QHE · Shoulder Arthroplasty Implantation System

Orthopedic · 21 CFR 888.3660 · Class 2

Overview

Product CodeQHE
Device NameShoulder Arthroplasty Implantation System
Regulation21 CFR 888.3660
Device ClassClass 2
Review PanelOrthopedic

Identification

A shoulder joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace a shoulder joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across-the-joint. This generic type of device includes prostheses that have a humeral resurfacing component made of alloys, such as cobalt-chromium-molybdenum, and a glenoid resurfacing component made of ultra-high molecular weight polyethylene, and is limited to those prostheses intended for use with bone cement (§ 888.3027).

Classification Rationale

Class II. The special controls for this device are:

Special Controls

*Classification.* Class II. The special controls for this device are:(1) FDA's: (i) “Use of International Standard ISO 10993 ‘Biological Evaluation of Medical Devices—Part I: Evaluation and Testing,’ ” (ii) “510(k) Sterility Review Guidance of 2/12/90 (K90-1),” (iii) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone Cement,” (iv) “Guidance Document for the Preparation of Premarket Notification (510(k)) Application for Orthopedic Devices,” and (v) “Guidance Document for Testing Non-articulating, ‘Mechanically Locked’ Modular Implant Components,” (2) International Organization for Standardization's (ISO): (i) ISO 5832-3:1996 “Implants for Surgery—Metallic Materials—Part 3: Wrought Titanium 6-aluminum 4-vandium Alloy,” (ii) ISO 5832-4:1996 “Implants for Surgery—Metallic Materials—Part 4: Cobalt-chromium-molybdenum casting alloy,” (iii) ISO 5832-12:1996 “Implants for Surgery—Metallic Materials—Part 12: Wrought Cobalt-chromium-molybdenum alloy,” (iv) ISO 5833:1992 “Implants for Surgery—Acrylic Resin Cements,” (v) ISO 5834-2:1998 “Implants for Surgery—Ultra-high Molecular Weight Polyethylene—Part 2: Moulded Forms,” (vi) ISO 6018:1987 “Orthopaedic Implants—General Requirements for Marking, Packaging, and Labeling,” and (vii) ISO 9001:1994 “Quality Systems—Model for Quality Assurance in Design/Development, Production, Installation, and Servicing,” and (3) American Society for Testing and Materials': (i) F 75-92 “Specification for Cast Cobalt-28 Chromium-6 Molybdenum Alloy for Surgical Implant Material,” (ii) F 648-98 “Specification for Ultra-High-Molecular-Weight Polyethylene Powder and Fabricated Form for Surgical Implants,” (iii) F 799-96 “Specification for Cobalt-28 Chromium-6 Molybdenum Alloy Forgings for Surgical Implants,” (iv) F 1044-95 “Test Method for Shear Testing of Porous Metal Coatings,” (v) F 1108-97 “Specification for Titanium-6 Aluminum-4 Vanadium Alloy Castings for Surgical Implants,” (vi) F 1147-95 “Test Method for Tension Testing of Porous Metal,” (vii) F 1378-97 “Standard Specification for Shoulder Prosthesis,” and (viii) F 1537-94 “Specification for Wrought Cobalt-28 Chromium-6 Molybdenum Alloy for Surgical Implants.”

Recent Cleared Devices (20 of 26)

Showing 20 most recent of 26 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K260802Materialise Shoulder System™, Materialise Shoulder Guide and Models, SurgiCase Shoulder PlannerMaterialise NVJun 9, 2026SESE
K261510Signature™ ONE SystemOrthosoft Inc. (d/b/a) Zimmer CASJun 4, 2026SESE
K260104Signature™ ONE SystemOrthosoft Inc. (d/b/a) Zimmer CASFeb 4, 2026SESE
K251558Precision AI Surgical Planning System (PAI-SPS)Precision AI Pty, Ltd.Jan 12, 2026SESE
K243509Archer PSI System3D-SideMay 12, 2025SESE
K241470CORE Shoulder SystemLinkBio Corp.Feb 20, 2025SESE
K243955Precision AI Surgical Planning System (PAI-SPS)Precision AI Pty, Ltd.Jan 21, 2025SESE
K242813Materialise Shoulder System™, Materialise Shoulder Guide and Models, SurgiCase Shoulder PlannerMaterialise NVOct 18, 2024SESE
K241097Arthrex Virtual Implant Positioning (VIP) System SoftwareArthrex, Inc.Oct 2, 2024SESE
K233992Precision AI Surgical Planning System (PAI-SPS)Precision AI Pty, Ltd.Aug 5, 2024SESE
K241143Materialise Shoulder System™, Materialise Shoulder Guide and Models, SurgiCase Shoulder PlannerMaterialise NVMay 22, 2024SESE
K232425Signature™ ONE SystemOrthosoft Inc. (D/B/A) Zimmer Cas)Dec 12, 2023SESE
K233408Materialise Shoulder System™, Materialise Shoulder Guide and Models, SurgiCase Shoulder PlannerMaterialise NVNov 9, 2023SESE
K231112Materialise Shoulder System™, Materialise Shoulder Guide and Models, SurgiCase Shoulder PlannerMaterialise NVSep 12, 2023SESE
K230904Arthrex Virtual Implant Positioning (VIP) SystemArthrex, Inc.Jun 22, 2023SESE
K222007Arthrex Virtual Implant Positioning (VIP) SystemArthrex, Inc.Mar 8, 2023SESE
K230315Materialise Shoulder System™ Materialise Shoulder Guide and Models SurgiCase Shoulder PlannerMaterialise NVMar 6, 2023SESE
K222405Smart SPACE Shoulder Planner and 3D PositionersLima Corporate S.P.A.Dec 20, 2022SESE
K220452Materialise Shoulder SystemTM Materialise Shoulder Guide and Models SurgiCase Shoulder PlannerMaterialise NVAug 17, 2022SESE
K212569Materialise Shoulder System™, Materialise Shoulder Guide and Models, SurgiCase Shoulder PlannerMaterialise NVJan 12, 2022SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...