SINGLE CHANNEL BALLOON CANNULA
Device Facts
| Record ID | K974801 |
|---|---|
| Device Name | SINGLE CHANNEL BALLOON CANNULA |
| Applicant | Conkin Surgical Instruments , Ltd. |
| Product Code | HDP · Obstetrics/Gynecology |
| Decision Date | Jul 9, 1998 |
| Decision | SESE |
| Submission Type | Traditional |
| Regulation | 21 CFR 884.4530 |
| Device Class | Class 2 |
Indications for Use
The SINGLE CHANNEL BALLOON CANNULA is to be used with the VALTCHEV UTERINE MOBILIZER, models VUM-4 or VUM-5, for mobilization of the uterus and injection of dye. It is indicated for use during those procedures requiring manipulation of the uterus such as a minilap, laparoscopic tubal occlusion or diagnostic and operative laparoscopy. It is also an efficient intrauterine injector that effectively seals the internal cervical os against the cervical backflow of fluid during its injection through the device's central lumen and as such can be used in laparoscopic tubal patency studies and, in selected patients, for such procedures as hysterosalpingography.
Device Story
Single Channel Balloon Cannula functions as accessory to Valtchev Uterine Mobilizer (models VUM-4/VUM-5). Device features central lumen for dye injection and balloon component to seal internal cervical os, preventing fluid backflow. Used by physicians during gynecological procedures (laparoscopy, minilap, hysterosalpingography) to facilitate uterine mobilization and intrauterine fluid delivery. Benefits include improved visualization and procedural efficiency during tubal patency studies and diagnostic/operative interventions.
Clinical Evidence
No clinical data provided; bench testing only.
Technological Characteristics
Single channel cannula with integrated balloon for cervical sealing. Designed for use with Valtchev Uterine Mobilizer. Mechanical device; no software or electronic components.
Indications for Use
Indicated for patients undergoing procedures requiring uterine manipulation, including minilap, laparoscopic tubal occlusion, diagnostic/operative laparoscopy, laparoscopic tubal patency studies, and hysterosalpingography.
Regulatory Classification
Identification
An obstetric-gynecologic specialized manual instrument is one of a group of devices used during obstetric-gynecologic procedures to perform manipulative diagnostic and surgical functions (e.g., dilating, grasping, measuring, and scraping), where structural integrity is the chief criterion of device performance. This type of device consists of the following:(1) An amniotome is an instrument used to rupture the fetal membranes. (2) A circumcision clamp is an instrument used to compress the foreskin of the penis during circumcision of a male infant. (3) An umbilical clamp is an instrument used to compress the umbilical cord. (4) A uterine curette is an instrument used to scrape and remove material from the uterus. (5) A fixed-size cervical dilator is any of a series of bougies of various sizes used to dilate the cervical os by stretching the cervix. (6) A uterine elevator is an instrument inserted into the uterus used to lift and manipulate the uterus. (7) A gynecological surgical forceps is an instrument with two blades and handles used to pull, grasp, or compress during gynecological examination. (8) A cervical cone knife is a cutting instrument used to excise and remove tissue from the cervix. (9) A gynecological cerclage needle is a looplike instrument used to suture the cervix. (10) A hook-type contraceptive intrauterine device (IUD) remover is an instrument used to remove an IUD from the uterus. (11) A gynecological fibroid screw is an instrument used to hold onto a fibroid. (12) A uterine sound is an instrument used to determine the depth of the uterus by inserting it into the uterine cavity. (13) A cytological cervical spatula is a blunt instrument used to scrape and remove cytological material from the surface of the cervix or vagina. (14) A gynecological biopsy forceps is an instrument with two blades and handles used for gynecological biopsy procedures. (15) A uterine tenaculum is a hooklike instrument used to seize and hold the cervix or fundus. (16) An internal pelvimeter is an instrument used within the vagina to measure the diameter and capacity of the pelvis. (17) A nonmetal vaginal speculum is a nonmetal instrument used to expose the interior of the vagina. (18) A fiberoptic nonmetal vaginal speculum is a nonmetal instrument, with fiberoptic light, used to expose and illuminate the interior of the vagina.
Special Controls
*Classification.* (1) Class II (special controls). The device, when it is an umbilical clamp with or without a cutter, a uterine tenaculum which is sterile and does not use suction and is intended for single use, a nonmetal vaginal speculum, or a fiberoptic nonmetal vaginal speculum, is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to the limitations in § 884.9.(2) Class I for the amniotome, uterine curette, cervical dilator (fixed-size bougies), cerclage needle, IUD remover, uterine sound, and gynecological biopsy forceps. The devices subject to this paragraph (b)(2) are exempt from the premarket notification procedures in subpart E of part 807 of this chapter, subject to the limitations in § 884.9.
Reference Devices
- VALTCHEV UTERINE MOBILIZER (VUM-4 or VUM-5)
Related Devices
- K093556 — VCARE DX · Conmed Corporation · Mar 12, 2010
- K240364 — RELIEEV Uterine Manipulator Injector (CUMI 5.0) · Li Medical Corporation , Ltd. · Oct 16, 2024
- K212505 — DUMI ManipulatOR · The O R Company Pty, Ltd. · Jan 10, 2022
- K040238 — SOFTSEAL HSG CATHETER · Modern Medical Equipment Mfg., Ltd. · Jun 22, 2004
- K020292 — UTERINE INJECTOR · Catheter Research, Inc. · Apr 17, 2002