- AnesthesiologyReview Panel
- CardiovascularReview Panel
- ChemistryReview Panel
- DentalReview Panel
- Ear, Nose, ThroatReview Panel
- Gastroenterology and UrologyReview Panel
- General HospitalReview Panel
- HematologyReview Panel
- ImmunologyReview Panel
- MicrobiologyReview Panel
- NeurologyReview Panel
- Obstetrical and GynecologicalReview Panel
- Assisted Reproduction DevicesCFR Sub-Part
- MQENeedle, Assisted Reproduction2Product Code
- MQFCatheter, Assisted Reproduction2Product Code
- MQGAccessory, Assisted Reproduction2Product Code
- MQHMicrotools, Assisted Reproduction (Pipettes)2Product Code
- MQIMicrotool Fabrication, Assisted Reproduction2Product Code
- MQJMicromanipulators And Microinjectors, Assisted Reproduction2Product Code
- MQKLabware, Assisted Reproduction2Product Code
- MQLMedia, Reproductive2Product Code
- MRXSystem, Assisted Reproduction Laser2Product Code
- MTWSystem, Water, Reproduction, Assisted, And Purification2Product Code
- MTXMicroscope And Microscope Accessories, Reproduction, Assisted1Product Code
- NNBNeedle, Reproduction, Assisted, Reprocessed2Product Code
- PBHEmbryo Image Assessment System, Assisted Reproduction2Product Code
- OYOCulture, Intravaginal, Assisted Reproduction2Product Code
- PUBAccessory, Assisted Reproduction, Exempt2Product Code
- PUCMicrotools, Assisted Reproduction (Pipettes), Exempt2Product Code
- PUDLabware, Assisted Reproduction, Exempt2Product Code
- QKHAssisted Reproduction Laminar Flow Workstation2Product Code
- QKIMedia, Reproductive, Exempt2Product Code
- Cardiovascular Monitoring DevicesCFR Sub-Part
- Cardiovascular Prosthetic DevicesCFR Sub-Part
- Clinical Chemistry Test SystemsCFR Sub-Part
- Diagnostic DevicesCFR Sub-Part
- MiscellaneousMiscellaneous
- Obstetrical and Gynecological Diagnostic DevicesCFR Sub-Part
- Obstetrical and Gynecological Monitoring DevicesCFR Sub-Part
- Obstetrical and Gynecological Prosthetic DevicesCFR Sub-Part
- Obstetrical and Gynecological Surgical DevicesCFR Sub-Part
- Obstetrical and Gynecological Therapeutic DevicesCFR Sub-Part
- Physical Medicine Prosthetic DevicesCFR Sub-Part
- Prosthetic DevicesCFR Sub-Part
- Therapeutic DevicesCFR Sub-Part
- OphthalmicReview Panel
- OrthopedicReview Panel
- PathologyReview Panel
- Physical MedicineReview Panel
- RadiologyReview Panel
- General and Plastic SurgeryReview Panel
- ToxicologyReview Panel
- Medical GeneticsReview Panel
- UnknownReview Panel
Catheter, Assisted Reproduction
- Page Type
- Product Code
- Regulation Medical Specialty
- Obstetrical and Gynecological
- Review Panel
- Obstetrical and Gynecological
- Submission Type
- 510(K)
- Device Classification
- Class 2
- Regulation Number
- 884.6110
- GMP Exempt?
- No
- Summary Malfunction Reporting
- Eligible
- Implanted Device
- No
- Life-Sustain/Support Device
- No
- Third Party Review
- Third Party Eligible
- MAUDE Alerts
- View and Sign Up For MAUDE Alerts
CFR § 884.6110 Assisted reproduction catheters
§ 884.6110 Assisted reproduction catheters.
(a) Identification. Assisted reproduction catheters are devices used in in vitro fertilization (IVF), gamete intrafallopian transfer (GIFT), or other assisted reproduction procedures to introduce or remove gametes, zygote(s), preembryo(s), and/or embryo(s) into or from the body. This generic type of device may include catheters, cannulae, introducers, dilators, sheaths, stylets, and component parts.
(b) Classification. Class II (special controls) (mouse embryo assay information, endotoxin testing, sterilization validation, design specifications, labeling requirements, biocompatibility testing, and clinical testing).