OQG · Hip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented

Orthopedic · 21 CFR 888.3358 · Class 2

Overview

Product CodeOQG
Device NameHip Prosthesis, Semi-Constrained, Cemented, Metal/Polymer, + Additive, Porous, Uncemented
Regulation21 CFR 888.3358
Device ClassClass 2
Review PanelOrthopedic
ImplantYes

Identification

A hip joint metal/polymer/metal semi-constrained porous-coated uncemented prosthesis is a device intended to be implanted to replace a hip joint. The device limits translation and rotation in one or more planes via the geometry of its articulating surfaces. It has no linkage across the joint. This generic type of device has a femoral component made of a cobalt-chromium-molybdenum (Co-Cr-Mo) alloy or a titanium-aluminum-vanadium (Ti-6Al-4V) alloy and an acetabular component composed of an ultra-high molecular weight polyethylene articulating bearing surface fixed in a metal shell made of Co-Cr-Mo or Ti-6Al-4V. The femoral stem and acetabular shell have a porous coating made of, in the case of Co-Cr-Mo substrates, beads of the same alloy, and in the case of Ti-6Al-4V substrates, fibers of commercially pure titanium or Ti-6Al-4V alloy. The porous coating has a volume porosity between 30 and 70 percent, an average pore size between 100 and 1,000 microns, interconnecting porosity, and a porous coating thickness between 500 and 1,500 microns. The generic type of device has a design to achieve biological fixation to bone without the use of bone cement.

Classification Rationale

Class II.

Recent Cleared Devices (20 of 20)

RecordDevice NameApplicantDecision DateDecision
K202705Prime and DYNASTY® Additive Manufacturing ShellsMicroport Orthopedics, Inc.Aug 20, 2021SESE
K203472KMTI Hip Replacement SystemKyocera Medical Technologies, Inc.Apr 2, 2021SESE
K201660KMTI Hip Replacement System, Tesera Trabecular Technologies (T3) Acetabular Shell System, Porous Acetabular Cup SystemKyocera Medical Technologies, Inc.Jul 16, 2020SESE
K200328Tesera Trabecular Technologies (T3) Acetabular Shell System, Porous Acetabular Cup SystemKyocera Medical Technologies, Inc.Mar 11, 2020SESE
K172651FMP Extended LinersEncore Medical L.P.Dec 13, 2017SESE
K171543Renovis Surgical Hip Replacement SystemRenovis Surgical TechnologiesNov 16, 2017SESE
K173104Klassic HD® Hooded Acetabular Insert with E-Link® Poly, Klassic HD® Low Profile Acetabular Insert with E-Link® PolyTotal Joint Orthopedics, Inc.Oct 27, 2017SESE
K143647Renovis Surgical Hip Replacement SystemRenovis Surgical Technologies, Inc.May 11, 2015SESE
K140130X-ALT HIGHLY CROSS LINKED ACETABULAR LINERS WITH VITAMIN E, NEUTRAL, 10 DEGREE HOODED, 20 DEGREE HOODEDEncore Medical L.P.Nov 6, 2014SESE
K141972KLASSIC HD ACETABULAR INSERT WITH E-LINK POLYTotal Joint Orthopedics, Inc.Oct 9, 2014SESE
K140701NOVOHIP BIPOLAR HEAD/NOVOHIP VITAMIN E LINER/ BONE SCREWS/ HOLE PLUGNovosource, Inc.Jun 27, 2014SESE
K130652VITALITE E CROSS-LINKED POLYETHYLENE ACETABULAR INSERTConsensus Orthopedics, Inc.Dec 17, 2013SESE
K122783PLASMAFIT ACETABULAR CUP AND VITELENE INSERTAesculap Implant System, Inc.Oct 30, 2013SESE
K130365X-ALT HIGHLY CROSS LINKED VE ACETABULAR LINEREncore Medical L.P.Sep 23, 2013SESE
K122158PBP TOTAL HIP SYSTEMPipeline Biomedical Products, LLCDec 11, 2012SESE
K122773CROSS-OVER ACETABULAR SHELL & LINERStelkast CompanyOct 9, 2012SESE
K112897RENOVIS SURGICAL HIP JOINT REPLACEMENT PROSTHESISRenovis Surgical Technologies, LLCJun 13, 2012SESE
K120370VIVACIT-E VITAMIN E HIGHLY CROSSLINKED POLYETHYLENE LINERSZimmer, Inc.Jun 4, 2012SESE
K112802PIPELINE TOTAL HIP SYSTEMPipeline OrthopedicsMar 9, 2012SESE
K094035EXP ACETABULAR LINER, MODELS SC3342 NON-HOODED 28MM, SC3343 HOODED 28MMStelkast CompanyMar 24, 2011SESE

Top Applicants

Innolitics

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...