PRIME MODULAR ENDO HEAD
Device Facts
| Record ID | K962646 |
|---|---|
| Device Name | PRIME MODULAR ENDO HEAD |
| Applicant | Orthopaedic Innovations, Inc. |
| Product Code | KWL · Orthopedic |
| Decision Date | Sep 23, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3360 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Intended Use
The Prime Modular Endo Heads, with the Prime Cemented Femoral Stems, are intended to replace the femoral head in cases of femoral head and neck fracture, nonunion of femoral head and neck fractures, femoral head aseptic necrosis, osteoarthritis, rheumatoid arthritis and revision of failed hip fracture treatment.
Device Story
Modular endoprosthetic device; one-piece spherical head with Morse-type taper; attaches to Prime Cemented Calcar Femoral Stems. Used in orthopedic surgery to replace femoral head. Provides modular component selection for surgeons. Benefits patient by restoring hip joint function in cases of fracture, necrosis, or arthritis.
Clinical Evidence
Bench testing only.
Technological Characteristics
Material: Cobalt-Chrome Alloy (ASTM F-1537). Design: Spherical head with Morse-type taper. Dimensions: 36mm to 70mm diameter in 1mm increments. Sterilization: Presterile.
Indications for Use
Indicated for patients requiring femoral head replacement due to femoral head/neck fracture, nonunion of fractures, aseptic necrosis, osteoarthritis, rheumatoid arthritis, or revision of failed hip fracture treatment.
Regulatory Classification
Identification
A hip joint femoral (hemi-hip) metallic cemented or uncemented prosthesis is a device intended to be implanted to replace a portion of the hip joint. This generic type of device includes prostheses that have a femoral component made of alloys, such as cobalt-chromium-molybdenum. This generic type of device includes designs which are intended to be fixed to the bone with bone cement (§ 888.3027) as well as designs which have large window-like holes in the stem of the device and which are intended for use without bone cement. However, in these latter designs, fixation of the device is not achieved by means of bone ingrowth.
Predicate Devices
- Hemi-Head by Orthomet
- Modular Cathcart Endoprosthesis System by DePuy
- Unipolar Head by Smith and Nephew Richards
Related Devices
- K150576 — TGM Biolox delta Ceramic Heads · Tgm Medical, Inc. · Sep 9, 2015
- K010081 — ACUMATCH L-SERIES UNIPOLAR ENDOPROSTHESIS · Exactech, Inc. · Feb 5, 2001
- K201047 — Fusion Taper System · Signature Orthopaedics Pty, Ltd. · Apr 16, 2021
- K110245 — UNITED UTF STEM · United Orthopedic Corporation · Aug 4, 2011
- K042091 — BIOLOX DELTA CERAMIC HEADS · Biomet, Inc. · Mar 25, 2005