HFB · Forceps, Biopsy, Gynecological

Obstetrics/Gynecology · 21 CFR 884.4530 · Class 1

Overview

Product CodeHFB
Device NameForceps, Biopsy, Gynecological
Regulation21 CFR 884.4530
Device ClassClass 1
Review PanelObstetrics/Gynecology

Identification

An obstetric-gynecologic specialized manual instrument is one of a group of devices used during obstetric-gynecologic procedures to perform manipulative diagnostic and surgical functions (e.g., dilating, grasping, measuring, and scraping), where structural integrity is the chief criterion of device performance. This type of device consists of the following:(1) An amniotome is an instrument used to rupture the fetal membranes. (2) A circumcision clamp is an instrument used to compress the foreskin of the penis during circumcision of a male infant. (3) An umbilical clamp is an instrument used to compress the umbilical cord. (4) A uterine curette is an instrument used to scrape and remove material from the uterus. (5) A fixed-size cervical dilator is any of a series of bougies of various sizes used to dilate the cervical os by stretching the cervix. (6) A uterine elevator is an instrument inserted into the uterus used to lift and manipulate the uterus. (7) A gynecological surgical forceps is an instrument with two blades and handles used to pull, grasp, or compress during gynecological examination. (8) A cervical cone knife is a cutting instrument used to excise and remove tissue from the cervix. (9) A gynecological cerclage needle is a looplike instrument used to suture the cervix. (10) A hook-type contraceptive intrauterine device (IUD) remover is an instrument used to remove an IUD from the uterus. (11) A gynecological fibroid screw is an instrument used to hold onto a fibroid. (12) A uterine sound is an instrument used to determine the depth of the uterus by inserting it into the uterine cavity. (13) A cytological cervical spatula is a blunt instrument used to scrape and remove cytological material from the surface of the cervix or vagina. (14) A gynecological biopsy forceps is an instrument with two blades and handles used for gynecological biopsy procedures. (15) A uterine tenaculum is a hooklike instrument used to seize and hold the cervix or fundus. (16) An internal pelvimeter is an instrument used within the vagina to measure the diameter and capacity of the pelvis. (17) A nonmetal vaginal speculum is a nonmetal instrument used to expose the interior of the vagina. (18) A fiberoptic nonmetal vaginal speculum is a nonmetal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.

Classification Rationale

(1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Special Controls

*Classification.* (1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.

Recent Cleared Devices (20 of 22)

Showing 20 most recent of 22 cleared devices.

RecordDevice NameApplicantDecision DateDecision
K011488SPIRABRUSH CX BIOPSY INSTRUMENTTrylon Corp.Feb 22, 2002SESE
K944444CIT BIOPSY PUNCHESChirurgische InstrumenteSep 29, 1995SESE
K930773SYMBIOSIS GYNECOLOGICAL BIOPSY FORCEPSSymbiosis Corp.Jul 28, 1994SESE
K933767FORCEPS, BIOPSY GYNECOLOGICAL INSTRU/BIOPSYMahe-MedizintechnikMay 26, 1994SESE
K926595OWENS BIOPSY FORCEPSOwens Industries, Inc.May 25, 1994SESE
K926527ROTO FIT BIOPSY FORCEPSThomasville Medical Assoc.Feb 25, 1994SESE
K930036THOMAS MEDICAL BIOPSY FORCEPSThomasville Medical Assoc.Feb 24, 1994SESE
K926538TISCHLER BIOPSY FORCEPSThomasville Medical Assoc.Feb 24, 1994SESE
K924224OWENS BIOPSY FORCEPSOwens Precision Systems, Inc.Feb 4, 1994SESE
K902049CROAK OVARIAN BIOPSY FORCEPGynescope Corp.Jun 7, 1990SESE
K895303EVER-SHARP BIOPSY FORCEPSSouthwest Medical Mfg., Inc.Jan 16, 1990SESE
K891043ROTO FIT BIOPSY FORCEPSZinnanti Surgical Instruments, Inc.Mar 22, 1989SESE
K891034TISCHLER BIOPSY FORCEPSZinnanti Surgical Instruments, Inc.Mar 17, 1989SESE
K891027ZSI BIOPSY FORCEPSZinnanti Surgical Instruments, Inc.Mar 17, 1989SESE
K890380CERVICAL BIOPSY FORCEPSKinetic Medical ProductsFeb 27, 1989SESE
K852357GYNE-SHEAR CERVICAL BIOPSY INSTRUMENT W/DISPIS TIPGyneco, Inc.Jul 5, 1985SESE
K851110GAYLOR-THOMS UTERINE BIOPSY FORCEPS 1810-144 PCS.The Huxley Instrument Corp.Apr 8, 1985SESE
K842112TISCHLER CERVICAL BIOPSY PUNCH FORCEPSJ. Sklar Mfg. Co., Inc.Jul 3, 1984SESE
K840352CIN-SHEARRoland J. Zwick, Inc.Apr 5, 1984SESE
K820519BIOPSERAdvanced Biomedical InstrumentsApr 29, 1982SESE

Top Applicants

Innolitics
Guidance Recalls

Panel 1

/
Ready

Predicate graph will load when search results are available.

Embedding visualization will load when search results are available.

PDF viewer will load when search results are available.

Loading panels...

Select an item from Submissions

Click any panel, subpart, regulation, product code, or device to see details here.

Section Matches

Results will appear here.

Product Code Matches

Results will appear here.

Special Control Matches

Results will appear here.

Loading collections...