DALL-MILES TROCHANTER CABLE SUPERGRIP

K962162 · Howmedica Corp. · JDQ · Aug 14, 1996 · Orthopedic

Device Facts

Record IDK962162
Device NameDALL-MILES TROCHANTER CABLE SUPERGRIP
ApplicantHowmedica Corp.
Product CodeJDQ · Orthopedic
Decision DateAug 14, 1996
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3010
Device ClassClass 2
AttributesTherapeutic

Intended Use

The Grip component provides for trochanteric reattachment following osteotomy in Total Hip Arthroplasty. The proximal hooks of the Grip are placed over the top of the trochanter and secured by passing Dall-Miles cables through the holes and crimping them in place.

Device Story

Bone fixation cerclage system; used for trochanteric reattachment post-osteotomy in total hip arthroplasty. Device consists of a grip component with proximal hooks and cables. Hooks placed over trochanter; cables passed through grip holes and crimped to secure. Modification reduces cable exit angle to minimize stress concentrations. Used by orthopedic surgeons in clinical/OR settings.

Clinical Evidence

Bench testing only.

Technological Characteristics

Bone fixation cerclage; metallic grip component with cable-based tensioning and crimping mechanism. Design modification reduces cable exit angle to mitigate stress concentrations. Sterilization and material specifications not explicitly detailed in summary.

Indications for Use

Indicated for trochanteric reattachment following osteotomy in Total Hip Arthroplasty.

Regulatory Classification

Identification

A bone fixation cerclage is a device intended to be implanted that is made of alloys, such as cobalt-chromium-molybdenum, and that consists of a metallic ribbon or flat sheet or a wire. The device is wrapped around the shaft of a long bone, anchored to the bone with wire or screws, and used in the fixation of fractures.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0} AUG 14 1996 K96 216 2 510(k) Summary Proprietary Name: Dall-Miles Trochanter Cable SuperGrip Common Name: Bone Fixation Cerclage Classification Name and Reference: Bone Fixation Cerclage 21 CFR 888.3010 Proposed Regulatory Class: Class II Device Product Code: OR(87) JDQ For information contact: Frank Maas Manager, Regulatory Affairs Howmedica Inc. 359 Veterans Boulevard Rutherford, NJ 07070 Telephone: (201) 507-7875 Fax: (201) 507-6870 Date Summary Prepared: 6/3/96 The Dall-Miles Trochanter Cable Grip described in this submission is a modification of the original Dall-Miles Cable Grip cleared in (K 872224). The Grip component provides for trochanteric reattachment following osteotomy in Total Hip Arthroplasty. The proximal hooks of the Grip are placed over the top of the trochanter and secured by passing Dall-Miles cables through the holes and crimping them in place. The modification to the Grip reduces the angle that the cable exits the Grip, thereby relieving potential stress concentrations in the cable. The substantial equivalence of the Dall-Miles Trochanter Cable Grip is based on the equivalence in intended use, materials, design, operational principles, and indications and contraindications to Howmedica's original Dall-Miles Cable Grip System (K 872224 and K 900926) and Biomet Medical Products' BMP Cable System.
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...