LDW · Fixative, Acid Containing

Pathology · 21 CFR 864.4010 · Class 1

Overview

Product CodeLDW
Device NameFixative, Acid Containing
Regulation21 CFR 864.4010
Device ClassClass 1
Review PanelPathology
GMP ExemptYes

Identification

A general purpose reagent is a chemical reagent that has general laboratory application, that is used to collect, prepare, and examine specimens from the human body for diagnostic purposes, and that is not labeled or otherwise intended for a specific diagnostic application. It may be either an individual substance, or multiple substances reformulated, which, when combined with or used in conjunction with an appropriate analyte specific reagent (ASR) and other general purpose reagents, is part of a diagnostic test procedure or system constituting a finished in vitro diagnostic (IVD) test. General purpose reagents are appropriate for combining with one or more than one ASR in producing such systems and include labware or disposable constituents of tests; but they do not include laboratory machinery, automated or powered systems. General purpose reagents include cytological preservatives, decalcifying reagents, fixative and adhesives, tissue processing reagents, isotonic solutions and pH buffers. Reagents used in tests for more than one individual chemical substance or ligand are general purpose reagents (e.g., Thermus aquaticus (TAQ) polymerase, substrates for enzyme immunoassay (EIA)).

Classification Rationale

Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter.

Recent Cleared Devices (4 of 4)

RecordDevice NameApplicantDecision DateDecision
K883062ATS SCHAUDINN'S FIXATIVE W/ACETIC ACIDAlpha-Tec Systems, Inc.Aug 4, 1988SESE
K842923PICRIC ACID 1% W/VE K Ind., Inc.Sep 11, 1984SESE
K842922PICRIC ACID SATURATED SOLUTIONE K Ind., Inc.Sep 7, 1984SESE
K831058SAF FIXATIVEAmerican Micro ScanJun 8, 1983SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...