OMEGA+ COMPRESSION SCREW SYSTEM
Device Facts
| Record ID | K955306 |
|---|---|
| Device Name | OMEGA+ COMPRESSION SCREW SYSTEM |
| Applicant | Howmedica Corp. |
| Product Code | KTT · Orthopedic |
| Decision Date | Apr 10, 1996 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 888.3030 |
| Device Class | Class 2 |
| Attributes | Therapeutic |
Indications for Use
The Omega+ Compression Screw System consists of a series of lag screws, proximal hip sideplates, supracondylar side plates, and a compression screw designed to be used in the temporary stabilization of fractures of the proximal femur (intracapsular or intertrochanteric), and/or distal third of the femur (supracondylar area).
Device Story
Metallic bone fixation system; includes lag screws, proximal hip sideplates, supracondylar side plates, and compression screw. Used for temporary stabilization of proximal and distal femoral fractures. Components previously cleared; current submission introduces sterile packaging option. Intended for use by orthopedic surgeons in clinical/surgical settings. No changes to design, materials, manufacturing, or surgical technique.
Clinical Evidence
Bench testing only; no clinical data provided. Equivalence established via comparison to previously cleared predicate devices.
Technological Characteristics
Metallic bone fixation appliances; components include lag screws, sideplates, and compression screws. No changes to materials or design from predicate devices. Sterilization provided via validated technique for sterile packaging option.
Indications for Use
Indicated for temporary stabilization of fractures of the proximal femur (intracapsular or intertrochanteric) and/or distal third of the femur (supracondylar area).
Regulatory Classification
Identification
Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.