FDA Browser
by
Innolitics
Anesthesiology
Review Panel
Cardiovascular
Review Panel
Chemistry
Review Panel
Dental
Review Panel
Ear, Nose, Throat
Review Panel
Gastroenterology and Urology
Review Panel
General Hospital
Review Panel
Hematology
Review Panel
Immunology
Review Panel
Microbiology
Review Panel
Neurology
Review Panel
Obstetrical and Gynecological
Review Panel
Ophthalmic
Review Panel
Orthopedic
Review Panel
Pathology
Review Panel
Physical Medicine
Review Panel
Miscellaneous
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
CFR Sub-Part
Subpart D—Physical Medicine Prosthetic Devices
CFR Sub-Part
IMK
Wheelchair, Stair Climbing
2
Product Code
IML
Armrest, Wheelchair
1
Product Code
IMM
Footrest, Wheelchair
1
Product Code
IMN
Climber, Curb, Wheelchair
1
Product Code
IMO
Handrim, Wheelchair
1
Product Code
IMP
Cushion, Wheelchair
1
Product Code
IMQ
Attachment, Narrowing, Wheelchair
1
Product Code
IMR
Device, Anti-Tip, Wheelchair
1
Product Code
QNX
External Compression Device For Internal Jugular Vein Compression
2
Product Code
ILE
Sling, Arm, Overhead Supported
1
Product Code
ILG
Stocking, Elastic
1
Product Code
ILH
Splint, Hand, And Components
1
Product Code
ILI
Sling, Arm
1
Product Code
ILP
System, Communication, Non-Powered
1
Product Code
ILQ
System, Communication, Powered
2
Product Code
IMS
Support, Head And Trunk, Wheelchair
1
Product Code
IMW
Brake, Extension, Wheelchair
1
Product Code
IMX
Board, Lap, Wheelchair
1
Product Code
IMY
Armboard, Wheelchair
1
Product Code
IMZ
Holder, Crutch And Cane, Wheelchair
1
Product Code
INA
Hill Holder, Wheelchair
1
Product Code
INB
Attachment, Commode, Wheelchair
1
Product Code
INC
Cuff, Pusher, Wheelchair
1
Product Code
INE
Sling, Overhead Suspension, Wheelchair
1
Product Code
INF
Scale, Platform, Wheelchair
1
Product Code
ING
Elevator, Wheelchair, Portable
2
Product Code
INI
Vehicle, Motorized 3-Wheeled
2
Product Code
INK
Stretcher, Wheeled, Powered
2
Product Code
INM
Chair, With Casters
1
Product Code
INN
Chair, Adjustable, Mechanical
1
Product Code
INO
Chair, Positioning, Electric
2
Product Code
INP
Tips And Pads, Cane, Crutch And Walker
1
Product Code
INQ
Table, Powered
1
Product Code
INT
Plinth
1
Product Code
INW
Table, Mechanical
1
Product Code
IOR
Wheelchair, Mechanical
1
Product Code
IOY
Support, Arm
1
Product Code
IOZ
Splint, Abduction, Congenital Hip Dislocation
1
Product Code
IPG
Shoe, Cast
1
Product Code
IPL
Wheelchair, Standup
2
Product Code
IPM
Cover, Limb
1
Product Code
K
87
2488
ELASTO-GEL CAST & SPLINT PADS
1
Cleared 510(K)
K
82
3399
COVER LIMB
1
Cleared 510(K)
K
80
1627
COVER, LIMB
1
Cleared 510(K)
K
78
0905
LIMB COVER
1
Cleared 510(K)
K
77
0223
HEAVY FOAM HEEL & ELBOW PROTECTORS
1
Cleared 510(K)
K
76
1114
FOAM SLIPPERS
1
Cleared 510(K)
IPO
Orthosis, Pneumatic Structure, Rigid
3
Product Code
IPR
Crutch
1
Product Code
IPS
Cane
1
Product Code
IPT
Orthosis, Thoracic
1
Product Code
IPW
Orthosis, Sacroiliac, Soft
1
Product Code
IPX
Orthosis, Rib Fracture, Soft
1
Product Code
IPY
Orthosis, Lumbo-Sacral
1
Product Code
IQA
System, Environmental Control, Powered
2
Product Code
IQB
Belt, Wheelchair
1
Product Code
IQC
Wheelchair, Special Grade
2
Product Code
IQE
Orthosis, Lumbar
1
Product Code
IQF
Orthosis, Cervical-Thoracic, Rigid
1
Product Code
IQI
Orthosis, Limb Brace
1
Product Code
IQJ
Splint, Clavicle
1
Product Code
IQK
Orthosis, Cervical
1
Product Code
IQM
Splint, Temporary Training
1
Product Code
IQO
Device, Prosthesis Alignment
1
Product Code
IQP
Rotator, Transverse
1
Product Code
IQQ
Joint, Shoulder, External Limb Component
1
Product Code
IQW
Hook, External Limb Component, Powered
1
Product Code
IQX
Hook, External Limb Component, Mechanical
1
Product Code
IQZ
Hand, External Limb Component, Powered
1
Product Code
IRA
Hand, External Limb Component, Mechanical
1
Product Code
IRD
Joint, Elbow, External Limb Component, Mechanical
1
Product Code
IRE
Joint, Elbow, External Limb Component, Powered
1
Product Code
ISH
Component, External, Limb, Ankle/Foot
1
Product Code
ISL
Joint, Hip, External Limb Component
1
Product Code
ISM
Pylon, Post Surgical
1
Product Code
ISN
Cable
1
Product Code
ISP
Valve, Prosthesis
1
Product Code
ISR
Band Or Belt, Pelvic Support
1
Product Code
ISS
Prosthesis, Thigh Socket, External Component
1
Product Code
ISW
Assembly, Knee/Shank/Ankle/Foot, External
2
Product Code
ISY
Joint, Knee, External Limb Component
1
Product Code
ISZ
Unit, Wrist, External Limb Component, Mechanical
1
Product Code
ITC
Stirrup, External Brace Component
1
Product Code
ITG
Bandage, Cast
1
Product Code
ITI
Wheelchair, Powered
2
Product Code
ITJ
Walker, Mechanical
1
Product Code
ITM
Cage, Knee
1
Product Code
ITN
Splint, Denis Brown
1
Product Code
ITO
Twister, Brace Setting
1
Product Code
ITQ
Joint, Knee, External Brace
1
Product Code
ITS
Joint, Hip, External Brace
1
Product Code
ITW
Joint, Ankle, External Brace
1
Product Code
KFT
Assembly, Shoulder/Elbow/Forearm/Wrist/Hand, Mechanical
1
Product Code
KFW
Assembly, Shoulder/Elbow/Forearm/Wrist/Hand, Powered
1
Product Code
KFX
Assembly, Thigh/Knee/Shank/Ankle/Foot, External
2
Product Code
KGH
Unit, Wrist, External Limb Component, Powered
1
Product Code
KHY
Cane, Safety Walk
1
Product Code
KIC
Cushion, Flotation
1
Product Code
KID
Restraint, Wheelchair, Non-Protective
1
Product Code
KNN
Components, Wheelchair
1
Product Code
KNO
Accessories, Wheelchair
1
Product Code
KNP
Orthosis, Corrective Shoe
1
Product Code
KTD
Orthosis, Abdominal
1
Product Code
LBE
Stroller, Adaptive
1
Product Code
LFF
Unit, Activation, Breath Control
1
Product Code
MNE
Orthosis, Moldable, Supportive, Skin Protective
1
Product Code
MRI
Orthosis, Truncal/Orthosis, Limb
1
Product Code
NDA
Helmet, Cranial, For Protective Use
1
Product Code
NHF
Monitor, Orthotic/Prosthetic
1
Product Code
NJB
Orthosis, Truncal, For Dysmenorrhea
1
Product Code
NXE
Walker, Mechanical, Poly Vinyl Chloride (Pvc)
1
Product Code
OHI
Orthosis, Foot Drop
1
Product Code
PAE
Upper Extremity Prosthesis With Multiple Simultaneous Degrees Of Freedom And Controlled Via Cutaneous Electromyography
2
Product Code
PCE
Permanently Mounted Wheelchair Platform Lift
2
Product Code
PMV
Orthosis, Limb, For Back Pain
1
Product Code
QDT
Shoe With Adjustable Sole Units
1
Product Code
Subpart E—Surgical Devices
CFR Sub-Part
Subpart F—Neurological Therapeutic Devices
CFR Sub-Part
Subpart F—Physical Medicine Therapeutic Devices
CFR Sub-Part
Radiology
Review Panel
General and Plastic Surgery
Review Panel
Toxicology
Review Panel
Medical Genetics
Review Panel
Unknown
Review Panel
Last synced on 25 January 2026 at 3:41 am
PM
/
subpart-d—physical-medicine-prosthetic-devices
/
IPM
/
K770223
View Source
HEAVY FOAM HEEL & ELBOW PROTECTORS
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K770223
510(k) Type
Traditional
Applicant
ROBERT R. MOORE
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
2/23/1977
Days to Decision
20 days
FDA Browser
by
Innolitics
Anesthesiology
Cardiovascular
Chemistry
Dental
Ear, Nose, Throat
Gastroenterology and Urology
General Hospital
Hematology
Immunology
Microbiology
Neurology
Obstetrical and Gynecological
Ophthalmic
Orthopedic
Pathology
Physical Medicine
Miscellaneous
Subpart B—Physical Medicine Diagnostic Devices
Subpart D—Physical Medicine Prosthetic Devices
IMK
Wheelchair, Stair Climbing
IML
Armrest, Wheelchair
IMM
Footrest, Wheelchair
IMN
Climber, Curb, Wheelchair
IMO
Handrim, Wheelchair
IMP
Cushion, Wheelchair
IMQ
Attachment, Narrowing, Wheelchair
IMR
Device, Anti-Tip, Wheelchair
QNX
External Compression Device For Internal Jugular Vein Compression
ILE
Sling, Arm, Overhead Supported
ILG
Stocking, Elastic
ILH
Splint, Hand, And Components
ILI
Sling, Arm
ILP
System, Communication, Non-Powered
ILQ
System, Communication, Powered
IMS
Support, Head And Trunk, Wheelchair
IMW
Brake, Extension, Wheelchair
IMX
Board, Lap, Wheelchair
IMY
Armboard, Wheelchair
IMZ
Holder, Crutch And Cane, Wheelchair
INA
Hill Holder, Wheelchair
INB
Attachment, Commode, Wheelchair
INC
Cuff, Pusher, Wheelchair
INE
Sling, Overhead Suspension, Wheelchair
INF
Scale, Platform, Wheelchair
ING
Elevator, Wheelchair, Portable
INI
Vehicle, Motorized 3-Wheeled
INK
Stretcher, Wheeled, Powered
INM
Chair, With Casters
INN
Chair, Adjustable, Mechanical
INO
Chair, Positioning, Electric
INP
Tips And Pads, Cane, Crutch And Walker
INQ
Table, Powered
INT
Plinth
INW
Table, Mechanical
IOR
Wheelchair, Mechanical
IOY
Support, Arm
IOZ
Splint, Abduction, Congenital Hip Dislocation
IPG
Shoe, Cast
IPL
Wheelchair, Standup
IPM
Cover, Limb
K
87
2488
ELASTO-GEL CAST & SPLINT PADS
K
82
3399
COVER LIMB
K
80
1627
COVER, LIMB
K
78
0905
LIMB COVER
K
77
0223
HEAVY FOAM HEEL & ELBOW PROTECTORS
K
76
1114
FOAM SLIPPERS
IPO
Orthosis, Pneumatic Structure, Rigid
IPR
Crutch
IPS
Cane
IPT
Orthosis, Thoracic
IPW
Orthosis, Sacroiliac, Soft
IPX
Orthosis, Rib Fracture, Soft
IPY
Orthosis, Lumbo-Sacral
IQA
System, Environmental Control, Powered
IQB
Belt, Wheelchair
IQC
Wheelchair, Special Grade
IQE
Orthosis, Lumbar
IQF
Orthosis, Cervical-Thoracic, Rigid
IQI
Orthosis, Limb Brace
IQJ
Splint, Clavicle
IQK
Orthosis, Cervical
IQM
Splint, Temporary Training
IQO
Device, Prosthesis Alignment
IQP
Rotator, Transverse
IQQ
Joint, Shoulder, External Limb Component
IQW
Hook, External Limb Component, Powered
IQX
Hook, External Limb Component, Mechanical
IQZ
Hand, External Limb Component, Powered
IRA
Hand, External Limb Component, Mechanical
IRD
Joint, Elbow, External Limb Component, Mechanical
IRE
Joint, Elbow, External Limb Component, Powered
ISH
Component, External, Limb, Ankle/Foot
ISL
Joint, Hip, External Limb Component
ISM
Pylon, Post Surgical
ISN
Cable
ISP
Valve, Prosthesis
ISR
Band Or Belt, Pelvic Support
ISS
Prosthesis, Thigh Socket, External Component
ISW
Assembly, Knee/Shank/Ankle/Foot, External
ISY
Joint, Knee, External Limb Component
ISZ
Unit, Wrist, External Limb Component, Mechanical
ITC
Stirrup, External Brace Component
ITG
Bandage, Cast
ITI
Wheelchair, Powered
ITJ
Walker, Mechanical
ITM
Cage, Knee
ITN
Splint, Denis Brown
ITO
Twister, Brace Setting
ITQ
Joint, Knee, External Brace
ITS
Joint, Hip, External Brace
ITW
Joint, Ankle, External Brace
KFT
Assembly, Shoulder/Elbow/Forearm/Wrist/Hand, Mechanical
KFW
Assembly, Shoulder/Elbow/Forearm/Wrist/Hand, Powered
KFX
Assembly, Thigh/Knee/Shank/Ankle/Foot, External
KGH
Unit, Wrist, External Limb Component, Powered
KHY
Cane, Safety Walk
KIC
Cushion, Flotation
KID
Restraint, Wheelchair, Non-Protective
KNN
Components, Wheelchair
KNO
Accessories, Wheelchair
KNP
Orthosis, Corrective Shoe
KTD
Orthosis, Abdominal
LBE
Stroller, Adaptive
LFF
Unit, Activation, Breath Control
MNE
Orthosis, Moldable, Supportive, Skin Protective
MRI
Orthosis, Truncal/Orthosis, Limb
NDA
Helmet, Cranial, For Protective Use
NHF
Monitor, Orthotic/Prosthetic
NJB
Orthosis, Truncal, For Dysmenorrhea
NXE
Walker, Mechanical, Poly Vinyl Chloride (Pvc)
OHI
Orthosis, Foot Drop
PAE
Upper Extremity Prosthesis With Multiple Simultaneous Degrees Of Freedom And Controlled Via Cutaneous Electromyography
PCE
Permanently Mounted Wheelchair Platform Lift
PMV
Orthosis, Limb, For Back Pain
QDT
Shoe With Adjustable Sole Units
Subpart E—Surgical Devices
Subpart F—Neurological Therapeutic Devices
Subpart F—Physical Medicine Therapeutic Devices
Radiology
General and Plastic Surgery
Toxicology
Medical Genetics
Unknown
PM
/
subpart-d—physical-medicine-prosthetic-devices
/
IPM
/
K770223
View Source
HEAVY FOAM HEEL & ELBOW PROTECTORS
Page Type
Cleared 510(K)
PDF
PDF
* The FDA doesn't provide PDFs for all submissions.
PDF
Analyzed PDF
510(k) Number
K770223
510(k) Type
Traditional
Applicant
ROBERT R. MOORE
Country
United States
FDA Decision
Substantially Equivalent
Decision Date
2/23/1977
Days to Decision
20 days