HOWMEDICA MAINSTAY ANCHOR

K965175 · Howmedica Corp. · JDR · Mar 13, 1997 · Orthopedic

Device Facts

Record IDK965175
Device NameHOWMEDICA MAINSTAY ANCHOR
ApplicantHowmedica Corp.
Product CodeJDR · Orthopedic
Decision DateMar 13, 1997
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3030
Device ClassClass 2
AttributesTherapeutic

Intended Use

The Howmedica Mainstay™ Soft Tissue Anchor is a titanium alloy self-drilling, self-tapping cancellous screw threaded device for the attachment of soft tissue to bone. The device is available in three sizes and has a proximal thru-hole for the attachment of the desired suture material. The purpose of the device is to hold, with sutures, the soft tissue against the bone for a prescribed healing period. This device is to be used for soft tissue attachment in the shoulder, ankle, foot, wrist, hand, elbow, knee and pelvis.

Device Story

Titanium alloy self-drilling, self-tapping cancellous screw; proximal thru-hole for suture attachment; used by surgeons to secure soft tissue to bone in various orthopedic sites; holds tissue against bone during healing; provides initial fixation strength.

Clinical Evidence

Bench testing only; performed per FDA 'Bone Anchor Devices: Guidance for Testing - April 20, 1996'. Results show initial fixation strength not significantly different from Mitek SuperAnchor.

Technological Characteristics

Titanium alloy; self-drilling, self-tapping cancellous screw design; three sizes; proximal thru-hole for suture.

Indications for Use

Indicated for soft tissue attachment to bone in shoulder, ankle, foot, wrist, hand, elbow, knee, and pelvis, including soft tissue reconstruction following total hip arthroplasty.

Regulatory Classification

Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Reference Devices

Related Devices

Submission Summary (Full Text)

{0} K965175 510(k) Summary MAR 13 1997 Device: Howmedica Mainstay™ Soft Tissue Anchor The Howmedica Mainstay™ Soft Tissue Anchor is a titanium alloy self-drilling, self-tapping cancellous screw threaded device for the attachment of soft tissue to bone. The device is available in three sizes and has a proximal thru-hole for the attachment of the desired suture material. The purpose of the device is to hold, with sutures, the soft tissue against the bone for a prescribed healing period. This device is to be used for soft tissue attachment in the shoulder, ankle, foot, wrist, hand, elbow, knee and pelvis. The 510(k) for this device K953531 was determined to be substantially equivalent on September 26, 1995. This present submission is being made to introduce an additional indication for use in soft tissue reconstruction following total hip arthroplasty. Testing was performed in accordance with that described in the FDA "Bone Anchor Devices: Guidance for Testing - April 20, 1996." Results of this testing indicated that the initial fixation strength of the Mainstay™ Soft Tissue Anchor did not differ significantly from that of the Mitek SuperAnchor when used in the same anatomic site. For information contact: John Dichiara Manager, Regulatory Affairs Howmedica Inc. 359 Veterans Boulevard Rutherford, NJ 07070 (201) 507-7386 Fax: (201) 507-6870
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...