ARCAD COMPRESSIVE OSTEOSYNTHESIS STAPLE, EXPRESS COMPRESSIVE OSTEOSYNTHESIS STAPLE

K142111 · Novatsep · JDR · Dec 19, 2014 · Orthopedic

Device Facts

Record IDK142111
Device NameARCAD COMPRESSIVE OSTEOSYNTHESIS STAPLE, EXPRESS COMPRESSIVE OSTEOSYNTHESIS STAPLE
ApplicantNovatsep
Product CodeJDR · Orthopedic
Decision DateDec 19, 2014
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3030
Device ClassClass 2
AttributesTherapeutic

Intended Use

The compressive osteosynthesis staples are intended for hand and foot bone fragments osteotomy fixation and joint arthrodesis.

Device Story

ARCAD and EXPRESS compressive osteosynthesis staples are single-use, bipodal bone fixation implants; manufactured from shape memory nickel-titanium alloy. Intended for permanent implantation in hand and foot surgery to stabilize bone fragments following osteotomy or to facilitate joint arthrodesis. Staples function via shape memory properties to provide compressive force across the bone site. Used by surgeons in clinical settings. Benefit includes stable fixation of bone segments to promote healing.

Clinical Evidence

No clinical data or animal studies were required for this submission. Substantial equivalence is supported by bench testing, including biocompatibility evaluation per ISO 10993 and mechanical testing (static bending, dynamic bending, pull-out resistance) per ASTM F564-10.

Technological Characteristics

Material: Wrought Nickel-Titanium shape memory alloy (ASTM F2063-12). Design: Bipodal compression staple. Mechanical testing per ASTM F564-10 (static/dynamic bending, pull-out resistance). Single-use, permanently implanted.

Indications for Use

Indicated for hand and foot bone fragments osteotomy fixation and joint arthrodesis.

Regulatory Classification

Identification

Single/multiple component metallic bone fixation appliances and accessories are devices intended to be implanted consisting of one or more metallic components and their metallic fasteners. The devices contain a plate, a nail/plate combination, or a blade/plate combination that are made of alloys, such as cobalt-chromium-molybdenum, stainless steel, and titanium, that are intended to be held in position with fasteners, such as screws and nails, or bolts, nuts, and washers. These devices are used for fixation of fractures of the proximal or distal end of long bones, such as intracapsular, intertrochanteric, intercervical, supracondylar, or condylar fractures of the femur; for fusion of a joint; or for surgical procedures that involve cutting a bone. The devices may be implanted or attached through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ Image /page/0/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a circular seal with the text "DEPARTMENT OF HEALTH & HUMAN SERVICES - USA" around the perimeter. Inside the seal is a stylized image of three human profiles facing to the right, with flowing lines extending from the profiles. December 19, 2014 Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 Novatsep % Mr. Gilles Audic QA/RA Director Espace Performance Alphasis-Batiment C1-C2 Saint Gregoire, 35769 France Re: K142111 Trade/Device Name: ARCAD Compressive Osteosynthesis Staple, EXPRESS Compressive Osteosynthesis Staple Regulation Number: 21 CFR 888.3030 Regulation Name: Single/multiple component metallic bone fixation appliances and accessories Regulatory Class: Class II Product Code: JDR Dated: November 17, 2014 Received: November 21, 2014 Dear Mr. Audic: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food. Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice, labeling, and prohibitions against misbranding and adulteration. Please note: CDRH does not evaluate information related to contract liability warranties. We remind you, however, that device labeling must be truthful and not misleading. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); medical device reporting (reporting of medical device {1}------------------------------------------------ related adverse events) (21 CFR 803); good manufacturing practice requirements as set forth in the quality systems (QS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21 CFR Part 807.97). For questions regarding the reporting of adverse events under the MDR regulation (21 CFR Part 803), please go to http://www.fda.gov/MedicalDevices/Safety/ReportaProblem/default.htm for the CDRH's Office of Surveillance and Biometrics/Division of Postmarket Surveillance. You may obtain other general information on your responsibilities under the Act from the Division of Industry and Consumer Education at its toll-free number (800) 638-2041 or (301) 796-7100 or at its Internet address http://www.fda.gov/MedicalDevices/ResourcesforYou/Industry/default.htm. Sincerely yours, # Mark N. Melkerson -S Mark N. Melkerson Director Division of Orthopedic Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {2}------------------------------------------------ # Indications for Use 510(k) Number (if known) K142111 #### Device Name ARCAD Compressive osteosynthesis staple EXPRESS Compressive osteosynthesis staple #### Indications for Use (Describe) The compressive osteosynthesis staples are indicated for hand and foot bone fragments osteotomy fixation and joint arthrodesis. Type of Use (Select one or both, as applicable) > Prescription Use (Part 21 CFR 801 Subpart D) _ Over-The-Counter Use (21 CFR 801 Subpart C) ## PLEASE DO NOT WRITE BELOW THIS LINE - CONTINUE ON A SEPARATE PAGE IF NEEDED. ### FOR FDA USE ONLY Concurrence of Center for Devices and Radiological Health (CDRH) (Signature) This section applies only to requirements of the Paperwork Reduction Act of 1995. ### *DO NOT SEND YOUR COMPLETED FORM TO THE PRA STAFF EMAIL ADDRESS BELOW.* The burden time for this collection of information is estimated to average 79 hours per response, including the time to review instructions, search existing data sources, gather and maintain the data needed and complete and review the collection of information. Send comments regarding this burden estimate or any other aspect of this information collection, including suggestions for reducing this burden, to: > Department of Health and Human Services Food and Drug Administration Office of Chief Information Officer Paperwork Reduction Act (PRA) Staff PRAStaff(@fda.hhs.gov "An agency may not conduct or sponsor, and a person is not required to respond to, a collection of information unless it displays a currently valid OMB number." {3}------------------------------------------------ # "510(k) Summary" as required by section 807.92(c) | Submitter | NOVASTEP | |------------------|-----------------------------------------| | | Espace performance Alphasis | | | Bâtiment C1-C2 | | | 35769 SAINT GREGOIRE | | | France | | | Phone : + 33 (0)2 99 33 86 50 | | | Fax :+ 33 (0)9 70 29 18 95 | | Contact person | Mister Gilles AUDIC | | | QA / RA Director | | | Cell phone:+33 (0)6 30 93 96 08 | | | e-mail: gilles.audic@novastep-ortho.com | | Preparation date | 17th November, 2014 | | Trade name | ARCAD compressive osteosynthesis staple<br>EXPRESS compressive osteosynthesis staple | |---------------------|-------------------------------------------------------------------------------------------------------------------| | Common Name | Staple, Fixation, Bone | | Classification Name | Single/multiple component metallic bone fixation appliances and<br>accessories (21CFR 888.3030, product code JDR) | | Regulatory class | II | | Legally marketed<br>predicate devices | 510(k) number: K122113<br>Device name: memory metal staples, Easyclip<br>Original applicant: STRYKER corp. | |------------------------------------------------------------------------------------|---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------| | Description | Compressive osteosynthesis staples are single-use bone fixation<br>appliances intended to be permanently implanted. ARCAD osteosynthesis<br>staples are bipodal compression staples made of shape memory nickel<br>titanium alloy. | | | | | Intended use | The compressive osteosynthesis staples are intended for hand and foot<br>bone fragments osteotomy fixation and joint arthrodesis. | | Comparison of the<br>technological<br>characteristics with the<br>predicate device | The new devices compressive osteosynthesis staples have similar<br>technological characteristics in terms of material (ASTM F2063-12<br>Standard Specification for Wrought Nickel-Titanium Shape Memory<br>Alloys for Medical Devices and Surgical Implants) and mechanical<br>characteristics (ASTM F564-10 Sections A1, A2 and A4 Standard<br>Specification and Test Methods for Metallic Bone Staples) and thus are<br>believed to be substantially equivalent to the predicate STRYKER corp.<br> | | Performance data | The biocompatibility evaluation for new devices compressive<br>osteosynthesis staples was conducted in accordance with Blue Book<br>Memorandum #G95-1 (Use of International Standard ISO-10993,<br>Biological Evaluation of Medical Devices Part 1: Evaluation and Testing)<br>and International Standard ISO 10993-1 (Biological Evaluation of Medical<br>Devices - Part 1: Evaluation and Testing Within a Risk Management<br>Process) as recognized by FDA.<br><br>The new devices compressive osteosynthesis staples have similar<br>technological characteristics in terms of design and mechanical<br>characteristics (static bending, dynamic bending and pull-out resistance)<br>and thus are believed to be substantially equivalent to the predicate<br>STRYKER corp. memory metal staples, Easyclip (K122113). | | Indication for use | The compressive osteosynthesis staples are indicated for hand and foot<br>bone fragments osteotomy fixation and joint arthrodesis. | | Clinical studies | Clinical studies were not required for this submission. | | Animal studies | Animal studies were not required for this submission. | | Conclusion | The compressive osteosynthesis staples are substantially equivalent to<br>their predicate devices STRYKER corp. memory metal staples, Easyclip<br>(K122113) in terms of intended use and indications for use, material,<br>design and function. Any minor differences between these two devices<br>do not raise new questions of safety and effectiveness. | {4}------------------------------------------------
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...