ORTHOPRO STEINMAN PINS AND KIRSCHNER WIRES

K070555 · Orthopro, LLC · HTY · Jul 13, 2007 · Orthopedic

Device Facts

Record IDK070555
Device NameORTHOPRO STEINMAN PINS AND KIRSCHNER WIRES
ApplicantOrthopro, LLC
Product CodeHTY · Orthopedic
Decision DateJul 13, 2007
DecisionSESE
Submission TypeTraditional
Regulation21 CFR 888.3040
Device ClassClass 2
AttributesTherapeutic

Intended Use

The OrthoPro Steinman Pins and Kirschner Wires are indicated for use in fixation of bone fractures, for bone reconstructions, as guide pins for insertion of other implants or implantation through the skin so that traction may be applied to the skeletal system.

Device Story

OrthoPro Steinman Pins and Kirschner Wires are metallic bone fixation fasteners used in orthopedic procedures. Devices are available in various lengths (4-12 inches), diameters (0.028-0.1875 inches), and tip styles (trocar, diamond, cove, check, round). Pins/wires are provided non-sterile for single-use. They are manually implanted by surgeons to stabilize bone fractures, reconstruct bone, guide other implants, or provide skeletal traction. No electronic, software, or algorithmic components are involved.

Clinical Evidence

No clinical data. Bench testing only, consisting of material and dimensional verification to confirm equivalence to predicate devices.

Technological Characteristics

Constructed of 316LVM surgical implant grade stainless steel per ASTM F138. Mechanical fixation device. Dimensions: 0.028 to 0.1875 inch diameter; 4 to 12 inch length. Available in smooth, partially threaded, or fully threaded configurations with various distal/proximal tip styles. Non-sterile, single-use.

Indications for Use

Indicated for bone fracture fixation, bone reconstruction, use as guide pins for other implants, or percutaneous implantation for skeletal traction.

Regulatory Classification

Identification

A smooth or threaded metallic bone fixation fastener is a device intended to be implanted that consists of a stiff wire segment or rod made of alloys, such as cobalt-chromium-molybdenum and stainless steel, and that may be smooth on the outside, fully or partially threaded, straight or U-shaped; and may be either blunt pointed, sharp pointed, or have a formed, slotted head on the end. It may be used for fixation of bone fractures, for bone reconstructions, as a guide pin for insertion of other implants, or it may be implanted through the skin so that a pulling force (traction) may be applied to the skeletal system.

Predicate Devices

Related Devices

Submission Summary (Full Text)

{0}------------------------------------------------ K07055 JUL 1 3 2007 ### 510(k) Summary July 12th, 2007 This safety and effectiveness summary for the OrthoPro Steinman Pins and Kirschner Wires is provided as required per section 513(i)(3) of the Food, Drug, and Cosmetic Act. 510(k) Owner: OrthoPro LLC. 3450 S. Highland Dr. #303 Salt Lake City, UT 84106 Telephone: 801-746-0208 Authorized Contact Person: Christopher L. Cook Straits Orthopaedics Inc. 13115 NE 4th St. Suite 130 Vancouver, WA 98684 Telephone: 360-253-9761 | Trade Name: | OrthoPro Steinman Pins and Kirschner Wires | |----------------------|----------------------------------------------------------| | Common Name: | Steinman Pins<br>Kirschner Wires | | Classification Name: | Smooth or threaded metallic bone fixation fastener | | Classification: | 888.3040 | | Product Class: | II | | Product Code: | HTY pin, fixation, smooth<br>IDW pin, fixation, threaded | Predicate or legally marketed devices which are substantially equivalent: | Product | 510k Number | |----------------------------------------|---------------| | DePuy Steinman Pins and Kirshner Wires | K960385 | | Smith and Nephew Pins and Wires | K994143 | | Smith and Nephew Pins and Wires | Pre-amendment | ### Device Description The OrthoPro Steinman Pins and Kirschner Wires are offered in a variety of lengths, diameters, tip styles, and threading. These devices are constructed of implant grade 316LVM stainless steel conformant to ASTM F138, are provided non-sterile, and are intended for single-use only OrthoPro Steinman Pins and Kirschner Wires 510(k) Submission Page 5 of 11 {1}------------------------------------------------ ### Intended Use The OrthoPro Steinman Pins and Kirschner Wires are indicated for use in fixation of bone fractures, for bone reconstructions, as guide pins for insertion of other implants or implantation through the skin so that traction may be applied to the skeletal system. ## Comparison of the technological characteristics of the device to predicate and legally marketed devices The proposed devices are substantially equivalent to the identified predicate device in materials of construction, physical characteristics, and intended use. ### Summary of Non-Clinical Tests The non-clinical testing to be conducted on the OrthoPro Steinman Pins and Kirschner Wires will include material and dimensional verification. The OrthoPro Steinman Pins and Kirschner Wires are equivalent in physical dimensions and materials to the identified predicate devices. Testing, therefore, is not needed to demonstrate that the subject devices are substantially equivalent to the legally marketed predicate devices. Contact: CTCK Christopher L. Cook Authorized Contact Person Vice President Regulatory Affairs Straits Orthopaedics Inc. OrthoPro Steinman Pins and Kirschner Wires 510(k) Submission Page 6 of 11 {2}------------------------------------------------ | 2.7 Classification: | 888.3040 | |---------------------|----------------------------------------------------------| | 2.8 Panel | Orthopedic | | 2.9 Product Class: | II | | Product Code | HTY pin, fixation, smooth<br>JDW pin, fixation, threaded | ### 2.1.1 Predicate Devices | Product | 510k Number | |-----------------------------------------|---------------| | DePuy Steinman Pins and Kirschner Wires | K960385 | | Smith and Nephew Pins and Wires | K994143 | | Smith and Nephew Pins and Wires | Pre-amendment | #### 3.0 Device Description 2.1.0 The OrthoPro Pins and Wires product family is available in a range of lengths, diameters, and tip styles, with and without threading. - 3.1 Materials of Construction All pins and wires are manufactured from 316LVM surgical implant grade stainless steel certified to ASTM F138. - 3.2 Diameter The devices will range in diameter from 0.028 inches to 0.1875 inches. - 3.2 Length The devices range in length from 4 inches to 12 inches. - 3.3 Distal Tip Style The devices are available in a variety of tip styles, including but not limited to trocar point, diamond point, and cove point. - 3.4 Proximal Tip Style The devices will have proximal tip styles including but not limited to trocar point, diamond point, check point, and round. - 3.5 Threading The devices will be provided in fully threaded, partially threaded and nonthreaded versions. - 3.6 Device Specifications Please refer to Appendix B for detailed device specifications. OrthoPro Steinman Pins and Kirschner Wires 510(k) Submission Page 8 of 11 {3}------------------------------------------------ Image /page/3/Picture/1 description: The image shows the logo for the U.S. Department of Health & Human Services. The logo consists of a stylized eagle with its wings spread, and the text "DEPARTMENT OF HEALTH & HUMAN SERVICES · USA" arranged in a circular fashion around the eagle. The eagle is depicted in black, and the text is also in black. The logo is simple and recognizable, representing the department's role in protecting the health of all Americans. Food and Drug Administration 9200 Corporate Boulevard Rockville MD 20850 JUL 13 2007 OrthoPro LLC c/o Straits Orthopaedics Inc. Mr. Christopher L. Cook Vice President Regulatory Affairs 13115 NE 4th Street, Suite 130 Vancouver, WA 98684 Re: K070555 Trade/Device Name: OrthoPro Steinman Pins and Kirschner Wires Regulation Number: 21 CFR 888.3040 Regulation Name: Smooth or threaded metallic bone fixation fastener Regulatory Class: Class II Product Code: JDW, HTY Dated: June 1. 2007 Received: June 11, 2007 Dear Mr. Cook: We have reviewed your Section 510(k) premarket notification of intent to market the device referenced above and have determined the device is substantially equivalent (for the indications for use stated in the enclosure) to legally marketed predicate devices marketed in interstate commerce prior to May 28, 1976, the enactment date of the Medical Device Amendments, or to devices that have been reclassified in accordance with the provisions of the Federal Food, Drug, and Cosmetic Act (Act) that do not require approval of a premarket approval application (PMA). You may, therefore, market the device, subject to the general controls provisions of the Act. The general controls provisions of the Act include requirements for annual registration, listing of devices, good manufacturing practice. labeling, and prohibitions against misbranding and adulteration. If your device is classified (see above) into either class II (Special Controls) or class III (PMA), it may be subject to such additional controls. Existing major regulations affecting your device can be found in the Code of Federal Regulations, Title 21, Parts 800 to 898. In addition, FDA may publish further announcements concerning your device in the Federal Register. Please be advised that FDA's issuance of a substantial equivalence determination does not mean that FDA has made a determination that your device complies with other requirements of the Act or any Federal statutes and regulations administered by other Federal agencies. You must comply with all the Act's requirements, including, but not limited to: registration and listing (21 CFR Part 807); labeling (21 CFR Part 801); good manufacturing practice requirements as set forth in the quality systems (OS) regulation (21 CFR Part 820); and if applicable, the electronic product radiation control provisions (Sections 531-542 of the Act); 21 CFR 1000-1050. {4}------------------------------------------------ ### Page 2 - Mr. Christopher L. Cook This letter will allow you to begin marketing your device as described in your Section 510(k) premarket notification. The FDA finding of substantial equivalence of your device to a legally marketed predicate device results in a classification for your device and thus, permits your device to proceed to the market. If you desire specific advice for your device on our labeling regulation (21 CFR Part 801), please contact the Center for Devices and Radiological Health's (CDRH's) Office of Compliance at (240) 276-0120. Also, please note the regulation entitled, "Misbranding by reference to premarket notification" (21CFR Part 807.97). For questions regarding postmarket surveillance, nlease contact CDRH's Office of Surveillance and Biometric's (OSB's) Division of Postmarket Surveillance at 240-276-3474. For questions regarding the reporting of device adverse events (Medical Device Reporting (MDR)), please contact the Division of Surveillance Systems at 240-276-3464. You may obtain other general information on your responsibilities under the Act from the Division of Small Manufacturers. International and Consumer Assistance at its toll-free number (800) 638-2041 or (240) 276-3150 or at its Internet address http://www.fda.gov/cdrh/industry/support/index.html. Sincerely yours, Mark A. Milburn Mark N. Melkerson Director Division of General, Restorative and Neurological Devices Office of Device Evaluation Center for Devices and Radiological Health Enclosure {5}------------------------------------------------ ## Indications for Use 4070555 510(k) Number (If Known) OrthoPro Steinman Pins and Kirschner Wires Device Name: Indications for Use: # OrthoPro Steinman Pins and Kirschner Wires Indications for Use The OrthoPro Steinman Pins and Kirschner Wires are indicated for use in fixation of bone fractures, for bone reconstructions, as guide pins for insertion of other implants or implantation through the skin so that traction may be applied to the skelctal system. Prescription Use X (Part 21 CFR 801 Subpart D Over the Counter Use (21 CFR 807 Subpart C) # (PLEASE DO NOT WRITE BELOW THIS LINE-CONTINUE ON ANOTHER PAGE IF NEEDED) Mark A. Milham (Division Sign-Off) (Division Sign of General, Restorative, Division of Neurological Devices **510(k) Number** ***_*** OrthoPro Steinman Pins and Kirschner Wires 510(k) Submission Page 4 of 11
Innolitics

Panel 1

/
Sort by
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from the tree

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...