VECTRA TRANSPORTABLE COMBO AND STIM (SPECIALTY LINE DEALERS); INTELECT TRANSPORTABLE COMBO AND STIM (GENERAL LINE DEALER
K040285 · Chattanooga Group · IMG · Apr 12, 2004 · Physical Medicine
Device Facts
Record ID
K040285
Device Name
VECTRA TRANSPORTABLE COMBO AND STIM (SPECIALTY LINE DEALERS); INTELECT TRANSPORTABLE COMBO AND STIM (GENERAL LINE DEALER
Applicant
Chattanooga Group
Product Code
IMG · Physical Medicine
Decision Date
Apr 12, 2004
Decision
SESE
Submission Type
Traditional
Regulation
21 CFR 890.5860
Device Class
Class 2
Attributes
Therapeutic
Indications for Use
For VMS, VMS Burst, Russian, Monophasic Hi-Volt (NMES), Interferential and Premodulated (IFS) Relaxation of Muscle Spasms Prevention or retardation of disuse atrophy Increasing local blood circulation Muscle re-education Maintaining or increasing range of motion Immediate postsurgical stimulation of calf muscles to prevent venous thrombosis Additionally for Microcurrent, Interferential, Premodulated (IFS), VMS, VMS Burst, Asymmetrical Biphasic (TENS) and Symmetrical Biphasic (TENS) Symptomatic relief or management of chronic, intractable pain Post-traumatic acute pain Post-surgical acute pain For FES Stimulation of the muscles in the leg and ankle of partially paralyzed patients to provide flexion of the foot and thus improve the patient's gait For DC Continuous Mode Relaxation of muscle spasm For Ultrasound Application of therapeutic deep heat for the treatment of selected sub-chronic and chronic medical conditions such as: 1. Relief of pain, muscle spasms and joint contractures 2. Relief of pain, muscle spasms and joint contractures that may be associated with: a) Adhesive capsulitis b) Bursitis with slight calcification c) Myositis d) Soft tissue injuries e) Shortened tendons due to past injuries and scar tissues 3. Relief of sub-chronic and chronic pain and joint contractures resulting from: a) Capsular tightness b) Capsular scarring
Device Story
Vectra GENiSYS is a multi-modality therapeutic device combining ultrasound and electrical stimulation. It delivers therapeutic deep heat via ultrasound for musculoskeletal conditions and various electrical stimulation waveforms (VMS, Russian, Hi-Volt, Interferential, Premodulated, TENS, Microcurrent, FES, DC) for pain management, muscle re-education, and spasm reduction. Used in clinical settings by healthcare professionals. The device transforms electrical energy into therapeutic ultrasound or electrical pulses applied to the patient via applicators/electrodes. Clinicians select parameters based on patient condition to manage pain or improve physical function. Benefits include non-invasive pain relief, improved circulation, and functional gait improvement for partially paralyzed patients.
Clinical Evidence
No clinical data provided; substantial equivalence is based on technological characteristics and intended use comparisons to legally marketed predicate devices.
Technological Characteristics
Multi-modality system providing ultrasound and electrical stimulation. Waveforms include VMS, VMS Burst, Russian, Monophasic Hi-Volt, Interferential, Premodulated, Microcurrent, Asymmetrical/Symmetrical Biphasic (TENS), FES, and DC. Operates as a therapeutic stimulator and ultrasound generator. Connectivity and specific material standards are not detailed in the provided documentation.
Indications for Use
Indicated for patients requiring muscle spasm relaxation, disuse atrophy prevention, local blood circulation increase, muscle re-education, range of motion maintenance, or venous thrombosis prevention via postsurgical calf stimulation. Also indicated for symptomatic relief of chronic, intractable, post-traumatic, or post-surgical pain. FES indicated for partially paralyzed patients to improve gait via leg/ankle muscle stimulation. Ultrasound indicated for sub-chronic/chronic pain, muscle spasms, and joint contractures associated with conditions like adhesive capsulitis, bursitis, myositis, soft tissue injuries, and scar tissue.
Regulatory Classification
Identification
An ultrasound and muscle stimulator for use in applying therapeutic deep heat for selected medical conditions is a device that applies to specific areas of the body ultrasonic energy at a frequency beyond 20 kilohertz and that is intended to generate deep heat within body tissues for the treatment of selected medical conditions such as relief of pain, muscle spasms, and joint contractures, but not for the treatment of malignancies. The device also passes electrical currents through the body area to stimulate or relax muscles.
Related Devices
K031077 — VECTRA EPR SYSTEM AND INTELECT EPR SYSTEM · Chattanooga Group · Dec 11, 2003
K982317 — VECTRA COMBO · Chattanooga Group, Inc. · Feb 1, 1999
K982830 — FORTE, MODELS CPS 400 COMBO, CPS 200 COMBO · Chattanooga Group, Inc. · Nov 6, 1998
K062354 — VECTRA GENISYS VMS FR · Encore Medical L.P. · Jan 26, 2007
K023050 — RELIANT BTL 5000 PULS ELECTRICAL STIMULATION SYSTEM, RELIANT BTL 5000 SONO ULTRASOUND SYSTEM, RELIANT BTL 5000 COMBI · Reliant Technologies, Inc. · Feb 14, 2003
Submission Summary (Full Text)
{0}------------------------------------------------
Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the circle is an abstract symbol resembling an eagle or bird with three stylized wing-like shapes.
#### Public Health Service
Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850
APR 1 2 2004
Mr. Mick Davis Regulatory Analyst Chattanooga Group A Division of Encore Medical 4717 Adams Road P.O. Box 489 Hixson, Tennessee 37343-0489
Re: K040285
Trade Name: Vectra GENiSYS Regulation Numbers: 21 CFR 890.5860, 882.5890, 890.5850, 882.5810 Regulation Names: Ultrasound and muscle stimulator, Transcutaneous electrical nerve stimulator for pain relief, Powered muscle stimulator, External functional neuromuscular stimulator Regulatory Class: II
Product Codes: IMG, GZJ, IPF, GZJ
Trade Name: Vectra GENiSYS Regulation Number: Unclassified Regulation Name: Interferential current therapy stimulator Regulatory Class: II Product Code: LIH
Dated: February 5, 2004 Received: February 17, 2004
We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Devicc Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. "The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration.
If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register.
{1}------------------------------------------------
### Page 2 - Mr. Mick Davis
Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050.
This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market.
If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Office of Compliance at (301) 594-4659. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers, International and Consumer Assistance at its toll-free number (800) 638-2041 or (301) 443-6597 or at its Internet address http://www.fda.gov/cdrh/dsma/dsmamain.html
Sincerely yours,
Mark A. Millican
Celia M. Witten, Ph.D., M.D. Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health
Enclosure
{2}------------------------------------------------
510(k) Number (if known): Vectra (Intelect) Transportable Combo & Stim Device Name:
Indications for Use:
## For VMS, VMS Burst, Russian, Monophasic Hi-Volt (NMES), Interferential and Premodulated (IFS)
Relaxation of Muscle Spasms
Prevention or retardation of disuse atrophy
Increasing local blood circulation
Muscle re-education
Maintaining or increasing range of motion
Immediate postsurgical stimulation of calf muscles to prevent venous thrombosis
Additionally for Microcurrent, Interferential, Premodulated (IFS), VMS, VMS Burst, Asymmetrical Biphasic (TENS) and Symmetrical Biphasic (TENS)
Symptomatic relief or management of chronic, intractable pain
Post-traumatic acute pain
Post-surgical acute pain
#### For FES
Stimulation of the muscles in the leg and ankle of partially paralyzed patients to provide flexion of the foot and thus improve the patient's gait
#### For DC Continuous Mode
Relaxation of muscle spasm
#### For Ultrasound
Application of therapeutic deep heat for the treatment of selected sub-chronic and chronic medical conditions such as:
1. Relief of pain, muscle spasms and joint contractures
2. Relief of pain, muscle spasms and joint contractures that may be associated with:
a) Adhesive capsulitis
b) Bursitis with slight calcification
c) Myositis
d) Soft tissue injuries
e) Shortened tendons due to past injuries and scar tissues
3. Relief of sub-chronic and chronic pain and joint contractures resulting from:
a) Capsular tightness
b) Capsular scarring
(PLEASE DO NOT WRITE BELOW THIS LINE- CONTINUE ON ANOTHER PAGE
============================================================================================================================================================================== Concurrence of CDRH, Office of Device Evaluation
# Division of General. Restorative. and Neurological Devices
Prescription Use
(Per 21 CFR 801.109)
**10(k) Number** K040285
(Optional Format 1-2-96)
Panel 1
/
Ready
Predicate graph will load when search results are available.
Embedding visualization will load when search results are available.
PDF viewer will load when search results are available.
Loading panels...
Select an item from Submissions
Click any panel, subpart, regulation, product code, or device to see details here.
Section Matches
Results will appear here.
Product Code Matches
Results will appear here.
Special Control Matches
Results will appear here.
Loading collections...
Loading
My Alerts
You will receive email notifications based on the filters and frequency you set for each alert.
Sort by:
Create Alert
Search Filters
Agent Token
Create a read-only bearer token for Claude, ChatGPT, or other agents that can call HTTP APIs.