21 CFR 864.4010 — Acid, Osmic

Pathology (PA) · Part 864 Subpart E—Specimen Preparation Reagents · § 864.4010

Identification

A general purpose reagent is a chemical reagent that has general laboratory application, that is used to collect, prepare, and examine specimens from the human body for diagnostic purposes, and that is not labeled or otherwise intended for a specific diagnostic application. It may be either an individual substance, or multiple substances reformulated, which, when combined with or used in conjunction with an appropriate analyte specific reagent (ASR) and other general purpose reagents, is part of a diagnostic test procedure or system constituting a finished in vitro diagnostic (IVD) test. General purpose reagents are appropriate for combining with one or more than one ASR in producing such systems and include labware or disposable constituents of tests; but they do not include laboratory machinery, automated or powered systems. General purpose reagents include cytological preservatives, decalcifying reagents, fixative and adhesives, tissue processing reagents, isotonic solutions and pH buffers. Reagents used in tests for more than one individual chemical substance or ligand are general purpose reagents (e.g., Thermus aquaticus (TAQ) polymerase, substrates for enzyme immunoassay (EIA)).

Classification Rationale

Class I (general controls). The device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 864.9. If the device is not labeled or otherwise represented as sterile, it is exempt from the current good manufacturing practice requirements of the quality management system regulation in part 820 of this chapter, except for requirements concerning records and complaint files under § 820.35 of this chapter.

Product Codes

Product CodeDevice NameClassDevicesAttributes
HZIAcid, Osmic10
IALIodine (Tincture)10
IAMSolution, Lugol'S10
IATSyrup, Gum, Apathy'S10
IAWCollodion10
IAYColchicine10
IBBPhytohemaglutinin M10
IERPolyethylene Glycol (Carbowax)11
IEXGelatin10
IEZCelloidin10
IFFSolution, Decalcifier, Electrolytic10
IFHSolution, Zenker'S12
IFISprays, Synthetic, Smear11
IFJFixative, Richardson Glycol10
IFLPolyethylene Glycol Preservative10
IFNSolution, Orth'S10
IFOSolution, Newcomer'S10
IFPFormalin, Neutral Buffered115
IFQFormulations, Mercuric Chloride For Tissue12
IFSSolution, Helly10
IFTGlutaraldehyde11
IFYGelatin-Formalin10
IFZGelatin For Specimen Adhesion11
IGBSolution, Formalin-Sodium Acetate11
IGCFormalin-Saline12
IGDSolution, Formol Calcium10
IGESolution, Formalin Ammonium Bromide12
IGFSolution, Formalin-Alcohol-Acetic Acid11
IGGFormaldehyde (Formalin, Formol)17
IGKSolution, Clarke'S10
IGMSolution, Carnoy'S13
IGNFluid, Bouin'S12
IJZOil, Clearing11
JCBDetergent10
JCCPh Buffer17
JCESolution, Isotonic17
KDXSolution, Decalcifier, Acid Containing18
KDYAgent, Chelating For Decalcification10
KEEOsmium Tetroxide10
KEFParaformaldehyde10
KELAdhesive, Albumin-Based12
KEMAgent, Clearing115
KEOFormulations, Paraffin, All111
KEPMedia, Mounting, Oil Soluble13
KEQMedia, Mounting, Water Soluble17
LDWFixative, Acid Containing14
LDXFixative, Metallic Containing11
LDYFixative, Formalin-Containing11
LDZFixative, Alcohol Containing18
LEAPreservative, Cytological14
LEBMounting Media15
PPMGeneral Purpose Reagent116
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...