EMS8000
2
Cleared 510(K)
K
91
2342
DR. LIBERSON'S MICROPULSE NEUROMUSCULAR TRANS STIM
2
Cleared 510(K)
K
91
3444
GLOBALCARE EMS
2
Cleared 510(K)
K
90
4360
CHALLENGE 4010 ONE CHANNEL WIDE PULSE STIMULATOR
2
Cleared 510(K)
K
91
0801
HIGH VOLTAGE PULSED GALVANIC STIMULATION APPLICATI
2
Cleared 510(K)
K
91
3272
EMS/400
2
Cleared 510(K)
K
90
5107
UTS ELECTRICAL MUSCLE STIMULATION DEVICE-PGS 1500
2
Cleared 510(K)
K
90
4332
MSTIM-2000 EMS
2
Cleared 510(K)
K
90
3711
RHEOLOGIC I
2
Cleared 510(K)
K
90
3149
CHANLLENGE 1010 PATIENT KEY PROGRAM STATION
2
Cleared 510(K)
K
90
2255
OMRON PULSE STIMULATOR MODEL HV-F05
2
Cleared 510(K)
K
90
2599
REVISED HIGH VOLTAGE STIMULATOR INTELECT 150
2
Cleared 510(K)
K
90
0647
SOUTHERN CROSS HI-V4 PULSED HIGH VOLTAGE GALVANIC
2
Cleared 510(K)
K
90
2371
HAELAN 340 MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
2513
CHALLENGE 6010 POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
2514
CHALLENGE 5010 POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
2512
CHALLENGE 8000 POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
2511
CHALLENGE 7010 POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
1849
LUMISCOPE EMS 8000
2
Cleared 510(K)
K
89
3980
LINDQUIST MODEL 370
2
Cleared 510(K)
K
89
2960
LINDQUIST MODEL SS POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
1770
CHALLENGE 7000 POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
1769
CHALLENGE 6000 POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
1768
CHALLENGE 5000 POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
1779
RICH-MAR BP-2000 ELECTRICAL MUSCLE STIMULA. UNIT
2
Cleared 510(K)
K
90
1326
CHALLENGE 20 POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
88
1431
SIEMENS STEREODYNATOR 828
2
Cleared 510(K)
K
90
0029
SPECTRASTIM 2000 MUSCLE STIMULATOR
2
Cleared 510(K)
K
90
0823
ISOTRON 220
2
Cleared 510(K)
K
90
0413
INTELECT 775MP POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
89
3220
VERIMED MYOEXORCISER VERISTIM
2
Cleared 510(K)
K
89
6908
EXCEL STIM II
2
Cleared 510(K)
K
89
6836
EXCEL STIM
2
Cleared 510(K)
K
89
5983
MULTISTIM PLUS
2
Cleared 510(K)
K
89
5301
EMS 8100
2
Cleared 510(K)
K
89
1987
BIO-STYM 250 (MUSCLE STIMULATOR)
2
Cleared 510(K)
K
89
5760
ELECTRICAL MUSCLE STIMULATOR--PGS 2000 TENS DEVICE
2
Cleared 510(K)
K
89
3878
SYS*STIM 206A
2
Cleared 510(K)
K
89
3879
SYS*STIM 207A
2
Cleared 510(K)
K
89
3994
IF2000 ELECTRICAL MUSCLE STIMULATOR UNIT
2
Cleared 510(K)
K
89
5671
STIMTRAC II CATALOG NUMBER 78-8500
2
Cleared 510(K)
K
89
3851
THERASTIM
2
Cleared 510(K)
K
88
4651
ELECTRO NEUROMUSCULAR STIMULATOR MODEL 2000
2
Cleared 510(K)
K
89
1458
SW 803 LOW FREQUENCY STIMULATOR DANA TOUCH
2
Cleared 510(K)
K
88
2386
AGAR 3K NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
89
0434
EMS 300 MUSCLE STIMULATORS
2
Cleared 510(K)
K
88
2387
AGAR 4000 NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
88
1777
LIKON
2
Cleared 510(K)
K
89
3964
SPECTRASTIM TM 1000
2
Cleared 510(K)
K
87
5317
ELECTRICAL MUSCLE STIMULATOR MODEL MYOAID
2
Cleared 510(K)
K
88
1196
AM 706 ELECTROMYOGRAPH, STIM., NEURO., EXTERNAL
2
Cleared 510(K)
K
88
4396
MODIFIED THER-A-PULSE UNIT
2
Cleared 510(K)
K
89
0147
RICH-MAR CONDUCTIVE GEL II W/ALOE VERA
2
Cleared 510(K)
K
88
1470
SOKEN PLUS(TM) ELECTRONIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
87
4232
MUSCLE STIM. DEVICES, BM 2000,4000,6000,8000
2
Cleared 510(K)
K
87
4212
VERIMED MYO/PREMS
2
Cleared 510(K)
K
88
0699
ENDOMED CV405
2
Cleared 510(K)
K
88
0948
RICH-MAR G1000 EMS
2
Cleared 510(K)
K
88
1024
ARCHGAUGE(TM)
2
Cleared 510(K)
K
88
0235
INTELECT MODEL 120
2
Cleared 510(K)
K
88
1082
GV 11 (TM), MODEL 9700
2
Cleared 510(K)
K
87
5238
SIEMENS NEUROTON 826 AND 827
2
Cleared 510(K)
K
88
0234
INTELECT VMS 2, OR INTELECT VMS II
2
Cleared 510(K)
K
87
4736
RICH-MAR HV-2000 ELECTRICAL MUSCLE STIMULATOR
2
Cleared 510(K)
K
87
1421
MODEL HL-100 PORTABLE DC ELECT. THERAPEUTIC UNIT
2
Cleared 510(K)
K
87
4076
MODIFIED OMNISTIM(TM) ELECTRICAL MUSCLE STIMULATOR
2
Cleared 510(K)
K
87
3125
SOKEN(TM) ELECTRONIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
87
2606
TELESONIC BODY STIMULATOR
2
Cleared 510(K)
K
87
2970
THER-A-PULSE
2
Cleared 510(K)
K
87
2974
DYNATRAC
2
Cleared 510(K)
K
87
2036
RICH-MAR CONDUCTIVE GEL
2
Cleared 510(K)
K
87
2655
INTELECT 775
2
Cleared 510(K)
K
87
2207
MS-108, POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
87
2206
MD-104, POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
87
2208
MS-112, POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
87
2753
MYOSTIM(TM), MODEL 6600
2
Cleared 510(K)
K
87
2654
INTELECT MODEL 575
2
Cleared 510(K)
K
87
0947
DYNATRON 500
2
Cleared 510(K)
K
87
1472
KINESTIM MUSCLE STIMULATOR
2
Cleared 510(K)
K
87
0515
DYNATRON 438
2
Cleared 510(K)
K
87
0774
TRU-STIM MUSCLE STIMULATOR
2
Cleared 510(K)
K
86
5070
CHIRO-STIM
2
Cleared 510(K)
K
86
5054
STIMUTRON MODEL 100
2
Cleared 510(K)
K
86
4625
MYOPAC (TM), MODEL 9600
2
Cleared 510(K)
K
86
4558
U66 EMS
2
Cleared 510(K)
K
86
4284
MUSCLE MASTER (MEDIUM VOLTAGE STIMULATOR)
2
Cleared 510(K)
K
86
4010
EMPI MODEL 712, LOGIX(TM), NMS
2
Cleared 510(K)
K
86
2685
MUSCLE MASTER (BIPOLAR STIMULATOR)
2
Cleared 510(K)
K
86
2485
MS-179 ELECTRONIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
86
2486
MS-159 ELECTRONIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
86
2487
MS-139 ELECTRONIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
86
2031
HAWKINS MINI-E.B.A.
2
Cleared 510(K)
K
86
1136
INTERSTIM 100 SYSTEM
2
Cleared 510(K)
K
86
1796
FITTRONIC
2
Cleared 510(K)
K
86
0314
NEUROTECH-4 PROGRAM NEUROMUSCULAR STIMULATOR 281
2
Cleared 510(K)
K
86
0315
NEUROTECH-16 PROGRAM SYSTEM CONTROLLER MODEL 280
2
Cleared 510(K)
K
85
4485
RICH-MAR IF 200
2
Cleared 510(K)
K
86
1739
TEC PORTAMAX H.V. PULSED GALVANIC STIMULATOR
2
Cleared 510(K)
K
86
0619
ES 180-DCM MUSCLE STIMULATOR
2
Cleared 510(K)
K
86
0758
VACO SUCTION ELECTRODE UNIT
2
Cleared 510(K)
K
86
0107
SYS*STIM 206 (MODEL-ME 206)
2
Cleared 510(K)
K
85
5249
MIDIFICATION SYS*STIM 207 (MODEL-ME207)
2
Cleared 510(K)
K
85
3154
HV-4
2
Cleared 510(K)
K
85
4801
MS-189 MUSCLE STIMULATOR
2
Cleared 510(K)
K
85
4720
NEMECTRODYN MODEL 2 & ENDOVAC 2 POWER MUSCLE STIM.
2
Cleared 510(K)
K
85
4775
EMPI MODEL 730 NMS
2
Cleared 510(K)
K
85
4774
EMPI MODEL 720 NMS
2
Cleared 510(K)
K
85
3750
SYS*STIM 207 MODEL ME 207
2
Cleared 510(K)
K
85
2077
VERSA STIM 380, MUSCLE STIMULATOR
2
Cleared 510(K)
K
84
4727
MODEL 1000
2
Cleared 510(K)
K
85
1046
MYOCARE PLUS DUAL CHANNEL STIMULATOR
2
Cleared 510(K)
K
85
0850
AUTOMOVE/OMNISTIM IV-ELECTRICAL MUSCLE STIMULATOR
2
Cleared 510(K)
K
84
4126
SONTEC II
2
Cleared 510(K)
K
85
1037
ORTHOTRON MUSCLE STIMULATOR MK II DC
2
Cleared 510(K)
K
85
0698
MEDIUM FREQU. ELEC. MUSCLE STIMULATOR
2
Cleared 510(K)
K
85
0453
SINUS AC-POWERED MUSCLE STIMULATOR
2
Cleared 510(K)
K
84
4387
ESCOTEK-EST 221 VACUUM UNIT
2
Cleared 510(K)
K
84
4390
ESCOTEK-EST 204 MULTI STIM
2
Cleared 510(K)
K
84
4389
ESCOTEK EST 210, HIGH VOLTAGE ELECTRO GALVANIC STI
2
Cleared 510(K)
K
84
4388
ESCOTEK EST 220 INTERFERENCE THERAPY UNIT
2
Cleared 510(K)
K
85
0013
SYS STIM 206(MODEL-ME 206) MUSCLE STIMULATOR
2
Cleared 510(K)
K
85
0047
SANYO ELECTRONIC MUSCLE STIMULATORS
2
Cleared 510(K)
K
84
4617
EXCEL TECH MST-7 ISOELECTRONIC THERAPY DEVICE
2
Cleared 510(K)
K
84
4489
ELECTRONIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
84
4580
MEDCOLATOR MODEL HVX
2
Cleared 510(K)
K
84
4466
THE PROBE 100
2
Cleared 510(K)
K
83
3928
MYOPULSE
2
Cleared 510(K)
K
84
3583
FIRM-A-TRON MARK X
2
Cleared 510(K)
K
84
3638
HEALTH PULSE FA-222 POWER MUSCLE STIMUL
2
Cleared 510(K)
K
84
3488
ELECTROSTIM 380
2
Cleared 510(K)
K
84
2712
MEDCOLATOR MODEL GX
2
Cleared 510(K)
K
84
2803
INTERFERENZ 4
2
Cleared 510(K)
K
84
2804
DIADYN 4
2
Cleared 510(K)
K
84
2268
VACUPULSE VACUUM UNIT
2
Cleared 510(K)
K
84
1647
NEUROMEDICS ULTRASTIM 650-01
2
Cleared 510(K)
K
84
2142
BX-400
2
Cleared 510(K)
K
84
1779
ELECTRONIC MUSCLE EXERCISE EQUIPMENT
2
Cleared 510(K)
K
84
1579
MULTIPLEX I, INTERFERENTIAL CURRENT
2
Cleared 510(K)
K
84
1382
EMPI MODEL 712, LOGIX, NMS
2
Cleared 510(K)
K
84
1278
OMNISTIM III INTERFERENTIAL THERAPY
2
Cleared 510(K)
K
84
0895
ELECTRICAL NEURO-MUSCULAR STIMULATOR
2
Cleared 510(K)
K
84
1112
TTI REHABILATATION GYM SYS
2
Cleared 510(K)
K
84
0724
MUSCLE STIMULATOR X-10
2
Cleared 510(K)
K
84
0467
NEUROMUSCULAR STIMULATOR 3105
2
Cleared 510(K)
K
84
0346
NEUROMUSCLAR II
2
Cleared 510(K)
K
84
0149
BMR POWERSTIM
2
Cleared 510(K)
K
84
0148
BMR-16 CLINIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
84
0147
BMR-2 MUSCLE STIMULATOR
2
Cleared 510(K)
K
83
3945
COSMODYN-S INTERFERENTIAL MUSCLE STIM
2
Cleared 510(K)
K
83
2805
BIONICARE STIMULATOR BIO-1
2
Cleared 510(K)
K
83
4092
MULTIPLE SOKEN 3 ELECTRON-MUSCLE STIM
2
Cleared 510(K)
K
83
3808
NUTRA-TONE 500
2
Cleared 510(K)
K
83
2976
BX-600 EMS
2
Cleared 510(K)
K
83
2988
STAODYN EMS/PLUS
2
Cleared 510(K)
K
83
2546
MARK V HIGH VOLTAGE GALVANIC STIMULATORR
2
Cleared 510(K)
K
83
1473
ULTRA PULSATOR MF
2
Cleared 510(K)
K
83
1003
MEASURE-UP MUSCLE STIMULATOR
2
Cleared 510(K)
K
83
0055
RICH-MAR HV 20
2
Cleared 510(K)
K
82
2924
MINISTIM 180
2
Cleared 510(K)
K
82
3279
RESPOND QUADRIFLEX #3129 SINGLE CHANNEL
2
Cleared 510(K)
K
82
2519
HAWKINS EBA -16 MUSCLE STIMULATOR
2
Cleared 510(K)
K
82
2287
BX-500 ELECTRONIC MUSCLE EXERCISER
2
Cleared 510(K)
K
82
2056
EXER-STIM CONTROLLER
2
Cleared 510(K)
K
82
2250
MYO-TONE, INC. SYSTEM-80
2
Cleared 510(K)
K
82
2284
COMPLY NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
82
1449
P6S ATHLETIC
2
Cleared 510(K)
K
82
0953
EF2000
2
Cleared 510(K)
K
82
1110
ELECTRONIC MUSCLE EXERCISER
2
Cleared 510(K)
K
82
0080
BX-1000 ISOMATIC
2
Cleared 510(K)
K
82
1157
HETERODYNAMIC
2
Cleared 510(K)
K
82
0938
HAWKINS ELECTROKINETIC BODY ACTIVATING
2
Cleared 510(K)
K
82
0782
THERATRONIC STIMULATOR
2
Cleared 510(K)
K
82
0884
ELECTRICAL MUSCLE STIMULATOR
2
Cleared 510(K)
K
82
0784
CLINIC 2000 MODEL MULTI-FRECODYN DEVICE
2
Cleared 510(K)
K
81
3604
OMNI STIM II
2
Cleared 510(K)
K
81
3443
BX-400 SPORT
2
Cleared 510(K)
K
81
3410
BX-400 JESSE JIMBODY
2
Cleared 510(K)
K
81
3533
ELECTRIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
82
0168
MENTOR ACTIVATOR NEUROMUSCULAR STIMU
2
Cleared 510(K)
K
81
3181
ELECTROC-GYM
2
Cleared 510(K)
K
81
3108
MODEL 500 VERI/500
2
Cleared 510(K)
K
81
3456
HIGH VOLTAGE GALVANIC STIMULATOR 550
2
Cleared 510(K)
K
81
2984
SLIMTRONICS 2000
2
Cleared 510(K)
K
81
2851
SBP-16 CLINIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
81
3008
RESPOND II...NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
81
2538
ELITE
2
Cleared 510(K)
K
81
1737
BIO-TONE MODEL 4
2
Cleared 510(K)
K
81
1395
EMPI MODEL 710, NMS
2
Cleared 510(K)
K
81
1502
STIMULATOR, FACIAL-MODELS SF-100 & 200
2
Cleared 510(K)
K
81
1250
ELECTRONIC MUSCLE STIMULATOR
2
Cleared 510(K)
K
81
0975
MINITONE
2
Cleared 510(K)
K
81
0634
FIRM-A-TRON
2
Cleared 510(K)
K
81
0513
ELECTRODYN CII-INTERFERENTIAL MUSCLE
2
Cleared 510(K)
K
81
0225
LITRONIC STIMULATOR
2
Cleared 510(K)
K
81
0246
ELITE
2
Cleared 510(K)
K
80
2804
NEMECTRODYN 8
2
Cleared 510(K)
K
81
0496
VERI/PMS MODEL 815
2
Cleared 510(K)
K
81
0247
MBI-4
2
Cleared 510(K)
K
80
3314
SKIN BEAUTY CLEANSER & TONER
2
Cleared 510(K)
K
81
0044
MUSCLE STIMULATOR
2
Cleared 510(K)
K
81
0064
PULSARII, HIGH VOLT. GALVANIC MUSC. STIM
2
Cleared 510(K)
K
81
0057
GALVANATOR 725
2
Cleared 510(K)
K
80
3064
ZIMMER ELECTRICAL MUSCLE STIMULATOR
2
Cleared 510(K)
K
80
2269
FIGURETRIM
2
Cleared 510(K)
K
80
2107
EGS #300 BATTERY OPER. PORTA. MUSCLE STI
2
Cleared 510(K)
K
80
1577
NEUROGAR IV-EXTERNAL NEURO-MUSCLE STIM.
2
Cleared 510(K)
K
80
1790
INTELECT
2
Cleared 510(K)
K
80
1053
PULSED GALVANIC STIMULATOR, 450-DYNAMAX
2
Cleared 510(K)
K
80
0484
MOD. 3127 NEUROMUSCULAR STIMULATOR
2
Cleared 510(K)
K
80
0486
STIM-EX 201
2
Cleared 510(K)
K
80
0068
ELECTRICAL MUSCLE STIMULATOR (EMS)
2
Cleared 510(K)
K
79
1087
PORTABLE PULSE GALVANIC STIMULATOR
2
Cleared 510(K)
K
79
1048
STIMTECH NEUROMUSCULAR STIMULATOR, C 600
2
Cleared 510(K)
K
79
0847
EGS MODEL 300
2
Cleared 510(K)
K
79
0120
SLENDERTONE
2
Cleared 510(K)
K
79
0033
HVG-100
2
Cleared 510(K)
K
78
1239
MYO-STIM
2
Cleared 510(K)
K
78
1318
DYNATRON 406 ELECTROTHERAPY APPARATUS
2
Cleared 510(K)
K
78
1315
MUSCLE STIMULATION APPARATUS
2
Cleared 510(K)
K
78
1319
THERAPY APPAR. 422 INTERFERENTIAL
2
Cleared 510(K)
K
78
1139
MUSCLE STIMULATOR, ELECTRONIC
2
Cleared 510(K)
K
78
1113
MUSCLE STIMULATOR, ELECTRICAL
2
Cleared 510(K)
K
78
1167
STEMPLEX
2
Cleared 510(K)
K
78
1080
GALVANATOR, MODEL 770
2
Cleared 510(K)
K
78
0133
MUSCLE STIMULATOR, ELECTRICAL
2
Cleared 510(K)
K
77
0276
ELECTROTHERAPY APPARATUS E.T. 720
2
Cleared 510(K)
K
76
0462
ELECTRICAL SHOCK DEVICE
2
Cleared 510(K)
K
76
0547
STIMULATOR, ELECTRICAL MUSCLE (#MD-4)
2
Cleared 510(K)
K
76
1220
TECA MODEL SP5/T ELECTRO-THER. STIM.
2
Cleared 510(K)
K
76
0913
MICROTYNE UNIT
2
Cleared 510(K)
K
76
0503
STIMULATOR, ELECTRICAL MUSCLE (#MD-8)
2
Cleared 510(K)
IRN
Device, Warning, Overload, External Limb, Powered
2
Product Code
IRO
Vibrator, Therapeutic
1
Product Code
IRP
Massager, Powered Inflatable Tube
2
Product Code
IRQ
Unit, Heating, Powered
1
Product Code
IRR
Bars, Parallel, Powered
1
Product Code
IRS
Head Halter, Traction
1
Product Code
IRT
Pad, Heating, Powered
2
Product Code
ISA
Massager, Therapeutic, Electric
1
Product Code
ISD
Exerciser, Measuring
2
Product Code
ITH
Equipment, Traction, Powered
2
Product Code
JFA
Exerciser, Finger, Powered
1
Product Code
JFB
Table, Physical Therapy, Multi Function
2
Product Code
KNL
Board, Scooter, Prone
1
Product Code
KNM
Device, Pressure Applying
1
Product Code
KTB
Device, Iontophoresis, Specific Uses
2
Product Code
KTC
Bath, Sitz, Nonpowered
1
Product Code
LBG
Device, Fluidized Therapy, Dry Heat
2
Product Code
LSB
Unit, Fluidotherapy
2
Product Code
LXF
Diathermy, Ultrasonic, For Use Other Than Applying Therapeutic Deep Heat
3
Product Code
LXJ
Interactive Rehabilitation Exercise Devices
2
Product Code
LYG
Massager, Therapeutic, Manual
1
Product Code
MPO
Infant Heel Warmer (Chemical Heat Pack)
1
Product Code
NGX
Stimulator, Muscle, Powered, For Muscle Conditioning
2
Product Code
NHN
Powered Light Based Laser Non-Thermal Instrument With Non-Heating Effect For Adjunctive Use In Pain Therapy
2
Product Code
NYY
Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation
2
Product Code
NYZ
Stimulator, Muscle, Powered, With Limited Output, For Muscle Conditioning
2
Product Code
OMW
Adhesive Backed Thermal Skin Patches
1
Product Code
OSD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature
2
Product Code
PCD
Powered Stairway Chair Lift
2
Product Code
PFW
Stationary Ultrasonic Diathermy Device For Use In Applying Therapeutic Deep Heat
2
Product Code
PHW
Cold Pack And Vibrating Massager
1
Product Code
PKS
Exerciser, Non-Measuring For Stroke Rehabilitation
1
Product Code
PQY
Nonthermal Shortwave Therapy Device Indicated For Over The Counter Use For The Treatment Of Pain
2
Product Code
QKC
Interactive Rehabilitation Exercise Device, Prescription Use
2
Product Code
QKD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature, Prescription Use
2
Product Code
QTC
Adult Portable Bed Rails For Medical Purposes
1
Product Code
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 26 September 2025 at 11:05 pm
PM
/
subpart-f—physical-medicine-therapeutic-devices
/
IPF
/
K930670
View Source
PHYACTION 787
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K930670
510(k) Type
Traditional
Applicant
VERIMED HOLDINGS, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
7/2/1993
Days to Decision
143 days
Submission Type
Statement
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
Subpart D—Physical Medicine Prosthetic Devices
Subpart E—Surgical Devices
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
MOC
Cushion, Flotation, Therapeutic
IMG
Stimulator, Ultrasound And Muscle, For Use In Applying Therapeutic Deep Heat
IMI
Ultrasonic Diathermy For Use In Applying Therapeutic Deep Heat
IMJ
Diathermy, Shortwave, For Use In Applying Therapeutic Deep Heat
QOL
Electroencephalography (Eeg)-Driven Upper Extremity Powered Exerciser
QRA
Virtual Reality Behavioral Therapy Device For Pain Relief
BXB
Exerciser, Powered
EGJ
Device, Iontophoresis, Other Uses
HPH
Diathermy, Microwave, For Use Other Than Applying Therapeutic Deep Heat
IKW
Utensil, Homemaking
IKX
Aid, Transfer
IKZ
Bed, Patient Rotation, Powered
ILC
Utensil, Eating
ILD
Adaptor, Dressing
ILJ
Bath, Hydro-Massage
ILK
Transport, Patient, Powered
ILM
Bath, Sitz, Powered
ILO
Pack, Hot Or Cold, Water Circulating
ILS
Adaptor, Hygiene
ILT
Adaptor, Recreational
ILW
Adaptor, Grooming
ILX
Diathermy, Shortwave, For Use Other Than Applying Therapeutic Deep Heat
ILY
Lamp, Infrared, Therapeutic Heating
ILZ
Accessories, Traction
IMA
Pack, Heat, Moist
IMB
Cabinet, Moist Steam
IMC
Bath, Paraffin
IMD
Pack, Hot Or Cold, Disposable
IME
Pack, Hot Or Cold, Reusable
IMF
Unit, Chilling
INX
Bed, Air Fluidized
INY
Bed, Patient Rotation, Manual
IOA
Diathermy, Microwave, For Use In Applying Therapeutic Deep Heat
IOB
Lamp, Infrared, Non Heating
IOD
Components, Exercise
IOE
Bars, Parallel, Exercise
IOG
Treadmill, Mechanical
IOL
Treadmill, Powered
ION
Exerciser, Non-Measuring
IOQ
Bed, Flotation Therapy, Powered
IPF
Stimulator, Muscle, Powered
K
24
1488
TrainFES Advance
K
24
0348
Quantum Mitohormesis (QMT) (M2101)
K
24
0992
eMVFit (MVF-10M)
K
24
0234
BTL-899MS
K
23
3098
MYOTouch Muscle Stimulator
K
23
2786
Stimulation System (PA series, PR series, S series and Q series)
K
23
3926
accufit
K
23
3485
M-Wave
K
23
2937
BTL-899M
K
23
0701
Stim2Go
K
23
1440
Combo Electrotherapy Device
K
22
3027
NeuroTrigger Basic (NTB)
K
22
3802
accufit
K
22
1274
StarFormer, TightWave
K
23
0167
BACK 4
K
23
2334
DEKA SIMON
K
21
3655
HiTop® (Models: HiToP®4touch, HiToP®2touch, HiToP®1touch)
K
22
2201
Biological Feedback and Stimulation System
K
22
1958
Flex-MI
K
22
0994
Shoulder PacemakerTM
K
21
3197
MyOnyx System
K
22
0738
Motive Knee Wrap
K
22
0327
geko W-3
K
21
3043
Levator Elite (Model LE9011)
K
21
2832
TimeWaver Frequency
K
21
2762
geko W-2
K
19
2746
MyoWorx TM20
K
21
0002
STELLA BIO
K
21
0674
Shoulder Pacemaker
K
21
0938
PowerDot PD-01MT2 Muscle Stimulator
K
21
1094
Nerve and Muscle Stimulator
K
21
0604
Intellihab System
K
21
0979
Prelivia
K
21
0572
Neurodyn V2.0, Neurodyn Aussie V2.0
K
20
2031
Talent-Pro Electromagnetic Stimulator
K
20
3710
Storz Medical MAGNETOLITH Muscle Stimulator
K
20
1285
InMode Evolve System with the Tone Applicator
K
21
0269
PowerDot PD-01MT2 Muscle Stimulator
K
20
3488
emField
K
20
2648
Biofeedback Nerve and Muscle Stimulator
K
20
2079
Physiq
K
20
2490
Avid CT2
K
20
0088
g.Estim FES
K
20
1290
Medline DeNovo 4Pro Electrical Stimulation Device
K
20
1958
ETD Family of Electrotherapy Devices
K
19
3275
Nerve and Muscle Stimulator
K
19
3045
geko™ W-2
K
18
3074
TENS and EMS Stimulator, TENS Stimulator
K
19
2733
RelieforMe TENS/EMS Device Model UPK-GE01
K
19
2249
InMode System with Tone Applicator
K
19
1113
geko T-2 and geko T-3 Neuromuscular Stimulators
K
18
2163
Shear Stress Therapeutics SST 3000
K
18
1759
PowerDot PD-01MT
K
18
1688
R-C1 TENS and EMS Stimulator; R-E1- EMS Stimulator; R-T1 TENS Stimulator
K
18
1059
geko T-3 Neuromuscular Stimulator
K
17
2381
Digitimer DS7AP Constant Current Stimulator
K
18
0082
geko T-2 and geko Plus R-2
K
17
1978
Combo Stimulator MT9000, Combo Stimulator LT7102, TENS Stimulator InTENSity 10
K
17
1071
StimSox(TM) System
K
17
1387
EMS100 Tri-Wave Combination Stimulator
K
16
3125
geko™ T-2 and geko™ Plus R-2 Neuromuscular Stimulators
K
16
2987
FA100 SCCD (Sequential Continuous Contraction Device)
K
16
0614
Xcite Clinical Station
K
16
3067
CyMedica e-vive™ System; CY-1000
K
16
0992
HPM-6000
K
15
1922
StimSox(TM) System
K
15
3696
Chattanooga Revolution Wireless
K
16
0299
geko(TM) Plus R-2 Neuromuscular Stimulator
K
15
3224
VitalStim(R) Plus Electrotherapy System
K
15
2677
geko T-2 Neuromuscular Stimulator
K
15
0742
Muscle Stimulation System 110
K
15
0413
QB1 System Powered Muscle Stimulator & Transcutaneous Electrical Nerve Stimulator
K
14
0467
FLEX-MT +
K
13
3638
GEKO
K
13
1917
NEURODYN COMPACT, NEURODYN II
K
13
2284
VECTRA NEO CLINICAL THERAPY SYSTEM
K
13
0691
ELECTROTHERAPY DEVICE (COMBO UNIT)
K
13
0052
TONE-A-MATIC
K
13
1629
NEURODYN MULTIWAVE, AUSSIE SPORT
K
13
1222
AMPCARE ESP THERAPY SYSTEM
K
13
2137
MULTISTIM
K
13
0424
STIMEL-03
K
12
3354
REVITIVE IX
K
12
4016
EMPI PHOENIX
K
12
3642
MUSCLE STIMULATION SYSTEM
K
12
0922
GUARDIAN DYSPHAGIA DUAL CHANNEL NMES UNIT
K
11
3010
FDES100(TENS AND EMS STIMULATOR, FDES102(ED402) TENS STIMULATOR
K
11
3017
SYS*STIM 240
K
11
2148
POWERED MUSCLE STIMULATOR
K
11
2348
RS-4I MUSCLE STIMULATOR
K
11
1279
NEXWAVE COMBO MUSCLE STIMULATOR SYSTEM
K
10
3738
H-WAVE
K
10
0862
BODYFLOW P2CH
K
09
2202
ESWALLOW DYSPHAGIA THERAPY KIT, PMI DYSPHAGIA THERAPY KIT
K
10
2202
GS 3000
K
09
3324
EMPI CONTINUUM
K
09
3138
MT9000 SERIES ELECTRO-STIMULATOR, MODELS MT9000, MT9002, MT9001, MT9004 AND MT9003
K
10
0117
LT3000 COMBO STIMULATOR, LT3001 TENS STIMULATORY, LT3002 EMS STIMULATOR
K
09
2791
KNEEHAB XP CONTROLLER, MODEL 411
K
09
3259
ARP RX100
K
09
1248
MAXEMS, MODELS 1000 AND 2000
K
09
0532
T.E.A.R. TECH3
K
08
3105
KNEEHAB XP CONDUCTIVE GARMENT, TYPE 411
K
09
0632
COMPEX REHAB
K
08
0950
STIWELL MED4
K
07
1677
SRT II MUSCLE STIMULATOR
K
07
0888
COMBI 8 MAX
K
08
0787
BIOMOVE 5000 SYSTEM
K
08
0661
MODELS TENS 7000, EMS 7500 AND TWIN STIM
K
07
3361
MUSCLE PAIN DEVICE (MPD)
K
07
2252
VEINOPLUS NEUROMUSCULAR STIMULATOR
K
06
3642
FD EMS, MODEL # D-FJ30E
K
07
1093
SAN SHIH POWERED MUSCLE STIMULATOR, MODEL 202
K
07
2795
MODELS EMS 5.0, EMS 5.1
K
07
1431
GLOBUS GENESY 1100 STIMULATOR
K
07
1320
EVERLIFE POWERED MUSCLE STIMULATOR, MODEL E-100204, E-100504, E-100509, E-100804, E-201111, E-201211, E-201311
K
07
0425
VITALSTIM EXPERIA
K
06
2453
KINGLY STAR POWERED MUSCLE STIMULATOR, MODEL KS-138
K
06
2354
VECTRA GENISYS VMS FR
K
05
3285
MAGBODY DT-1200, DT-1200T, DT-1200M, DT-1200PT, DT-1200PM
K
05
3266
MYOTRAC INFINITI
K
05
0921
EASYSTIM NMS-28
K
05
1135
AXIOM NVP8500
K
05
0687
AXIOM EPS8000
K
05
0847
IF TRUE SINE INTERFERENTIAL STIMULATOR, MODEL WL-2206A
K
05
0595
FT2000 SEQUENCER FOR MUSCLE STIMULATOR
K
05
0046
REHABILICARE IF 3 WAVE INTERFERENTIAL STIMULATOR SYSTEM, MODEL 7110S
K
02
4258
NEUROTECH KNEEHAB
K
04
1390
DIAMOND MEDISTIM
K
04
2650
BIOMOVE 3000
K
04
1920
INFINITY PLUS ELECTROTHERAPY SYSTEM
K
04
1063
SMARTWAVE MS 2000
K
04
2881
PMD-2000 INTERFERENTIAL STIMULATOR
K
03
4005
SDS-4I
K
04
0849
MENTAMOVE
K
03
2954
ELPHA, MODELS II 500, II 1000, II 2000, II 3000 AND E80
K
03
3174
BMLS03-3
K
04
1146
CONTROL SOLUTIONS, INC., MODEL CS3102 HVG
K
03
1310
TAI SHENG VARIOUS NEOX POWERED MUSCLE STIMULATOR
K
04
0306
HIGH VOLTAGE PULSED STIMULATOR, MODEL BMLS02-7
K
03
2955
AUTOMOVE, MODEL AM800
K
03
3544
ELECTRICAL MUSCLE STIMULATOR, MODELS N605 AND N607
K
03
1375
BESMED VARIOUS MODELS OF POWERED MUSCLE STIMULATOR, BE-560/BE-580
K
03
1820
ELECTRONIC MUSCLE MASSAGE, MODELS BE-550 AND BE-660
K
03
3140
NEUROMUSCULAR ELECTRICAL STIMULATOR, MODEL EV-807P
K
02
3000
HOME CARE VARIOUS MODELS OF POWERED MUSCLE STIMULATOR, HT-329M SERIES
K
03
2941
AUTOSOUND 7.6 MUSCLE STIMULATOR, TENS, THERAPEUTIC ULTRASOUND AND COMBINATION DEVICE
K
03
2178
RHYTHM TOUCH Q 2-WAY
K
03
0998
MEDRELIEF SE SERIES, MODELS SE-50, SE-100, SE-200, SE-300
K
03
2652
RS-4I MUSCLE STIMULATOR FAMILY
K
03
1427
ELECTRO NEUROMUSCULAR STIMULATOR, MODEL BMLS03-1
K
03
0403
CEFAR REHAB 2 AND REHAB 2 PRO
K
02
0478
ELECTROMEDICARIN 900
K
03
1884
INTERFERENTIAL STIMULATOR, MODEL NETWAVE
K
02
4181
PRIZM MEDICAL, INC. MICRO-Z STIMULATION SYSTEM
K
02
3036
CARE ETS
K
03
1017
SYS*STIM 208 AND 208A
K
03
0507
T.E.A.R. TECH3 MODEL #44TT03
K
02
2998
HOME CARE VAREIOUS MODELS OF POWERED MUSCLE STIMULATOR, HT-311, HT-311N, HT-312
K
02
3230
ECHOPULSE MUSCLE STIMULATOR SYSTEM, MODEL 800
K
02
3001
HOME CARE VARIOUS MODELS OF POWERED MUSCLE STIMULATOR, HT-326L
K
03
0648
VECTORSURGE 5 MODEL 470
K
02
3997
TENSCARE ULTIMA NMS/EMS
K
03
0254
INTERFERENTIAL STIMULATOR, MODEL RTM1000
K
02
1588
ELECTRO NEUROMUSCULAR STIMULATOR, MODEL BMLS02-5
K
02
3439
MEDS-4 NEUROMUSCULAR STIMULATOR
K
02
3446
MEDS-3 NEUROMUSCULAR STIMULATOR
K
02
4036
PRODUCT LINE-COMBO STIMULATOR/SEQUENTIAL STIMULATOR, MODEL IF-5000
K
02
3347
VITAL STIM
K
02
0130
ROLOR POWERED MUSCLE STIMULATOR, MODEL GP-8016M
K
02
0750
DIGITAL ELECTRICAL MUSCLE STIMULATOR, MODEL EV-807 DIGITAL EMS
K
02
2493
EMS 400
K
02
2776
NESS SYSTEM
K
02
2175
P4 PHYSIO
K
02
1905
CLASSIC NMS
K
02
1472
HMS-DHR-3 NEUROMUSCULAR STIMULATOR
K
01
4019
NEUROTECH MEDISTIM PLUS, TYPE 291
K
01
3768
POWERED MUSCLE STIMULATOR
K
02
1754
APEX MEDICAL DIGITAL EMS TS1311, TS1312
K
02
1100
300 PV COMPLETE ELECTROTHERAPY SYSTEM
K
02
1763
RS2MI MUSCLE STIMULATOR FAMILY
K
02
0637
SELECT STIM
K
02
0684
FINESUN EMS STIMULATOR
K
02
0314
DIGI-PRO TENS, MODEL WL-2204 AND WL-2205
K
01
1588
SURETONE
K
01
3770
MODIFICATION TO: WINNER ST-2 STIMULATOR
K
01
3771
MODIFICATION TO: WINNER CM-2 MUSCLE STIMULATOR, TENS, THERAPEUTIC ULTRASOUND AND COMBINATION DEVICE
K
99
2099
BIO SPA INTELLIGENT
K
01
3081
MEDSTAR 150
K
01
2885
NEUROMOVE NM900
K
01
1913
SUN-TENS PALM TYPE R5/COMPACT WIRELES M2 EMS SERIES
K
00
0741
EMS JUMPER II DUAL CHANNEL NEUROMUSCULAR STIMULATOR SYSTEM, MODEL E-188
K
01
0749
ELECTRO NEUROMUSCULAR STIMULATOR, MODEL NMS-DIGITAL
K
00
2339
AEMS V, EMS-1000, MODEL TS-140500 AND AEMS VI, EMS-1000 PLUS, MODEL TS-140600
K
01
0807
MUSCLE STIMULATOR SA-100
K
00
2336
MS104A, NEWMINI II (EMS-II), MODEL AP-101050T AND MEDTRIM (EMS-V), MODEL AP-102050T
K
01
0745
EMS 3000
K
00
3433
NEURO-TRAIN III (3)
K
00
3596
SMITH & NEPHEW RESTIM
K
00
2410
FREED BIOELECTRIC: DYSPHAGIA TREATMENT DEVICE
K
00
2058
VECTORSURGE 5, MODEL VS-500
K
01
0665
TRANSAMERICA DIGITAL EMS
K
00
3260
VECTORSURGE 4 INTERFERENTIAL THERAPY UNIT MODEL VS 460
K
00
0808
RICH-MAR WINNER ST4 MUSCLE STIMULATOR, INTERFERENTIAL, AND TENS DEVICE
K
00
0114
RS-4M+MUSCLE STIMULATOR
K
99
3420
CONTROL SOLUTIONS INC, MODEL CS3101
K
99
4062
HMS NEUROMUSCULAR STIMULATOR
K
99
4065
MS-ONE, MODEL MS-1
K
99
3821
VECTORSURGE 4 INTERFERENTIAL THERAPY UNIT
K
99
1241
IF8000
K
99
0787
TRIO 300
K
99
0697
RS-4V MUSCLE STIMULATOR
K
98
4142
SONICATOR PLUS 992, MODEL NUMBER ME 992 AND SONICATOR PLUS 994, MODEL NUMBER ME 994
K
98
4114
SYS STIM 294, MODEL ME 294
K
98
4113
MS400
K
98
4021
MS300
K
98
2828
FORTE, MODELS CPS 400 STIM, CPS 200 STIM
K
98
2482
HANDMASTER NMS1
K
98
2388
SURGI STIM
K
98
0158
MYO-TRAIN V (5)
K
98
0040
ELECTRONIC MUSCLE STIMULATOR - MICROSTIM J-1304D
K
97
3929
NEOTONUS MS-101 MAGNETIC MUSCLE STIMULATOR SYSTEM
K
98
0958
HAKOMED ELECDT/VACUPULLS
K
98
0892
HAKOMED ELECDT / PRO ELEDT SERIES
K
98
0346
ELECTRICAL MUSCLE STIMULATOR DEVICE ( PGS-4000)
K
98
0448
MODEL PS-1 PENA MUSCLE STIMULATOR
K
97
3223
STELLAR MODEL HS-04
K
97
2997
AM800 AUTOMOVE EMG TRIGGERED ELECTRICAL MUSCLE STIMULATION
K
96
4434
SD-970EMS ELECTRICAL MUSCULAR STIMULATOR
K
96
1751
W.M.E. GPS 1001
K
97
0847
IMPULSE HVG
K
97
2055
MSI MAGNA-STYM
K
97
1542
ORTHO DX NEUROMUSCULAR STIMULATOR
K
95
5666
EGS4000
K
97
0155
NEURO-TRAIN II (2)
K
96
4028
SYS STIM 226
K
96
4423
AXIOM INF
K
95
0550
XH-1 NEUROMUSCULAR STIMULATOR
K
96
2462
MUSCLEMAX PLUS ELECTRICAL MUSCLE STIMULATOR
K
96
0457
ELECTRONIC MUSCLE STIMULATOR MODEL EMS-1C/EMS-2C
K
95
2273
HANDMASTER NMS1
K
95
5736
STIM-8
K
96
0433
VST-10, VST-10/2
K
95
5146
AXIOM-HVG
K
96
0489
ULTRA IV
K
96
0096
ULTRA III
K
95
4411
GALVA-5-M
K
95
1682
OCTOSTIM
K
95
2680
VARAPULSE-2
K
95
3136
RS-4M
K
95
1727
Z-WATCH SYSTEM
K
95
3615
FORTE ES-400
K
95
0783
4000+
K
94
3007
ITP-HVPC GALVANIC STIMULATOR
K
95
0617
SMART WAVE GS100
K
94
6186
CHAL-2500
K
94
3185
BX-200 SC
K
94
2195
BX-400S
K
94
4935
DYNATRON 250
K
94
6298
BIOSTIM-HV
K
93
2075
MASTERSTIM 1-4
K
94
5510
FX-4 NMS (4CHANNEL TABLE MODEL)
K
94
5509
FX-2 NMS (2CHANNEL TABLE MODEL)
K
94
5508
FX-2P NMS (2 CHANNEL PORTABLE)
K
94
0301
COMPEX 2
K
93
4556
EMS-250
K
93
3194
THE SIGNATURE SERIES, IMC IV
K
93
3196
THE SIGNATURE SERIES, IC II
K
94
1049
MUSCLEMAX ELECTRICAL MUSCLE STIMULATOR
K
93
4919
THE SIGNATURE SERIES, MAGNUM 100
K
94
0349
NEUROMUSCULAR ELECTRICAL STIMULATOR
K
93
3653
MS 2500
K
93
1401
EMS
K
93
2898
POWERED MUSCLE STIMULATOR
K
92
6084
HVGS 9000
K
93
3195
THE SIGNATURE SERIES, IC IV
K
93
2916
GALVANIC GENERATOR MODEL IMF4150/A
K
93
2739
FAST START NEUROMUSCULAR STIMULATOR
K
93
3072
PCI 2500
K
93
3249
DYNATRON 100 PLUS
K
93
3176
NEUROTECH 2000 (NT2000)
K
93
1781
JACE TRI-STIM DEVICE
K
93
2764
THERAPEUTIC STIMULATOR 300(TS-300) & 300P(TS-300P)
K
93
2610
PCI 4000
K
93
2596
NT4-PLUS
K
93
2399
THERAPEUTIC STIM 200 (TS-200)/200P (TS-200P)
K
92
6510
STAODYN EMS+2
K
92
6410
ULTRATONE 8+ & 20
K
92
6265
NEURO-CARE 1000
K
93
0670
PHYACTION 787
K
92
4699
PMP MUSCLE STIMULATOR
K
92
3498
BIPHASIC UNIT
K
92
3501
HIGH VOLT UNIT
K
92
5680
LSI SYSTEM IV INTERFERENTIAL,MUSCLE STIMULATOR
K
92
0389
RS-2 NEUROMUSCULAR STIMULATOR
K
92
0388
RS-1 NEUROMUSCULAR STIMULATOR
K
92
3914
IF-II (TM), MODEL 7200
K
91
2328
ELECTRONIC MUSCLE STIMULATORS, EXCEL II, MODIFIED
K
92
1668
STAODYN TUWAVE
K
92
0532
ACU-TRAIN V (5)
K
91
5321
BTM-200 (PROPOSED) POWERED MUSCLE STIMULATOR
K
91
2462
Q-MS NEUROMUSCULAR STIMULATOR
K
91
4231
ELPHA 2000
K
92
0833
RICH-MAR HV 1000 MUSCLE STIMULATOR
K
92
0436
MEDTRONIC RESPOND III NEUROMUSCULAR STIMULATOR
K
91
5230
H WAVE MUSCLE STIMULATOR
K
91
4904
THERAPEUTIC STIMULATOR 2100 (TS-2100)
K
91
4999
BTM-100 POWERED MUSCLE STIMULATOR (PROPOSED)
K
90
3870
KINESTHETICS MODEL 2000 NMS
K
90
4509
POWER TRAINER WITH NEUROMUSCULAR STIMULATION
K
91
4539
RICH-MAR IFV 1000
K
90
3148
CHALLENGE 3000 NEUROLOGICAL BOOSTER
K
91
2642
EMS300, EMS400, EMS8000
K
91
2342
DR. LIBERSON'S MICROPULSE NEUROMUSCULAR TRANS STIM
K
91
3444
GLOBALCARE EMS
K
90
4360
CHALLENGE 4010 ONE CHANNEL WIDE PULSE STIMULATOR
K
91
0801
HIGH VOLTAGE PULSED GALVANIC STIMULATION APPLICATI
K
91
3272
EMS/400
K
90
5107
UTS ELECTRICAL MUSCLE STIMULATION DEVICE-PGS 1500
K
90
4332
MSTIM-2000 EMS
K
90
3711
RHEOLOGIC I
K
90
3149
CHANLLENGE 1010 PATIENT KEY PROGRAM STATION
K
90
2255
OMRON PULSE STIMULATOR MODEL HV-F05
K
90
2599
REVISED HIGH VOLTAGE STIMULATOR INTELECT 150
K
90
0647
SOUTHERN CROSS HI-V4 PULSED HIGH VOLTAGE GALVANIC
K
90
2371
HAELAN 340 MUSCLE STIMULATOR
K
90
2513
CHALLENGE 6010 POWERED MUSCLE STIMULATOR
K
90
2514
CHALLENGE 5010 POWERED MUSCLE STIMULATOR
K
90
2512
CHALLENGE 8000 POWERED MUSCLE STIMULATOR
K
90
2511
CHALLENGE 7010 POWERED MUSCLE STIMULATOR
K
90
1849
LUMISCOPE EMS 8000
K
89
3980
LINDQUIST MODEL 370
K
89
2960
LINDQUIST MODEL SS POWERED MUSCLE STIMULATOR
K
90
1770
CHALLENGE 7000 POWERED MUSCLE STIMULATOR
K
90
1769
CHALLENGE 6000 POWERED MUSCLE STIMULATOR
K
90
1768
CHALLENGE 5000 POWERED MUSCLE STIMULATOR
K
90
1779
RICH-MAR BP-2000 ELECTRICAL MUSCLE STIMULA. UNIT
K
90
1326
CHALLENGE 20 POWERED MUSCLE STIMULATOR
K
88
1431
SIEMENS STEREODYNATOR 828
K
90
0029
SPECTRASTIM 2000 MUSCLE STIMULATOR
K
90
0823
ISOTRON 220
K
90
0413
INTELECT 775MP POWERED MUSCLE STIMULATOR
K
89
3220
VERIMED MYOEXORCISER VERISTIM
K
89
6908
EXCEL STIM II
K
89
6836
EXCEL STIM
K
89
5983
MULTISTIM PLUS
K
89
5301
EMS 8100
K
89
1987
BIO-STYM 250 (MUSCLE STIMULATOR)
K
89
5760
ELECTRICAL MUSCLE STIMULATOR--PGS 2000 TENS DEVICE
K
89
3878
SYS*STIM 206A
K
89
3879
SYS*STIM 207A
K
89
3994
IF2000 ELECTRICAL MUSCLE STIMULATOR UNIT
K
89
5671
STIMTRAC II CATALOG NUMBER 78-8500
K
89
3851
THERASTIM
K
88
4651
ELECTRO NEUROMUSCULAR STIMULATOR MODEL 2000
K
89
1458
SW 803 LOW FREQUENCY STIMULATOR DANA TOUCH
K
88
2386
AGAR 3K NEUROMUSCULAR STIMULATOR
K
89
0434
EMS 300 MUSCLE STIMULATORS
K
88
2387
AGAR 4000 NEUROMUSCULAR STIMULATOR
K
88
1777
LIKON
K
89
3964
SPECTRASTIM TM 1000
K
87
5317
ELECTRICAL MUSCLE STIMULATOR MODEL MYOAID
K
88
1196
AM 706 ELECTROMYOGRAPH, STIM., NEURO., EXTERNAL
K
88
4396
MODIFIED THER-A-PULSE UNIT
K
89
0147
RICH-MAR CONDUCTIVE GEL II W/ALOE VERA
K
88
1470
SOKEN PLUS(TM) ELECTRONIC MUSCLE STIMULATOR
K
87
4232
MUSCLE STIM. DEVICES, BM 2000,4000,6000,8000
K
87
4212
VERIMED MYO/PREMS
K
88
0699
ENDOMED CV405
K
88
0948
RICH-MAR G1000 EMS
K
88
1024
ARCHGAUGE(TM)
K
88
0235
INTELECT MODEL 120
K
88
1082
GV 11 (TM), MODEL 9700
K
87
5238
SIEMENS NEUROTON 826 AND 827
K
88
0234
INTELECT VMS 2, OR INTELECT VMS II
K
87
4736
RICH-MAR HV-2000 ELECTRICAL MUSCLE STIMULATOR
K
87
1421
MODEL HL-100 PORTABLE DC ELECT. THERAPEUTIC UNIT
K
87
4076
MODIFIED OMNISTIM(TM) ELECTRICAL MUSCLE STIMULATOR
K
87
3125
SOKEN(TM) ELECTRONIC MUSCLE STIMULATOR
K
87
2606
TELESONIC BODY STIMULATOR
K
87
2970
THER-A-PULSE
K
87
2974
DYNATRAC
K
87
2036
RICH-MAR CONDUCTIVE GEL
K
87
2655
INTELECT 775
K
87
2207
MS-108, POWERED MUSCLE STIMULATOR
K
87
2206
MD-104, POWERED MUSCLE STIMULATOR
K
87
2208
MS-112, POWERED MUSCLE STIMULATOR
K
87
2753
MYOSTIM(TM), MODEL 6600
K
87
2654
INTELECT MODEL 575
K
87
0947
DYNATRON 500
K
87
1472
KINESTIM MUSCLE STIMULATOR
K
87
0515
DYNATRON 438
K
87
0774
TRU-STIM MUSCLE STIMULATOR
K
86
5070
CHIRO-STIM
K
86
5054
STIMUTRON MODEL 100
K
86
4625
MYOPAC (TM), MODEL 9600
K
86
4558
U66 EMS
K
86
4284
MUSCLE MASTER (MEDIUM VOLTAGE STIMULATOR)
K
86
4010
EMPI MODEL 712, LOGIX(TM), NMS
K
86
2685
MUSCLE MASTER (BIPOLAR STIMULATOR)
K
86
2485
MS-179 ELECTRONIC MUSCLE STIMULATOR
K
86
2486
MS-159 ELECTRONIC MUSCLE STIMULATOR
K
86
2487
MS-139 ELECTRONIC MUSCLE STIMULATOR
K
86
2031
HAWKINS MINI-E.B.A.
K
86
1136
INTERSTIM 100 SYSTEM
K
86
1796
FITTRONIC
K
86
0314
NEUROTECH-4 PROGRAM NEUROMUSCULAR STIMULATOR 281
K
86
0315
NEUROTECH-16 PROGRAM SYSTEM CONTROLLER MODEL 280
K
85
4485
RICH-MAR IF 200
K
86
1739
TEC PORTAMAX H.V. PULSED GALVANIC STIMULATOR
K
86
0619
ES 180-DCM MUSCLE STIMULATOR
K
86
0758
VACO SUCTION ELECTRODE UNIT
K
86
0107
SYS*STIM 206 (MODEL-ME 206)
K
85
5249
MIDIFICATION SYS*STIM 207 (MODEL-ME207)
K
85
3154
HV-4
K
85
4801
MS-189 MUSCLE STIMULATOR
K
85
4720
NEMECTRODYN MODEL 2 & ENDOVAC 2 POWER MUSCLE STIM.
K
85
4775
EMPI MODEL 730 NMS
K
85
4774
EMPI MODEL 720 NMS
K
85
3750
SYS*STIM 207 MODEL ME 207
K
85
2077
VERSA STIM 380, MUSCLE STIMULATOR
K
84
4727
MODEL 1000
K
85
1046
MYOCARE PLUS DUAL CHANNEL STIMULATOR
K
85
0850
AUTOMOVE/OMNISTIM IV-ELECTRICAL MUSCLE STIMULATOR
K
84
4126
SONTEC II
K
85
1037
ORTHOTRON MUSCLE STIMULATOR MK II DC
K
85
0698
MEDIUM FREQU. ELEC. MUSCLE STIMULATOR
K
85
0453
SINUS AC-POWERED MUSCLE STIMULATOR
K
84
4387
ESCOTEK-EST 221 VACUUM UNIT
K
84
4390
ESCOTEK-EST 204 MULTI STIM
K
84
4389
ESCOTEK EST 210, HIGH VOLTAGE ELECTRO GALVANIC STI
K
84
4388
ESCOTEK EST 220 INTERFERENCE THERAPY UNIT
K
85
0013
SYS STIM 206(MODEL-ME 206) MUSCLE STIMULATOR
K
85
0047
SANYO ELECTRONIC MUSCLE STIMULATORS
K
84
4617
EXCEL TECH MST-7 ISOELECTRONIC THERAPY DEVICE
K
84
4489
ELECTRONIC MUSCLE STIMULATOR
K
84
4580
MEDCOLATOR MODEL HVX
K
84
4466
THE PROBE 100
K
83
3928
MYOPULSE
K
84
3583
FIRM-A-TRON MARK X
K
84
3638
HEALTH PULSE FA-222 POWER MUSCLE STIMUL
K
84
3488
ELECTROSTIM 380
K
84
2712
MEDCOLATOR MODEL GX
K
84
2803
INTERFERENZ 4
K
84
2804
DIADYN 4
K
84
2268
VACUPULSE VACUUM UNIT
K
84
1647
NEUROMEDICS ULTRASTIM 650-01
K
84
2142
BX-400
K
84
1779
ELECTRONIC MUSCLE EXERCISE EQUIPMENT
K
84
1579
MULTIPLEX I, INTERFERENTIAL CURRENT
K
84
1382
EMPI MODEL 712, LOGIX, NMS
K
84
1278
OMNISTIM III INTERFERENTIAL THERAPY
K
84
0895
ELECTRICAL NEURO-MUSCULAR STIMULATOR
K
84
1112
TTI REHABILATATION GYM SYS
K
84
0724
MUSCLE STIMULATOR X-10
K
84
0467
NEUROMUSCULAR STIMULATOR 3105
K
84
0346
NEUROMUSCLAR II
K
84
0149
BMR POWERSTIM
K
84
0148
BMR-16 CLINIC MUSCLE STIMULATOR
K
84
0147
BMR-2 MUSCLE STIMULATOR
K
83
3945
COSMODYN-S INTERFERENTIAL MUSCLE STIM
K
83
2805
BIONICARE STIMULATOR BIO-1
K
83
4092
MULTIPLE SOKEN 3 ELECTRON-MUSCLE STIM
K
83
3808
NUTRA-TONE 500
K
83
2976
BX-600 EMS
K
83
2988
STAODYN EMS/PLUS
K
83
2546
MARK V HIGH VOLTAGE GALVANIC STIMULATORR
K
83
1473
ULTRA PULSATOR MF
K
83
1003
MEASURE-UP MUSCLE STIMULATOR
K
83
0055
RICH-MAR HV 20
K
82
2924
MINISTIM 180
K
82
3279
RESPOND QUADRIFLEX #3129 SINGLE CHANNEL
K
82
2519
HAWKINS EBA -16 MUSCLE STIMULATOR
K
82
2287
BX-500 ELECTRONIC MUSCLE EXERCISER
K
82
2056
EXER-STIM CONTROLLER
K
82
2250
MYO-TONE, INC. SYSTEM-80
K
82
2284
COMPLY NEUROMUSCULAR STIMULATOR
K
82
1449
P6S ATHLETIC
K
82
0953
EF2000
K
82
1110
ELECTRONIC MUSCLE EXERCISER
K
82
0080
BX-1000 ISOMATIC
K
82
1157
HETERODYNAMIC
K
82
0938
HAWKINS ELECTROKINETIC BODY ACTIVATING
K
82
0782
THERATRONIC STIMULATOR
K
82
0884
ELECTRICAL MUSCLE STIMULATOR
K
82
0784
CLINIC 2000 MODEL MULTI-FRECODYN DEVICE
K
81
3604
OMNI STIM II
K
81
3443
BX-400 SPORT
K
81
3410
BX-400 JESSE JIMBODY
K
81
3533
ELECTRIC MUSCLE STIMULATOR
K
82
0168
MENTOR ACTIVATOR NEUROMUSCULAR STIMU
K
81
3181
ELECTROC-GYM
K
81
3108
MODEL 500 VERI/500
K
81
3456
HIGH VOLTAGE GALVANIC STIMULATOR 550
K
81
2984
SLIMTRONICS 2000
K
81
2851
SBP-16 CLINIC MUSCLE STIMULATOR
K
81
3008
RESPOND II...NEUROMUSCULAR STIMULATOR
K
81
2538
ELITE
K
81
1737
BIO-TONE MODEL 4
K
81
1395
EMPI MODEL 710, NMS
K
81
1502
STIMULATOR, FACIAL-MODELS SF-100 & 200
K
81
1250
ELECTRONIC MUSCLE STIMULATOR
K
81
0975
MINITONE
K
81
0634
FIRM-A-TRON
K
81
0513
ELECTRODYN CII-INTERFERENTIAL MUSCLE
K
81
0225
LITRONIC STIMULATOR
K
81
0246
ELITE
K
80
2804
NEMECTRODYN 8
K
81
0496
VERI/PMS MODEL 815
K
81
0247
MBI-4
K
80
3314
SKIN BEAUTY CLEANSER & TONER
K
81
0044
MUSCLE STIMULATOR
K
81
0064
PULSARII, HIGH VOLT. GALVANIC MUSC. STIM
K
81
0057
GALVANATOR 725
K
80
3064
ZIMMER ELECTRICAL MUSCLE STIMULATOR
K
80
2269
FIGURETRIM
K
80
2107
EGS #300 BATTERY OPER. PORTA. MUSCLE STI
K
80
1577
NEUROGAR IV-EXTERNAL NEURO-MUSCLE STIM.
K
80
1790
INTELECT
K
80
1053
PULSED GALVANIC STIMULATOR, 450-DYNAMAX
K
80
0484
MOD. 3127 NEUROMUSCULAR STIMULATOR
K
80
0486
STIM-EX 201
K
80
0068
ELECTRICAL MUSCLE STIMULATOR (EMS)
K
79
1087
PORTABLE PULSE GALVANIC STIMULATOR
K
79
1048
STIMTECH NEUROMUSCULAR STIMULATOR, C 600
K
79
0847
EGS MODEL 300
K
79
0120
SLENDERTONE
K
79
0033
HVG-100
K
78
1239
MYO-STIM
K
78
1318
DYNATRON 406 ELECTROTHERAPY APPARATUS
K
78
1315
MUSCLE STIMULATION APPARATUS
K
78
1319
THERAPY APPAR. 422 INTERFERENTIAL
K
78
1139
MUSCLE STIMULATOR, ELECTRONIC
K
78
1113
MUSCLE STIMULATOR, ELECTRICAL
K
78
1167
STEMPLEX
K
78
1080
GALVANATOR, MODEL 770
K
78
0133
MUSCLE STIMULATOR, ELECTRICAL
K
77
0276
ELECTROTHERAPY APPARATUS E.T. 720
K
76
0462
ELECTRICAL SHOCK DEVICE
K
76
0547
STIMULATOR, ELECTRICAL MUSCLE (#MD-4)
K
76
1220
TECA MODEL SP5/T ELECTRO-THER. STIM.
K
76
0913
MICROTYNE UNIT
K
76
0503
STIMULATOR, ELECTRICAL MUSCLE (#MD-8)
IRN
Device, Warning, Overload, External Limb, Powered
IRO
Vibrator, Therapeutic
IRP
Massager, Powered Inflatable Tube
IRQ
Unit, Heating, Powered
IRR
Bars, Parallel, Powered
IRS
Head Halter, Traction
IRT
Pad, Heating, Powered
ISA
Massager, Therapeutic, Electric
ISD
Exerciser, Measuring
ITH
Equipment, Traction, Powered
JFA
Exerciser, Finger, Powered
JFB
Table, Physical Therapy, Multi Function
KNL
Board, Scooter, Prone
KNM
Device, Pressure Applying
KTB
Device, Iontophoresis, Specific Uses
KTC
Bath, Sitz, Nonpowered
LBG
Device, Fluidized Therapy, Dry Heat
LSB
Unit, Fluidotherapy
LXF
Diathermy, Ultrasonic, For Use Other Than Applying Therapeutic Deep Heat
LXJ
Interactive Rehabilitation Exercise Devices
LYG
Massager, Therapeutic, Manual
MPO
Infant Heel Warmer (Chemical Heat Pack)
NGX
Stimulator, Muscle, Powered, For Muscle Conditioning
NHN
Powered Light Based Laser Non-Thermal Instrument With Non-Heating Effect For Adjunctive Use In Pain Therapy
NYY
Stimulator, Muscle, Powered, With Limited Output, For Rehabilitation
NYZ
Stimulator, Muscle, Powered, With Limited Output, For Muscle Conditioning
OMW
Adhesive Backed Thermal Skin Patches
OSD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature
PCD
Powered Stairway Chair Lift
PFW
Stationary Ultrasonic Diathermy Device For Use In Applying Therapeutic Deep Heat
PHW
Cold Pack And Vibrating Massager
PKS
Exerciser, Non-Measuring For Stroke Rehabilitation
PQY
Nonthermal Shortwave Therapy Device Indicated For Over The Counter Use For The Treatment Of Pain
QKC
Interactive Rehabilitation Exercise Device, Prescription Use
QKD
Massager, Therapeutic, To Internally Massage Trigger Points In The Pelvic Floor Musculature, Prescription Use
QTC
Adult Portable Bed Rails For Medical Purposes
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
PM
/
subpart-f—physical-medicine-therapeutic-devices
/
IPF
/
K930670
View Source
PHYACTION 787
Page Type
Cleared 510(K)
PDF
FDA Hosted PDF
* The FDA doesn't provide PDFs for all submissions.
510(k) Number
K930670
510(k) Type
Traditional
Applicant
VERIMED HOLDINGS, INC.
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
7/2/1993
Days to Decision
143 days
Submission Type
Statement